ELEC · Practical Guide 11 — Calculate the Faraday current ceiling with Dataset Expression
Use four quantities with declared units to calculate the Faraday ceiling for chlorine generation. Publish the resulting scalar with its units.
ELEC project · Practical GX-TXT guide 11 of 16.
Reproduction target: GX-TXT DEV112-P013. The original screenshots and recorded results document the historical ELEC session. A rerun on P013 has yet to be verified.
Module: Dataset Expression
Learning objective: Calculate the current ceiling with Dataset Expression
Prerequisites / input: Four literal quantities with units
Expected output: Canonical unit-aware current-ceiling scalar
Scientific background and reference results
The theoretical chlorine-production ceiling provides a scale for comparing conditional rates. Produce it with explicit units in Dataset Expression, rather than copying an untraceable number into a worksheet. This is the historical private Expression 1.0.3 configuration.
Step-by-step procedure
- Open Dataset Expression in the Session copy. Prepare a scalar expression with formula
M*I/(2*F*V)and output unitg*m^-3*min^-1. Disable coordinate retention: the result is a scalar rather than a time series. - Create four literal bindings:
M=70.906 [g/mol],I=0.12 [A],F=96485.33212 [A*s/mol],V=0.0002 [m^3]. Check each symbol, value and unit before evaluation. - The one-row primary source
hal_fig3e_no_loss_source_rate_operator_verifiedprovides configuration context: its value does not enter the formula. Do not add it to force a nonexistent numerical relationship. - Apply and evaluate the expression, check units and a value approximately
13.228000276898461 g*m^-3*min^-1, then publish with a new ID. Historical product ishal_chlorine_current_ceiling_pmax_01, variablepmax. - Under Scientific Worksheet → Data → Bind Dataset…, choose that Dataset and variable
pmax, destinationY, first row1, maximum1. The worksheet thus uses the canonical Expression output rather than becoming a second producer of the ceiling.


Native units convert seconds and minutes: do not multiply by 60 manually. The ceiling is theoretical and conditional on entered current and volume; P013 is NOT_RUN.
Working materials
Figure 3 digitized datasets (CSV) · Model and constraint datasets (CSV)
Other steps of this project
- ELEC 02 — Model hierarchy: effective kinetics, transfer and identifiability
- ELEC 03 — From fits to constraints: what does the chlorine balance reveal?
- ELEC 01 — What does the experiment measure? Nitrogen, chlorine and pH
- ELEC 07 — Sources, conclusions and tests that could distinguish the mechanisms
- ELEC 04 — Kinetics, speciation and transport: from local reaction to reactor response
- ELEC 06 — Where the numbers came from: GX-TXT, GNU Octave and reproducibility