ELEC · Practical Guide 04 — Digitize the chlorine control and compare pH traces
Digitize the nitrogen-free total chlorine control, then compare the two bulk pH traces at 100 rpm while preserving the observations and units of each run.
ELEC project · Practical GX-TXT guide 4 of 16.
Reproduction target: GX-TXT DEV112-P013. The original screenshots and recorded results document the historical ELEC session. A rerun on P013 has yet to be verified.
Module: Curve Digitalizer / Curve Viewer
Learning objective: Digitize the chlorine control and compare pH
Prerequisites / input: Panel e raster and two pH Datasets
Expected output: Chlorine control Dataset and pH comparison graph
Scientific background and reference results
The nitrogen-free control and the two pH traces answer different questions. The former describes total chlorine; the latter are pH observations with and without N. Even when coordinates share time, keep concentrations, chemical bases and experimental conditions distinct.
Step-by-step procedure
- In Viewers → Curve Digitalizer open
hal_fig3_page20_300dpiand create a separate configuration for panel e. Under Calibration set X0–60 min, Y0–400 mg Cl₂/L, bothlinear, with Y direction Upward (Cartesian). Select its frame’s four corners using Set BL, Set BR, Set TL and Set TR; accept and verify independent ticks. - Under Curves → New curve select nine clear open-circle centres in the nitrogen-free control. Avoid bar ends. Check the overlay visually and use Publish → Publish selected calibrations with a new ID. Historical product
hal_fig3e_0rpm_no_added_n_total_chlorine.measurement_1.curvescontains nine points.

- For the pH comparison use the two already acquired curves
hal_fig3b_100rpm_bulk_ph_n_present_01.measurement_1.curvesandhal_fig3b_100rpm_bulk_ph_no_added_n_01.measurement_1.curves. Under Dataset → Variables check xminwith semantic roleelapsed_time, and y pH with unit1; where appropriate save the schema with Save Schema. This does not change values. - Under Curve Viewer → New 2D, use Add source… → Choose canonical Dataset to add both sources, selecting x/y and
scatter. Give nitrogen-present and nitrogen-free series distinct legends, without connecting points as interpolated trajectories. Each historical series contains ten centres. - Use Save Workspace, then Publish Plot → Create new Graph with a new ID and save again. Historical graph
plot.dataset.xy/p0038displays 10 + 10 points without lines. The curves describe observed pH at selected times; they do not directly measure formation or gas-loss rates.

The chlorine control can separately enter a transferred model with its assumptions stated. This exercise creates no new experiment and P013 reproduction remains NOT_RUN.
Working materials
Other steps of this project
- ELEC 02 — Model hierarchy: effective kinetics, transfer and identifiability
- ELEC 03 — From fits to constraints: what does the chlorine balance reveal?
- ELEC 01 — What does the experiment measure? Nitrogen, chlorine and pH
- ELEC 07 — Sources, conclusions and tests that could distinguish the mechanisms
- ELEC 04 — Kinetics, speciation and transport: from local reaction to reactor response
- ELEC 06 — Where the numbers came from: GX-TXT, GNU Octave and reproducibility