PCB trace width and via current calculator: IPC-2221 and IPC-2152
Introduction
A printed circuit trace is a flat, thin conductor, and the current heats it. How much it heats depends on the cross-section, but also on how it gives its heat away: to the air on an outer face, to the laminate inside the board, to nearby copper planes if there are any. Hence the usual question: how wide must the trace be for this current? The tool answers with two methods, which often disagree, and shows by how much.
The first is the IPC-2221 formula, the one behind almost every online calculator: a curve fitted to charts from the 1950s. The second is the model of Douglas Brooks and Johannes Adam, derived from the data of the newer standard, IPC-2152. The tool then works out the trace resistance and voltage drop, the cross-section and resistance of the vias, and what happens with a short current pulse, up to melting.
| What | Formula |
|---|---|
| IPC-2221 | \( I = k\,\Delta T^{0.44}A^{0.725},\qquad k = 0.048\ \text{outer},\ 0.024\ \text{inner},\ A\ \text{in mil}^2 \) |
| Brooks–Adam | \( \Delta T = c\,I^{\,e_I}W^{\,e_W}t^{\,e_t},\qquad \text{outer}: c = 215.3,\ e_I = 2,\ e_W = -1.15,\ e_t = -1,\ W, t\ \text{in mil} \) |
| Resistance | \( R = \rho_{20}\,[1+\alpha(T-20)]\,\dfrac{L}{W\,t},\qquad \rho_{20} = 1.7241\cdot10^{-8}\ \Omega\,\text{m},\ \alpha = 0.00393\ \text{K}^{-1} \) |
| Via cross-section | \( A_v = \pi\,(D+t_p)\,t_p,\qquad R_{th} = \dfrac{H}{k_{Cu}A_v},\ k_{Cu} = 401\ \text{W/(m K)} \) |
| Adiabatic pulse | \( I^2 t = K^2 S^2 \ln\dfrac{\theta_f+\beta}{\theta_i+\beta},\qquad K = 226\ \text{A}\sqrt{\text{s}}/\text{mm}^2,\ \beta = 234.5\ ^\circ\text{C} \) |
| Onderdonk | \( I = A_{cm}\sqrt{\dfrac{\log_{10}\!\left(1+\dfrac{T_m-T_a}{234+T_a}\right)}{33\,t}},\qquad A_{cm}\ \text{in circular mil},\ T_m = 1083\ ^\circ\text{C} \) |
| Preece | \( I = 10\,244\ d^{\,1.5},\qquad d\ \text{in inches, round wire of equal cross-section} \) |
Copper thickness is given in ounces per square foot: 1 oz is 1.378 mil, that is 35 µm. W is the trace width, t the copper thickness, L the length, D the finished hole diameter, tp the wall copper, H the board thickness, S the cross-section in mm².
Card 1 — The trace
You choose how much the trace may heat above ambient. Ten kelvin is a cautious choice for almost everything; twenty or thirty are fine on short traces or where the board is warm anyway. The adopted width is the larger of the two, and resistance, drop and power come from it, with the copper at working temperature.
The two formulas do not say the same thing. IPC-2221 comes from old charts, carried over from the earlier IPC-D-275 standard, and halves the allowed current for inner layers; the new IPC-2152 standard redid the measurements and found the opposite: inner traces, embedded in a laminate that conducts heat better than air, run cooler than outer ones. On outer traces the IPC-2152 currents are about 25 % lower than IPC-2221’s, so the trace comes out somewhat wider.
Both apply to an isolated trace, in still air, with no nearby copper planes. A ground plane under the trace, even on the other side of the board, cools it a lot: in that case both are conservative. Short traces ending on large pads are cooler than long ones, because heat also escapes from the ends.
