ELEC · Practical Guide 04 — Digitize the chlorine control and compare pH traces

by Giux Electrochemistry, GX-TXT 2 min read

Digitize the nitrogen-free total chlorine control, then compare the two bulk pH traces at 100 rpm while preserving the observations and units of each run.

ELEC project · Practical GX-TXT guide 4 of 16.

Reproduction target: GX-TXT DEV112-P013. The original screenshots and recorded results document the historical ELEC session. A rerun on P013 has yet to be verified.

Module: Curve Digitalizer / Curve Viewer

Learning objective: Digitize the chlorine control and compare pH

Prerequisites / input: Panel e raster and two pH Datasets

Expected output: Chlorine control Dataset and pH comparison graph

Scientific background and reference results

The nitrogen-free control and the two pH traces answer different questions. The former describes total chlorine; the latter are pH observations with and without N. Even when coordinates share time, keep concentrations, chemical bases and experimental conditions distinct.

Step-by-step procedure

  1. In Viewers → Curve Digitalizer open hal_fig3_page20_300dpi and create a separate configuration for panel e. Under Calibration set X 0–60 min, Y 0–400 mg Cl₂/L, both linear, with Y direction Upward (Cartesian). Select its frame’s four corners using Set BL, Set BR, Set TL and Set TR; accept and verify independent ticks.
  2. Under Curves → New curve select nine clear open-circle centres in the nitrogen-free control. Avoid bar ends. Check the overlay visually and use Publish → Publish selected calibrations with a new ID. Historical product hal_fig3e_0rpm_no_added_n_total_chlorine.measurement_1.curves contains nine points.
Nine control points
Reopened historical configuration: markers identify chlorine-control centres, rather than bar ends. · Retained original GX-TXT/ELEC documentation image; source and hash in metadata. Atrashkevich et al. (2025), DOI 10.1016/j.watres.2025.123732 for any publication pixels. View at full resolution
  1. For the pH comparison use the two already acquired curves hal_fig3b_100rpm_bulk_ph_n_present_01.measurement_1.curves and hal_fig3b_100rpm_bulk_ph_no_added_n_01.measurement_1.curves. Under Dataset → Variables check x min with semantic role elapsed_time, and y pH with unit 1; where appropriate save the schema with Save Schema. This does not change values.
  2. Under Curve Viewer → New 2D, use Add source… → Choose canonical Dataset to add both sources, selecting x/y and scatter. Give nitrogen-present and nitrogen-free series distinct legends, without connecting points as interpolated trajectories. Each historical series contains ten centres.
  3. Use Save Workspace, then Publish Plot → Create new Graph with a new ID and save again. Historical graph plot.dataset.xy/p0038 displays 10 + 10 points without lines. The curves describe observed pH at selected times; they do not directly measure formation or gas-loss rates.
Published pH comparison
Historical workspace p0038 reopened, with two discrete series and the published graph reference. · Retained original GX-TXT/ELEC documentation image; source and hash in metadata. Atrashkevich et al. (2025), DOI 10.1016/j.watres.2025.123732 for any publication pixels. View at full resolution

The chlorine control can separately enter a transferred model with its assumptions stated. This exercise creates no new experiment and P013 reproduction remains NOT_RUN.

Working materials

Figure 3 digitized datasets (CSV)

#chlorine #Curve Digitalizer #Electrochemistry #GX-TXT #pH

Other steps of this project