Heatsink and Thermal Transient Calculator: Zth and Tj Peak

Pj (t) Tj r1 C1 r2 C2 … rn Cn Tc Rcs Rsp Th Chs R0 Ta + other packages, same chain junction–case Foster, from the datasheet
The thermal network the tool solves. Each chip has its junction–case Foster network, taken from the datasheet; the case discharges through the interface Rcs and the spreading resistance Rsp into the heatsink base, which has a thermal capacity Chs and a resistance R0 to the air. Temperatures are the voltages, powers the currents.

Introduction

With the mean power and the thermal resistances in series you get the mean junction temperature. But an IGBT in a 50 Hz inverter conducts for half a period and rests for the other half, a MOSFET in a soft starter takes a few seconds of overload, a diode sees a current pulse at switch-on: the junction follows these changes, because its time constant is milliseconds, while the heatsink’s is minutes. The peak that matters for Tj,max sits above the mean, sometimes by a lot.

The tool takes the junction–case Zth from the datasheet in Foster network form, computes the finned heatsink from its geometry, in forced or natural convection, and puts the two together for several devices on the same heatsink. Losses are an input: for a MOSFET they can be estimated with the MOSFET calculator, for a converter with the one on the phase-shifted full bridge or the PFC.

WhatFormula
Thermal impedance\( Z_{th}(t) = \sum_i r_i\left(1-e^{-t/\tau_i}\right),\qquad \tau_i = r_i C_i \)
Cauer ladder\( Z_{th}(s) = \sum_i \dfrac{r_i}{1+s\tau_i} = \cfrac{1}{sC_1+\cfrac{1}{R_1+\cfrac{1}{sC_2+\cdots+\cfrac{1}{sC_n+\cfrac{1}{R_n}}}}} \)
Junction, Foster connection\( T_j(t) = T_c(t) + \sum_i x_i(t),\qquad \tau_i\,\dfrac{dx_i}{dt} = r_i\,P(t) – x_i \)
Pulse train\( Z_{th}(t_p, T) = \sum_i r_i\,\dfrac{1-e^{-t_p/\tau_i}}{1-e^{-T/\tau_i}},\qquad D = t_p/T \)
Case and heatsink\( q_c = \dfrac{T_c-T_h}{R_{cs}+R_{sp}},\qquad C_{hs}\dfrac{dT_h}{dt} = \sum q_c – \dfrac{T_h-T_a}{R_0} \)
Fins\( R_{hs} = \dfrac{1}{h\,(A_{base}+N\eta A_{fin})},\qquad \eta = \dfrac{\tanh mH_f}{mH_f},\quad m=\sqrt{\dfrac{2h}{k\,t_f}},\qquad R_0 = R_{hs}+\dfrac{t_b}{kWL} \)
Forced convection\( Nu_b = \left[\left(\dfrac{Re_b^*Pr}{2}\right)^{-3}+\left(0{,}664\sqrt{Re_b^*}\,Pr^{0{,}33}\sqrt{1+\dfrac{3{,}65}{\sqrt{Re_b^*}}}\right)^{-3}\right]^{-0{,}33},\quad Re_b^* = \dfrac{\rho V b}{\mu}\,\dfrac{b}{L} \)
Natural convection\( Nu_b = \dfrac{Ra_b}{24}\left(1-e^{-35/Ra_b}\right)^{0{,}75},\qquad Ra_b = \dfrac{\rho^2 g\beta c_p\,b^4\,\Delta T}{\mu k L} \)
Spreading\( R_{sp} = \dfrac{\sqrt{A_p}-\sqrt{A_s}}{k\sqrt{\pi A_p A_s}}\cdot\dfrac{\lambda k A_p R_0+\tanh\lambda t}{1+\lambda k A_p R_0\tanh\lambda t},\qquad \lambda = \dfrac{\pi^{3/2}}{\sqrt{A_p}}+\dfrac{1}{\sqrt{A_s}} \)

Card 1 — Devices and thermal impedance

ChipΣ riDatasheet Rth(j-c)CellsτiJunction steady state, 5 τmaxCauer ladder capacities, from the junction

In the datasheet the Zth(j-c) appears twice: as a graph versus pulse duration, and as a table of ri, τi pairs. The table is the Foster network that produced the graph: with it the tool rebuilds the junction temperature for any power profile. The first τ, tens of microseconds, are the silicon and the solder; the last, tenths of a second, the copper base of the package. After five times the longest τ the junction is at steady state, and only the sum of the ri counts, which must match the datasheet Rth(j-c): the table shows it, and it is the first check that the numbers were copied correctly.

