LLC Resonant Converter Design Calculator: Tank, Transformer and Frequency Loop
Introduction
The LLC is the isolated converter for medium and high power after a PFC: the MOSFETs turn on at zero voltage, the output diodes turn off at zero current near resonance, and the transformer works with bipolar flux. It does not regulate with the duty cycle, fixed at 50 %, but with frequency: above resonance the gain drops, below it rises up to a peak, and past the peak the tank turns capacitive and soft switching is lost. Designing an LLC means choosing the tank so that the whole range of input voltage and load stays on the right side of the curve.
The tool covers the half bridge and the full bridge, the centre-tapped and the bridge rectifier, with diodes or synchronous rectifiers. The tank is designed with the first-harmonic approximation (FHA), which is the method of every application note; then a cycle-by-cycle simulation of the real circuit, with dead times and Coss, shows where the FHA is wrong: the true operating frequencies, zero-voltage switching, the currents. The transformer and the resonant inductor are wound on the N87 cores of the inductor calculator. There is no simple averaged model for the loop: the tool measures the stage gain on the simulation, as a network analyser would, and designs the TL431 on it with the method of the control loop calculator.
| What | Formula |
|---|---|
| FHA gain | \( M = \dfrac{1}{\sqrt{\left(1+\dfrac{1}{L_n}-\dfrac{1}{L_n f_n^2}\right)^2+Q^2\left(f_n-\dfrac{1}{f_n}\right)^2}} \) |
| Normalised quantities | \( f_r = \dfrac{1}{2\pi\sqrt{L_r C_r}},\quad f_n = \dfrac{f}{f_r},\quad L_n = \dfrac{L_m}{L_r},\quad Q = \dfrac{\sqrt{L_r/C_r}}{R_{ac}} \) |
| Reflected load | \( R_{ac} = \dfrac{8\,n^2}{\pi^2}\,R_o \) |
| Output | \( V_{out}+V_F = M\,\dfrac{k\,V_{in}}{n},\quad k = \tfrac{1}{2}\ \text{half bridge},\ k = 1\ \text{full bridge} \) |
| Zero-voltage switching | \( \dfrac{n\,V_x}{4\,L_m f} \ge \dfrac{2\,C_{oss} V_{in}}{t_d} \) |
Card 1 — Specifications and resonant tank
| Vin | M | f with FHA | real-circuit f | Tank RMS I | Swing on Cr | ZVS | |
|---|---|---|---|---|---|---|---|
The turns ratio puts resonance at nominal Vin: there M = 1 and the converter runs at its best point, with the rectifier current turning off by itself at zero. At minimum Vin a gain above 1 is needed, hence a frequency below resonance; at maximum Vin a gain below 1, above it. Ln sets the curve shape: a low value gives a high peak and a narrow frequency range, but more magnetising current. Q depends on load: more load, lower peak. If you leave Q empty, the tool takes the highest value for which, with the overload margin, the peak still reaches the minimum-Vin gain.
The FHA treats the rectifier current as a sinusoid, and it is exact only at resonance. Below resonance the current stops before the end of the half period, the true gain is higher than the FHA one and the true operating frequency higher; above, the opposite. The table and the orange squares in the graph come from the simulation of the real circuit, with dead times, Coss and the rectifier drop; the last column says whether the MOSFETs turn on at zero voltage.
Card 2 — Transformer and resonant inductor
| Winding | N | Conductor | Irms | Rdc | FR a f | Loss |
|---|
The transformer works with bipolar flux: while the rectifier conducts, the magnetising inductance sees ±n·Vx, and peak B is highest at the lowest frequency, that is at minimum Vin. Primary turns come from there; Lm is obtained with the gap, from TDK’s AL values with fringing as in the inductor tool. The real currents come from the simulation at minimum Vin and full load, and copper losses are computed with Dowell’s model on their harmonics. With the centre tap each half of the secondary conducts for half a period and carries its share of current.
Integrated leakage or separate inductor
With integrated leakage the transformer also acts as Lr: primary and secondary are wound on two side-by-side sections of the bobbin, and the spacing between sections sets the leakage. One part is saved, but leakage cannot be computed well before winding: it is measured on the primary with the secondary shorted, and adjusted. With a separate inductor Lr is easy to design and measure, and the transformer can have interleaved primary and secondary, with lower copper loss; its small leakage adds to Lr.
Card 3 — Frequency loop
| Part | Position | Computed | Standard |
|---|
The LLC controller turns the optocoupler current into frequency: more current, higher frequency, lower gain. The VCO gain is your controller’s, in kHz per volt on the pull-up node. The stage, from frequency to output voltage, has no simple averaged model like PWM: the output voltage depends on the envelope of the resonant current, and its response has poles that move with the operating point. So the tool measures it: it modulates the frequency of the simulation at twelve frequencies and reads the output response, as a network analyser on the bench would. The K factor sizes the TL431 on that measurement.
The physical check of the measurement is the static slope: the change in Vout with frequency, taken from the real circuit at two nearby frequencies, must match the lowest measured point.
Card 4 — Switching check
| Quantity | Calculation | Closed-loop simulation |
|---|
The first graph is a zoom over three periods at nominal Vin. During the dead time the tank current, which at that instant is almost all magnetising current, carries the switching node from one rail to the other: if it gets there before the next MOSFET turns on, switching is at zero voltage. The rectifier current is the difference between the tank current and the magnetising current, referred to the secondary: at resonance it turns off exactly at the end of the half period.
The table compares the calculation with the closed-loop simulation: the operating frequency, the tank RMS current according to the FHA, the residual voltage at turn-on and the loop gain at fc, measured by injecting a signal into the closed loop. Here the comparison is with the open-loop measurement of card 3, not with an independent model: it checks the interpolation and the compensator. The second graph is a load step, with the frequency moving to bring the output back to its value.
In the simulation the MOSFETs are switches with their Coss on the node, constant; diodes have a fixed drop and synchronous rectifiers behave like diodes with their resistance; all the leakage is in Lr. Start-up, no-load operation and short-circuit protection are not simulated.