Valve amplifier output transformer calculator: single-ended and push-pull

~ Vs rs valve Rp Lp C Ld Rs′ RL′ = n²RL everything referred to the primary; ideal n : 1 transformer after RL′
The output transformer equivalent circuit, all referred to the primary. At low frequencies the primary inductance Lp counts, shunting the signal to ground; at high frequencies the leakage inductance Ld, in series with the load, and the winding capacitance C, in parallel, count. In between only the copper resistances remain. The valve’s internal resistance rs decides how much each one weighs.

Introduction

The output transformer matches the loudspeaker, a few ohms, to the valve, which wants a few thousand ohms, and carries the whole signal from 20 Hz to 20 kHz. It is the part that sets the bandwidth and much of the amplifier’s sound, and it is also the one that people who build their own amplifier pay most for or wind themselves. The trade-offs are always the same: many turns for inductance and to avoid saturating at low frequencies, few turns and interleaved sections for little leakage and capacitance at high frequencies, and everything has to fit in the lamination window.

The tool starts from the valve operating point, taken from the datasheet or typed in, chooses the EI lamination, works out the turns, the gap for single-ended, the wires and the sections, and from there the primary inductance, the leakage, the capacitance, the frequency response and the losses. Laminations, steels and wires are those of the EI laminated transformer calculator; the amplifier power supply is in the tube amplifier power transformer calculator.

WhatFormula
Turns ratio\( n = \dfrac{N_p}{N_s} = \sqrt{\dfrac{R_a}{R_L}},\qquad V_{pk} = \sqrt{2\,P\,R_a} \)
Flux density\( B_{ac} = \dfrac{V_{pk}}{2\pi f\,N_p\,A_{fe}},\qquad A_{fe} = a\,s\,k_f \)
Required primary inductance\( L_p \ge \dfrac{r_s \parallel R_a}{2\pi f_L} \)
Gap (SE)\( B_{dc} = \dfrac{\mu_0 N_p I_0}{g + l_{fe}/\mu_r(B_{dc})},\qquad B_{dc} + B_{ac} \le B_{max} \)
Primary inductance\( L_p = \dfrac{\mu_0 N_p^2 A_{fe}}{g + l_{fe}/\mu_a(B)} \)
Leakage\( L_d = \dfrac{\mu_0 N_p^2}{b_w}\displaystyle\int \mathrm{MLT}(x)\,m(x)^2\,dx \)
Capacitance\( C = \displaystyle\sum \dfrac{\varepsilon_0\varepsilon_r\,\mathrm{MLT}\,b_w}{d}\cdot\dfrac{\Delta_a^2+\Delta_a\Delta_b+\Delta_b^2}{3} \)
Self-resonance\( f_r = \dfrac{1}{2\pi\sqrt{L_p\,C}} \)

a is the centre leg width, s the stack height, kf the stacking factor, lfe the mean magnetic path, bw the usable bobbin length, MLT the mean length of a turn at distance x from the centre leg. m(x) is the magnetomotive force across the winding thickness in units of Np·Ip; Δa and Δb are the voltage differences between two facing layers at their two ends, as fractions of the primary voltage.

Card 1 — Valves and load

Targets

Everything starts from three datasheet numbers: the anode load Ra (in push-pull Raa, plate to plate), the power and the quiescent current. The turns ratio comes from the load, the primary voltage from the power, the single-ended gap from the current. The valve’s internal resistance, the rs of the equivalent circuit, decides how much primary inductance is needed: the low cut-off falls where the reactance of Lp equals rs in parallel with Ra.

This is why a triode like the 300B, with an ra of 700 Ω, makes do with a few henries, while a pentode without feedback, with an ra of tens of kilohms, wants many more: the source is almost a current generator and the whole low-frequency load falls on Lp. With feedback the resistance seen by the transformer drops; if it is known, set the library to “by hand” and type it in rs.

The targets are two frequencies and a level. Lp is calculated at a low level, 1 W by default, because at low flux density the steel permeability is lower and the inductance is at its minimum there. Full power is asked down to fsat: below it, the core may saturate. Push-pull has no gap and every milliampere of imbalance between the two valves adds DC flux: the tool allows for it in the turns when it can, and flags it when that is not enough.

The library holds the typical operating points printed in the datasheets: EL84, EL34, 6V6GT, 6L6GC in single-ended and push-pull, KT88 in triode push-pull, 300B in single-ended and 2A3 both ways. Ultralinear points are not there, because they need taps on the primary, which this tool does not design.

Card 2 — Core and windings

Wire and insulation
SectionTurnsLayers × turnsWireThicknessMLTR

The turns count is the smallest that meets two conditions together: at full power and at fsat the flux density stays below Bmax, and at low level and at fL the inductance reaches the required value. In single-ended the valve’s DC magnetises the core: the tool picks the smallest gap that leaves room for the AC below Bmax, and more gap means less inductance and so more turns. The total gap is that of the magnetic path, which crosses it twice: in an EI the spacer between the Es and the Is is half of it.