The second graph is what datasheets call “transient thermal impedance” with constant duty-cycle curves: compare it with the datasheet figure to check the network is the right one. The curves come from the closed-form steady-state pulse-train formula.

Library devices and Zth by hand

The library contains only devices whose ri, τi table I found printed in the datasheet: Infineon IGBTs with diode in TO-247 and TO-220 and Infineon SiC MOSFETs in TO-247. Many recent datasheets give only the graph. For the others use “Zth by hand”: ri in K/W and τi in seconds, separated by semicolons. Some manufacturers give the Cauer network instead of the Foster one, with capacitances in J/K: that has to be converted, not copied. If the datasheet only gives the graph, a Foster network can be obtained by fitting three or four terms to the single-pulse curve.

The footprint is the metal part of the package resting on the heatsink, and it feeds the spreading resistance. The case–heatsink Rth depends on the mounting: 0.24 K/W is the typical value of a TO-247 on a flat greased surface, without insulator. With an insulator, essential when several packages at different potentials share a heatsink, use the one from its datasheet.

Card 2 — Finned heatsink

Material
Air
PackageFootprint AsCell ApRspRcsMean P

The heatsink is computed from its geometry, not from the catalogue curve. Heat passes through the base, rises into the fins, which give it to the air with a coefficient h; the fin is not all at the base temperature, and the efficiency η says how much of its surface really works. Tall thin fins have a low efficiency: beyond a certain height they no longer help.

In forced convection h comes from the Teertstra, Yovanovich and Culham correlation for channels between parallel fins, in the form given by Simons; the velocity is the mean in the channels, and the resistance already includes the air heating, so the reference is the inlet air. More fins give more surface but narrower channels, and the graph shows where it stops paying off. In natural convection h comes from Elenbaas’ correlation for vertical plates, and depends on the temperature rise: the tool iterates until h and ΔT agree. There the optimum fin gap is wide, usually between 6 and 10 mm, and the tool shows it next to the chosen one: a dense heatsink gets worse. Altitude lowers the air density and with it the heat transfer.

Spreading, several packages and thermal capacity

A small package on a wide base heats the area beneath it more: that is the spreading resistance, computed with Lee’s formula. With several packages the tool divides the base into equal cells, one per package, giving each the area Ap/N and the resistance N·Rhs; the base thickness is increased by 20 %, as Lee suggests to account for the fins. The model does not know where the packages sit: two near the edge or side by side run hotter than the average cell says.

The thermal capacity is that of the whole heatsink, base and fins, lumped into one node. That holds as long as power changes much faster than its time constant, as for a 50 Hz line. For slow profiles, tens of seconds, the heatsink does not heat uniformly and the one-node model is approximate.

Model checks: with the geometry of Lee’s example (Ap = 0.01 m², As = 6.25 cm², t = 1.3 mm, k = 200, R0 = 1 K/W) the spreading comes out at 0.657 K/W against the article’s 0.66. The 50 × 50 mm heatsink of Simons’ figure 2, at 2.5 m/s, matches within 5 % over all heights and from 10 to 30 fins if the fins are 0.5 mm thick and k = 150 W/(m·K); the article does not give thickness and material, and reading the graph has its own error. Elenbaas’ correlation stays within 4 % of Bar-Cohen and Rohsenow’s for isothermal plates from Ra = 1 to 2000. Air properties come from Sutherland’s law with White’s coefficients and the ideal gas; at 300 K they agree with Incropera’s table A.4.

