IGBT Module Power Cycling Lifetime Calculator: Rainflow, Miner

Tj t ΔTj of the mission ripple at the output frequency ton idle: the junction falls back towards the air
Junction temperature in a repeating mission. The large cycle comes from alternating work and idle, with the heatsink warming and cooling; on top of it sits the ripple at the output frequency, because the IGBT conducts for only half a period. Each cycle fatigues the solder joints and the bond wires, and rainflow counting separates them by swing ΔTj, temperature and heating time ton.

Introduction

An IGBT module does not fail because it is hot, but because it heats and cools. Silicon, the aluminium of the bond wires, the copper and the substrate ceramic expand differently, and each temperature cycle leaves a small plastic strain at the joints. After a number of cycles that depends mostly on the swing ΔTj, a wire lifts off or the solder under the chip cracks, the thermal resistance rises and the module’s life ends. Manufacturers’ power cycling tests measure this number of cycles; lifetime models interpolate it.

The tool starts from the datasheet thermal networks, like the heatsink and thermal transient calculator, simulates a repeating piecewise mission, with each segment’s mean losses and the ripple at the output frequency, counts the junction temperature cycles with the rainflow method and adds up the damage with Miner’s rule. There are three lifetime models with published coefficients: LESIT, CIPS 2008 and Semikron Danfoss’ 2024 model, plus one by hand.

WhatFormula
LESIT\( N_f = A\,\Delta T_j^{\,\alpha}\,\exp\!\left(\dfrac{E_a}{k_B T_m}\right),\quad A = 302\,500,\ \alpha = -5{,}039,\ E_a = 9{,}89\cdot10^{-20}\,\text{J} \)
CIPS 2008\( N_f = K\,\Delta T_j^{\,\beta_1}\exp\!\left(\dfrac{\beta_2}{T_{j,min}}\right) t_{on}^{\,\beta_3} I^{\,\beta_4} V^{\,\beta_5} D^{\,\beta_6} \)
Semikron Danfoss\( N_f = A_0 A_1^{\beta}\,\Delta T_j^{\,\alpha-\beta}\exp\!\left(\dfrac{E_a}{k_B T_{jm}}\right)\dfrac{C+t_{on}^{\,\gamma}}{C+2^{\gamma}}\,k_{thickness},\quad \beta = e^{-(\Delta T_j-T_0)/\lambda} \)
Miner damage\( D = \sum_i \dfrac{n_i}{N_{f,i}},\qquad life = \dfrac{1}{D}\ \ \text{missions} \)
Temperatures\( T_m = T_{jm} = \dfrac{T_{j,max}+T_{j,min}}{2},\qquad all in kelvin in the exponentials \)

Card 1 — Module and heatsink

Heatsink
ChipΣ riDatasheet RthRthCHτiCauer ladder, from the junction

The thermal network is that of the heatsink calculator: the datasheet Zth in Foster form, converted to the equivalent Cauer ladder, then the RthCH interface and the heatsink as one node with resistance and capacity. In a three-phase inverter the same heatsink carries six switches with the same mean losses: for one of them the heatsink warms as if it had six times the resistance and a sixth of the capacity, with the same time constant.

The graph shows the two time scales. Up to a tenth of a second the module counts, and that is where the ripple at the output frequency comes from; from a few seconds up the heatsink counts, and that is where the slow cycles between work and idle come from. These are the two kinds of cycle the count separates.

The library holds only modules whose ri, τi networks I found printed in the datasheet. In Infineon datasheets from a few years ago the τi are 0.01, 0.02, 0.05 and 0.1 s for every module and only the ri change: they are given as printed. The FF300R12KE4P gives the Zth up to the heatsink, with the interface material pre-applied.

Card 2 — Mission

Segment 1
Segment 2
Segment 3
Segment 4
Segment 5
Segment 6
Use
SegmentDurationfMaximum IGBT TjIGBT rippleMaximum diode TjDiode ripple

The mission is a repeating sequence of constant-power segments: a motor start, running, braking, idle. Each segment takes the mean losses of IGBT and diode, the inverter output frequency and the air temperature; losses can come from the heatsink calculator or from a conduction and switching loss calculation. With f = 0 the power is constant, as in a DC converter.

