Mains EMI filter: sources, common-mode choke, damping and CISPR 16 receiver

LISN (50 µH+5 Ω)∥50 Ω bridge + PFC or flyback switching node Cp CX1 CX2 common-mode choke CY CY L N PE
The filter sits between the mains, here the measurement LISN, and the converter bridge. The X capacitors and the choke leakage stop the differential current, which flows between line and neutral; the choke and the Y capacitors stop the common-mode current, which leaves the switching node, crosses the parasitic capacitance Cp to the heatsink and earth, and returns through both lines together.

Introduction

A switching converter sends part of its fast currents back to the mains. Electromagnetic compatibility standards measure this disturbance between 150 kHz and 30 MHz with a stabilising network, the LISN, which puts a known impedance between each line and earth and feeds the voltage to a receiver; the receiver reads it with a 9 kHz bandwidth and two detectors, quasi-peak and average, and compares it with two limits. The mains filter is there to stay below those limits with margin.

The disturbance has two modes. The differential one is the input current ripple: it flows between line and neutral, and it is stopped by X capacitors and an inductance in series with the lines, usually the choke leakage. The common-mode one comes from the voltage edges of the switching node: the capacitance between the drain and the earthed heatsink carries current to earth, which returns through both lines in phase; it is stopped by the common-mode choke, a large impedance for this current, and by the Y capacitors to earth, which however carry 50 Hz leakage current and are limited by the safety standard.

The tool starts from the converter: a boost PFC with the engine of the PFC calculator, a bulk-fed flyback, or a generic trapezoidal source. It computes the unfiltered noise and the attenuation needed in each mode, chooses the choke on TDK T38 or VAC VITROPERM cores with their measured complex permeability, sizes the Y capacitors with the leakage limit, checks damping and the filter’s effect on the converter loop, and finally measures the spectrum with a simulated receiver, quasi-peak and average, against the chosen standard.

WhatFormula
LISN\( Z_{LISN} = (j\omega\,50\,\mu\text{H} + 5\,\Omega)\parallel 50\,\Omega \)
Voltages on the two lines\( V_L = V_{CM} + \tfrac12 V_{DM},\quad V_N = V_{CM} – \tfrac12 V_{DM} \)
Harmonics of a piecewise-linear waveform\( c_n = \dfrac{1}{T}\sum_k \Big[\Big(\dfrac{j\,x(t)}{\omega_n}+\dfrac{m_k}{\omega_n^2}\Big)e^{-j\omega_n t}\Big]_{t_k}^{t_{k+1}} \)
Choke impedance\( Z = j\omega N^2 \Lambda(f) = \omega N^2\Lambda”(f) + j\omega N^2\Lambda'(f),\quad \Lambda = A_L\,\dfrac{\mu’-j\mu”}{\mu_i} \)
Filter corner\( f_0 = \min_f\; f\cdot 10^{-A(f)/(40\,n_{stadi})} \)
Leakage current\( I_{disp} = 2\pi f_l\,V_{ac,max}\,C_Y \)
Optimum R–C damping\( n = \dfrac{C_d}{C},\quad R_d = R_0\sqrt{\dfrac{(2+n)(4+3n)}{2n^2(4+n)}},\quad R_0=\sqrt{L/C} \)
Quasi-peak\( \dfrac{dq}{dt} = \dfrac{e-q}{\tau_c}\Big|_{e>q} – \dfrac{q}{\tau_s},\quad \tau_c = 1\ \text{ms},\ \tau_s = 160\ \text{ms} \)

Card 1 — Noise source and standard

Standard
PFC
Flyback
Generic source
Capacitor after the bridge
Switching and parasitics

The source waveforms are those of each switching period along the line cycle: for the PFC the inductor current and drain voltage of the PFC calculator, with discontinuous conduction near the zero; for the flyback the primary current and drain voltage, with the bulk discharging between line peaks and the bridge conducting only to recharge it; for the generic source a constant trapezoid. The edges have the rise and fall times you enter: they decide the spectrum above a few megahertz.

Without a filter the graph shows the peak of the harmonics on the LISN, total and for each mode. From the difference with the limits, plus the margin, comes the attenuation needed; dividing it by 40 dB/decade per stage gives the highest corner frequency the filter may have. In the flyback the differential current reaches the mains only while the bridge conducts; the common-mode one always passes.

Limits: tables from the Tekbox guide “Pre-Compliance Conducted Emission Measurements”, which reports them from the standards; in the bands where the limit falls, it falls linearly with the logarithm of frequency. For the class and edition applying to your appliance the official text prevails.

Card 2 — Differential filter

The differential filter is an LC low-pass per stage: the X capacitance between the lines and the series inductance, which for the line-to-neutral current is twice that of one line. The common-mode choke provides it almost for free with its leakage, one or two percent of the common-mode inductance, which does not saturate because its flux runs in air; if it is not enough, an inductor per line is added. With two stages the slope becomes 80 dB/decade, but each stage has its own resonance.