Card 3 — Power profile and temperatures

ChipMean PMaximum TjMean TjSwingMaximum TcMargin

Chip powers are entered in card 1, and their meaning depends on the profile. In the single pulse and the train P is the power during the pulse. In the line period P is the mean loss over the period, which the tool spreads over each chip’s conducting half-cycle with the chosen shape: sin² for resistive conduction, like a MOSFET, |sin| for a constant drop, like a diode; an IGBT is in between and you pick whichever weighs more. In the piecewise profile P is 100 % and each segment gives a percentage of it.

For repeating profiles the tool computes the periodic steady state exactly: the network is split into its eigenmodes, each first order, and with piecewise-constant power each mode updates with an exponential, so the state at the start of the period is found without simulating minutes of warm-up. The first graph shows two periods at steady state, the second how you get there from cold. The allowed R0 is the base–air resistance at which the hottest junction reaches exactly Tj,max minus the margin, with the same capacity and spreading: it says how much the heatsink can shrink, or how much it has to grow.

The swing is the difference between the junction maximum and minimum over the window. It is the number that sets the thermal-cycling life of the bond wires and the solder: at the same mean temperature, a low-frequency inverter, which swings the junction by tens of kelvin, ages much faster than one at 50 Hz.

Chip to case: Cauer or Foster

The Foster network reproduces the Zth measured with the case held fixed, but its internal nodes are not physical temperatures, and resting it on a heatsink is not rigorous: Infineon’s application note AN2015-10 says so plainly, and adds that the Cauer network does not fully avoid the error either. Using the Foster network as it is, as in its equation Tj = Tc(t) + P ∗ Zth, power reaches the case at the same instant it is generated in the chip, and crosses the interface and the spreading with no filtering: over the line period the case swings like the power. That is the pessimistic bound.

So by default the tool converts the Foster network into the Cauer ladder with exactly the same Zth: the continued fraction of the impedance, computed in exact rational arithmetic. On a fixed case both give the same junction; on the heatsink, heat reaches the case filtered by the package capacities, as really happens. The card 1 table shows the ladder capacities: when the last datasheet τ is long and its r small, the last capacity comes out large, tens of J/K, more than the copper of a TO-247, and it is probably the test fixture. With air its weight is small, because the heatsink time constant, tens of seconds to minutes, is much longer than the device’s; with a water-cooled plate the two get closer and you need the Zth measured on the real assembly.

Independent physical check: the network equations are also integrated with fourth-order Runge-Kutta, with a step small compared with the shortest τ, starting from the same state; the badge compares the states at the end of each segment and the junction peak, and for periodic profiles checks that the state returns to itself after one period. The pulse train on a fixed case matches the closed-form formula in the table. Not included: the temperature dependence of the losses, the position of the packages on the base, the change of h during the transient in natural convection. Sources: Infineon, Transient thermal measurements and thermal equivalent circuit models, AN2015-10, rev. 1.1, 2018; R. E. Simons, Estimating Parallel Plate-Fin Heat Sink Thermal Resistance, Electronics Cooling, 2003; R. E. Simons, Estimating Natural Convection Heat Transfer for Arrays of Vertical Parallel Flat Plates, Electronics Cooling, 2002; S. Lee, Calculating Spreading Resistance in Heat Sinks, Electronics Cooling, 1998; P. Teertstra, M. M. Yovanovich, J. R. Culham, Analytical forced convection modeling of plate fin heat sinks, IEEE SEMI-THERM, 1999; W. Elenbaas, Heat dissipation of parallel plates by free convection, Physica, 1942; A. Bar-Cohen, W. M. Rohsenow, Thermally optimum spacing of vertical, natural convection cooled, parallel plates, Journal of Heat Transfer, 1984; F. M. White, Viscous Fluid Flow; F. P. Incropera, D. P. DeWitt, T. L. Bergman, A. S. Lavine, Fundamentals of Heat and Mass Transfer, tables A.1 and A.4; the device datasheets, cited in card 1.