The tool computes the temperature in two steps. With the mean losses it finds the slow history of the mission already at steady state, heatsink included, exactly with the network modes. Then for each segment with f > 0 it computes the periodic steady state over the output period, with the IGBT conducting in the positive half-cycle and the diode in the negative one, and derives the ripple. At low frequencies, at a motor start, the ripple is large: at 5 Hz the chip has time to heat and cool in each half-cycle, and that is often where the module’s life is spent.

Card 3 — Cycles and lifetime

ChipCycles per mission: slow · lineDamage per missionfrom slow cyclesLife in missionsLife
CycleΔTjTjtonPer missionNfShare of damage
ModelIGBT lifeDiode life

Rainflow counting, in the three-point version of ASTM E1049, splits the temperature history into closed cycles: each cycle has its swing, its minimum, mean and maximum temperature and the duration of its rising leg, which serves as ton. The slow history is rotated to start at its maximum, so every cycle of the repeating mission closes. Ripple cycles are counted over one period and multiplied by the number of periods, each at the slow temperature of its moment.

Each cycle uses up 1/Nf of the life, and Miner’s rule adds them regardless of order. The matrix shows where the damage is: almost always in a few large cycles, even when the small ones run into millions. The model table gives the same mission with every model: differences of an order of magnitude are normal, and they show how uncertain a lifetime estimate is.

The three models

LESIT comes from the power cycling tests of the European project of the same name on 1990s traction modules: it depends only on ΔTj and the mean temperature. For today’s modules it is pessimistic. CIPS 2008, by Bayerer and colleagues, adds the heating time, the current per bond foot, the voltage class and the wire diameter; these are not in datasheets and have to be asked from the manufacturer, so the tool does not invent them. The ton−0.463 term grows without limit for short ripple cycles.

Semikron Danfoss’ model (application note AN 21-001, 2024) is the most recent: three parameter sets for copper-baseplate modules, modules without baseplate and modules with sintered chips, an increase of cycles at low ΔTj measured with inverter tests, a ton dependency normalised to 2 s and a chip thickness factor. The note also gives the data ranges: ΔTj from 30 to 120 K, ton from 0.04 to 60 s, mean temperature from 333 to 400 K; the tool reports the share of damage coming from cycles outside these ranges. It is valid for Semikron Danfoss modules; for others it is a reference.

Card 4 — Sensitivity

The first graph changes only the heatsink resistance, with the same thermal capacity; the second shifts the air temperature of every segment. The heatsink affects the slow cycles and the mean temperature, not the ripple, which depends on the module: if the damage comes from low-frequency ripple, a larger heatsink helps little, and it pays to reduce the start-up current or raise the minimum output frequency.

Checks: the rainflow count reproduces the ASTM E1049 example (ranges 3, 4, 6, 8 and 9 with 0.5, 1.5, 0.5, 1 and 0.5 cycles) and matches the four-point method, which the tool uses as an independent check. The Semikron Danfoss model gives 878,000 cycles at ΔTj = 60 K between 40 and 100 °C and 262,000 between 90 and 150 °C, against about 880,000 and 260,000 in the note. LESIT and CIPS 2008, with the coefficients of figure 1 of Brunko and colleagues, give 5.1·104 and 1.5·105 cycles at 80 K under the conditions of that figure, like its curves. The mission temperature is checked with an independent integration of the network equations. Not included: the temperature dependence of the losses, the degradation that raises the thermal resistance towards end of life, the statistical spread of life, which the models give as a mean value or at a given failure probability. Sources: A. Brunko, W. Holzke, H. Groke, B. Orlik, N. Kaminski, Model-Based Condition Monitoring of Power Semiconductor Devices in Wind Turbines, EPE’19 ECCE Europe, 2019; Semikron Danfoss, Power Cycle Model for IGBT Product Lines, AN 21-001, rev. 02, 2024; M. Held, P. Jacob, G. Nicoletti, P. Scacco, M. Poech, Fast power cycling test of IGBT modules in traction application, PEDS, 1997; R. Bayerer, T. Herrmann, T. Licht, J. Lutz, M. Feller, Model for power cycling lifetime of IGBT modules – various factors influencing lifetime, CIPS, 2008; ASTM E1049-85, Standard Practices for Cycle Counting in Fatigue Analysis; Infineon, AN2015-10; the module datasheets, cited in card 1.