The Brooks and Adam model
Brooks and Adam fitted the IPC-2152 curves with a power law. For outer layers a single formula is enough, valid for every thickness; for inner ones the constant and the exponents change with the copper weight, and for 0.5 and 3 oz the constant also changes slightly with width: the tool interpolates between the published values. This is why on inner layers the method holds only for 0.5, 1, 2 and 3 oz. Width and thickness are in mil: the paper does not say so explicitly, but the authors’ two numerical examples only work out this way. A 2 oz outer trace 100 mil wide carrying 10 A gives 39 K against the paper’s “just under 40”, and the same trace inside gives 32 K against 33.
Card 2 — Vias
The via copper is only what is plated on the hole wall, twenty or twenty-five microns: its cross-section is the circumference times the wall thickness. IPC-2152 asks for vias with at least the same copper cross-section as the trace they connect, and the tool counts how many are needed. For a single via, at equal copper thickness, this gives the Brooks and Graves rule: the finished hole must be at least a third of the trace width.
In practice vias run cooler than the trace feeding them. Brooks and Adam measured and simulated it: with the same copper cross-section the via always stays below the trace temperature, because the surrounding laminate carries heat away better than air. The via temperature is set by the connected traces, not by the current. This is why the cross-section rule is conservative, and several small vias in parallel work as well as a large one.
The thermal resistance is for thermal vias under a hot component, for example a regulator’s exposed pad: it is that of the copper cylinder through the board thickness. The laminate and the pads add other paths, so the real value is somewhat different; the copper value tells how many vias are needed to reach a few kelvin per watt.
The average wall copper required by IPC-6012 is 20 µm for class 2 and 25 µm for class 3. Plating also adds copper to the outer faces: a board ordered as “1 oz” often starts from 0.5 oz and reaches about 33 µm after plating.
Card 3 — Pulses and melting
An inrush at switch-on, the charging of input capacitors, a short circuit before the fuse blows: for a short time the trace carries much more current than usual. If the time is short the heat has no time to escape, and all the energy heats the copper: this is the adiabatic case, the same used to check cables under short circuit. The tool uses the card 1 trace and starts from its working temperature, unless you type another one.
Copper resistance rises with temperature, and the adiabatic equation accounts for it through β: this is why the heating accelerates. Onderdonk does the same calculation up to copper melting, at 1083 °C, and Preece gives the steady-state melting current, measured on wires hanging in air at the end of the nineteenth century. The tool works out the time to melt with Onderdonk and with the adiabatic equation: they are two independently derived formulas, and the badge shows how well they agree.
The adiabatic calculation holds as long as cooling does not matter. On a printed circuit board the laminate starts removing heat in less than a second and a half; Brooks and Adam estimate that Onderdonk holds up to four or five seconds. For longer durations the card 1 steady-state temperature rise applies. A trace used as a fuse is not reliable: the melting current changes with the real copper thickness, with plating and with whatever surrounds it.
Checks: IPC-2221 gives 11.8, 53.8 and 108.9 mil for 1, 3 and 5 A on 1 oz outer with 10 K, as in the NextPCB reference table. Brooks–Adam gives 39 K and 32 K on the authors’ examples (2 oz, 100 mil, 10 A, outer and inner), and 176 K for 1 oz, 100 mil and 15 A, against about 180 in the melting article. For the same trace Onderdonk gives 2.6 s at 15 A as in the article, the adiabatic equation 2.6 s and Preece 15 A. Sources: Advanced Circuits, Trace Width Calculator (IPC-2221 and data range); NextPCB, PCB Trace Width Calculator: IPC-2221; D. G. Brooks, J. Adam, Trace Currents and Temperatures Revisited, April 2015; D. Brooks, J. Adam, Vias Are Cooler Than We Think, Signal Integrity Journal, 2019; D. Brooks, D. Graves, Current Carrying Capacity of Vias, 2003; D. Brooks, Onderdonk’s and Preece’s Equations: How Do They Compare?, PCD&F; The Adiabatic Equation and k Factor for Cable Thermal Withstand (IEC 60364-5-54); JLCPCB, Understanding IPC-6012 Standards; NCAB, How Do You Calculate Finished Copper?; Engineering ToolBox, Copper – Thermal Conductivity vs. Temperature.