ELEC · Practical Guide 10 — Evaluate chlorine transfer with fixed parameters

by Giux Electrochemistry, GX-TXT 2 min read

Evaluate two fixed-parameter chlorine predictions at the actual sampling times of the nitrogen-free 100 rpm control.

ELEC project · Practical GX-TXT guide 10 of 16.

Reproduction target: GX-TXT DEV112-P013. The original screenshots and recorded results document the historical ELEC session. A rerun on P013 has yet to be verified.

Module: Curve Fitter

Learning objective: Evaluate a chlorine transfer with fixed parameters

Prerequisites / input: Normalized 100 rpm chlorine Dataset

Expected output: Two fixed-parameter prediction Datasets

Scientific background and reference results

A formula can be evaluated at Dataset times without estimating new parameters. Here H_P and H_L are hypotheses transferred to chlorine at 100 rpm, rather than new chlorine fits or direct measurements of gross production.

Step-by-step procedure

  1. In Curve Fitter, use Add Dataset curve to choose hal_no_n_100rpm_transfer_current_bound_01, the normalized Dataset for the same stirring speed. Select x and y1 in g/m^3.
  2. Set all rows, Output domain source and disable translations. Values will be evaluated at original times, which are not stored chronologically.
  3. Under Safe formula enter f*pmax*x*exprel(-k*x), declaring f [1], k [1/min], pmax [g*m^-3*min^-1], x [min] and response [g/m^3]. For H_P set f=0.40786705489089287, k=0; for H_L use f=0.5124310708631978, k=0.16632963477398346. In both cases pmax=13.228000276898461 [g*m^-3*min^-1].
  4. Set Fixed=True for all three effective parameters. Historical numerical bounds were -Inf/+Inf: separately verify physical conditions 0≤f≤1 and k≥0; do not assume the bounds enforced them.
  5. Press Preview fit, examine the comparison and use Accept. Publish each prediction with a new ID and compare it separately with observed x/y1 in Curve Viewer, adding fitted_x/fitted_y as a separate source.
Transferred 100 rpm comparison
Historical graph p0034: observations and fixed transfers, rather than chlorine recalibration. · Retained original GX-TXT/ELEC documentation image; source and hash in metadata. Atrashkevich et al. (2025), DOI 10.1016/j.watres.2025.123732 for any publication pixels. View at full resolution

This procedure retains the source relationship and makes assumptions explicit. P013 remains NOT_RUN.

Working materials

Figure 3 digitized datasets (CSV) · Model and constraint datasets (CSV)

#chlorine #Electrochemistry #GX-TXT #ODE

Other steps of this project