ELEC · Practical Guide 11 — Calculate the Faraday current ceiling with Dataset Expression

by Giux Electrochemistry, GX-TXT 2 min read

Use four quantities with declared units to calculate the Faraday ceiling for chlorine generation. Publish the resulting scalar with its units.

ELEC project · Practical GX-TXT guide 11 of 16.

Reproduction target: GX-TXT DEV112-P013. The original screenshots and recorded results document the historical ELEC session. A rerun on P013 has yet to be verified.

Module: Dataset Expression

Learning objective: Calculate the current ceiling with Dataset Expression

Prerequisites / input: Four literal quantities with units

Expected output: Canonical unit-aware current-ceiling scalar

Scientific background and reference results

The theoretical chlorine-production ceiling provides a scale for comparing conditional rates. Produce it with explicit units in Dataset Expression, rather than copying an untraceable number into a worksheet. This is the historical private Expression 1.0.3 configuration.

Step-by-step procedure

  1. Open Dataset Expression in the Session copy. Prepare a scalar expression with formula M*I/(2*F*V) and output unit g*m^-3*min^-1. Disable coordinate retention: the result is a scalar rather than a time series.
  2. Create four literal bindings: M=70.906 [g/mol], I=0.12 [A], F=96485.33212 [A*s/mol], V=0.0002 [m^3]. Check each symbol, value and unit before evaluation.
  3. The one-row primary source hal_fig3e_no_loss_source_rate_operator_verified provides configuration context: its value does not enter the formula. Do not add it to force a nonexistent numerical relationship.
  4. Apply and evaluate the expression, check units and a value approximately 13.228000276898461 g*m^-3*min^-1, then publish with a new ID. Historical product is hal_chlorine_current_ceiling_pmax_01, variable pmax.
  5. Under Scientific Worksheet → Data → Bind Dataset…, choose that Dataset and variable pmax, destination Y, first row 1, maximum 1. The worksheet thus uses the canonical Expression output rather than becoming a second producer of the ceiling.
H_P Expression configuration
Historical Expression controls for `M*f*I/(2*F*V)`: includes f and illustrates the interface, rather than the pmax configuration without f. · Retained original GX-TXT/ELEC documentation image; source and hash in metadata. Atrashkevich et al. (2025), DOI 10.1016/j.watres.2025.123732 for any publication pixels. View at full resolution
Budget workbook
The historical workbook uses Dataset-bound results; the current ceiling originates in Dataset Expression. · Retained original GX-TXT/ELEC documentation image; source and hash in metadata. Atrashkevich et al. (2025), DOI 10.1016/j.watres.2025.123732 for any publication pixels. View at full resolution

Native units convert seconds and minutes: do not multiply by 60 manually. The ceiling is theoretical and conditional on entered current and volume; P013 is NOT_RUN.

Working materials

Figure 3 digitized datasets (CSV) · Model and constraint datasets (CSV)

#Dataset Expression #Electrochemistry #Faraday's law #GX-TXT