With the automatic lamination the tool tries laminations from the smallest, with the stack from one to two times the centre leg, and keeps the first one where the windings fill at most 85 % of the window, a margin for hand winding; if none does, the first one they fit in. The wire follows the current density: up to 0.5 mm one wire, above that several side by side. The primary sections are in series; the secondary ones in parallel, each with all the turns, or in series. The window drawing is to scale.

Interleaving the sections is the lever on leakage: with P-S the whole magnetomotive force builds up in one zone, with P-S-P-S-P it is split into four smaller zones and the leakage drops by about ten times; with the EL34 in push-pull on an EI96 it goes from 73 to 7 mH. The price is the space lost in the insulation between sections and more facing surfaces between primary and secondary. The total capacitance may rise or fall, because thinner sections also have fewer layers with a large voltage between them: the tool adds them all up.

How leakage and capacitance are calculated

Leakage comes from the magnetic field energy in the winding thickness, with Dowell’s one-dimensional model: the magnetomotive force rises linearly in the primary sections, falls in the secondary ones and is constant in the insulation; its square is integrated, weighted by the turn length at that distance from the centre leg. The integral is in closed form, and the tool checks it with an independent numerical integration: that is the badge under the drawing.

Capacitance comes from the electrostatic energy between facing surfaces: two adjacent layers are a parallel-plate capacitor one turn long and one bobbin wide, and the voltage between them varies linearly from one end to the other, because the layers are wound back and forth. The primary goes from zero, at the cold end, to full voltage; in push-pull the centre tap is grounded and the ends sit at plus and minus half. The secondary and the core are at zero potential. Everything is referred to the primary as a single C.

Card 3 — Response and losses

The solid curve is at low level, with Lp calculated at that level. The dashed one is at full power: the source voltage is the one that gives full power on the load at 1 kHz, and at each frequency Lp follows the flux density that voltage produces. Above the knee of the B–H curve the permeability collapses and the low cut-off rises: it is low-frequency saturation seen from the response.

At the top, leakage and capacitance make a second-order filter. With a triode the low source resistance damps it and the curve rolls off gently; with a pentode without feedback the damping comes only from the load and a peak may appear. A real loudspeaker is not a resistor, and above a few kilohertz its impedance rises: the real peak may be higher than this.

Copper losses use the RMS currents at full power and the copper at the stated temperature; iron losses use the steel table at 50 Hz and full voltage, the worst case. The insertion loss is the one at mid frequencies with an ideal source: it is the power the copper takes from the loudspeaker. The self-resonance fr is that of Lp with C: it is the number to look for on the bench, measuring the primary impedance with the secondary open.

Card 4 — Low-frequency saturation

Flux density is inversely proportional to frequency: at the same voltage, at 15 Hz it is twice that at 30 Hz. The first graph follows it in the real circuit, with the primary voltage dropping when Lp starts to fall short. In single-ended the DC sits underneath, held steady by the gap. The resulting full-power frequency may sit a little above fsat: the turns are calculated with the ideal voltage √(2PRa), while in the circuit the primary also has to supply the drop in the secondary copper.

With a low-resistance source, a triode, the primary voltage stays full all the way down and the flux density climbs until it saturates. With a pentode the source is almost a current generator and as soon as Lp falls the voltage falls with it: the core stops on the knee of the curve, but the response collapses and distortion rises. In both cases the practical limit is the frequency below which full power cannot be asked; at those frequencies music usually has little energy, and a high-pass filter before the output stage protects the transformer.

The second graph is the other side: at low level the flux density is small, the silicon steel permeability is lower and Lp drops. This is why Lp is calculated at low level: with a triode that is where the bass response is worst. Below 0.1 T the steel table ends and the tool holds the permeability at 0.1 T: the curve is flat there, and the real Lp is a little lower.

Model limits: the permeability is the amplitude permeability measured at 50 Hz without DC, on the Epstein frame; in single-ended the incremental permeability under DC is lower, and the tool shows the share of reluctance in the gap, which makes it unimportant when it is high. The gap has no fringing correction, because I found no verified source for EI laminations: the real one is adjusted on the bench by measuring Lp. The capacitance uses a single εr and puts all of C on the primary. Copper eddy-current losses at high frequencies are not calculated: at 20 kHz the skin depth in copper is about 0.47 mm, close to the thickest wire, and at those frequencies music carries little power.

Checks: for a symmetrical S-P-S winding, 1000 turns, 30 mm bobbin, sections of 1, 2 and 1 mm with 0.2 mm between them, the closed-form leakage, the numerical integration and McLyman’s formula 17-3 with the mean MLT all give 2.974 mH. The capacitance between the layers of a single winding matches the classical formula 4/3·C0·(n − 1)/n² for n layers wound back and forth. The response is calculated with the impedance ladder and checked with the nodal matrix. Sources: Tata Steel, Typical data for SURA M400-50A and the M470, M530 and M700 sheets of the same series; Elektrisola, Technical data for enamelled copper wire based on IEC 60317; C. W. T. McLyman, Transformer and Inductor Design Handbook, 4th ed., CRC Press, 2011, ch. 17; P. L. Dowell, Effects of eddy currents in transformer windings, Proc. IEE, vol. 113, no. 8, 1966; the valve datasheets, cited in card 1; the laminations of the EI laminated transformer calculator.