Leakage depends on how the choke is wound and must be measured on the part, with one winding shorted. X capacitors carry a 50 Hz reactive current that lowers the power factor at light load, and the graph also shows how much the filter attenuates the common mode: both curves should be read together with the card 1 spectrum.

Card 3 — Common-mode choke and Y capacitors

Y capacitors

For the common-mode current, flowing the same way in both windings, the choke is an inductor with the full core permeability; for the line current, which goes and returns, the fluxes cancel and the core does not saturate. Above a few hundred kilohertz, however, the permeability of these materials becomes complex: the real part falls and the imaginary part rises, and the choke behaves more like a resistor than an inductor. The tool uses the µ′ and µ″ curves measured by the manufacturers, taken from the datasheet graphs: TDK’s for T38 ferrite and VAC’s for VITROPERM 500F nanocrystalline, fitted to each core so as to match the catalogue AL at 10 and 100 kHz.

Above a few megahertz the winding capacitance Cw decides: the choke resonates and becomes a capacitor. A single layer, well separated sections and start far from finish keep it low. The automatic choice tries cores from the smallest, each with the minimum turns that meet the margin, with a wire sized on the line current and at most two layers.

The Y capacitors return the common-mode current to earth close to the converter, but at 50 Hz they pass leakage current: the limit depends on the safety standard and the kind of appliance. The values in the list come from the comparison table between IEC 60335-1 and IEC 62368-1 published by COSEL; for class II appliances and for cases not listed, enter the value from your standard.

Core model check against a measurement

VAC publishes the insertion loss, in a 50 Ω system, of a choke on a 25 × 20 × 10 VITROPERM 500F core with 2 × 28 turns, wound two ways with Cw = 21 pF and 4 pF. The lines are the tool’s model with the W622 core and the same turns, the dots are read from figure 4 of the VAC catalogue. Between 30 kHz and 4 MHz the difference is 2–3 dB; higher up the measurement shows lead resonances the model does not have.

Card 4 — Damping and the Middlebrook criterion

A lossless LC filter has an impedance peak at its resonance, and seen from the converter that peak matters. For a converter regulating its output, the input behaves like a negative resistance −V²/P: if the filter output impedance comes close to it, the system can oscillate. This is the Middlebrook criterion, the same as in the input filter calculator.

The PFC is a different case: its current loop makes it draw a current proportional to voltage, so at these frequencies it is not a negative resistance. However the current-loop plant, from duty cycle to inductor current, sees the source in series with the boost inductor: with a filter in front it becomes Vo/(sL + Zs), with Zs the filter impedance in parallel with Cin. The tool recomputes the loop gain with that factor and shows how much margin is lost.

The most used damping is an R–C branch across the last X: Cd blocks DC and line frequency, Rd dissipates at resonance. Erickson and Maksimović’s formula (Fundamentals of Power Electronics, chapter 10) gives the Rd that minimises the peak for a given ratio n; the tool checks it by sweeping Rd on the whole filter, with the LISN, the Y capacitors and Cin. At 50 Hz Cd still carries a reactive current, and Rd dissipates it.

Card 5 — Filtered spectrum, CISPR 16 receiver

BandQuasi-peak marginAverage margin
Time-domain check of the filter network
fDM, phasorsDM, time domainCM, phasorsCM, time domain

The receiver does what a real instrument does. For each measurement frequency it takes the LISN voltage over a whole line cycle, brings it to baseband, passes it through an intermediate-frequency filter with 9 kHz bandwidth at −6 dB and takes its envelope. The quasi-peak detector charges with 1 ms and discharges with 160 ms, the CISPR 16-1-1 values for band B; the average is the mean value of the envelope; for a continuous sinusoid both read its RMS value. Both lines are measured and the worse one counts.

This matters because PFC noise is not stationary: harmonic amplitude follows the line cycle, and in CrM the frequency sweeps, so each harmonic crosses the receiver band only for an instant. Quasi-peak and average weigh this differently from peak, and with variable frequency the average drops a lot. With fixed frequency the tool measures on the harmonics themselves, where the maximum is; with variable frequency on a grid of 300 frequencies.

The second table is the physical check of the network: the filter, the LISN and the capacitance Cp simulated in time with a Runge–Kutta integrator, driven by the switching current and voltage of a period near the line peak, and the harmonics taken from the simulation compared with the phasor ones. To do it in time the core becomes a constant inductance and resistance, taken at 150 kHz, in both methods.

Model limits: the LISN is the CISPR 16-1-2 one, (50 µH + 5 Ω) ∥ 50 Ω, as described by Schwarzbeck; the quasi-peak meter time constant is not modelled, because I could not find its value in a verifiable source, and the reported quasi-peak is the maximum of the detector output; drain ringing after turn-off, bridge diode capacitance, coupling between components and lead resonances are not included. The bench measurement remains the last word.