ELEC · Practical Guide 14 — Explore functions and sensitivity in Mathematics Explorer

by Giux Electrochemistry, GX-TXT 3 min read

Compare two conditional predictions in Mathematics Explorer and inspect the separate model used to study sensitivity to pH.

ELEC project · Practical GX-TXT guide 14 of 16.

Reproduction target: GX-TXT DEV112-P013. The original screenshots and recorded results document the historical ELEC session. A rerun on P013 has yet to be verified.

Module: Mathematics Explorer

Learning objective: Explore functions and sensitivity in Mathematics Explorer

Prerequisites / input: Saved two-function Workspace and separate pH model

Expected output: Two conditional predictions and inspection of the pH sensitivity model

Scientific background and reference results

Mathematics Explorer supports defining functions, evaluating them at selected times and publishing a comparison. First learn with two documented conditional predictions; then inspect the separate pH sensitivity model. Neither calculation creates new measurements.

Two nitrogen-free predictions at 100 rpm

Step-by-step procedure

  1. Open Mathematics Explorer in the Session copy. Historical Workspace Conditional 100 rpm nitrogen-free predictions has owner idoc_8676162010859903. Open it and save a newly named variant to follow its fields; alternatively create a separate Workspace.
  2. Set the x axis in minutes and domain 2.3743325716139645–19.843825433296708 min. Declare p_hp=5.395265515034491 [g*m^-3*min^-1], p0=6.7784383472697565 [g*m^-3*min^-1] and k_hl=0.16632963477398346 [1/min]. Descriptions retain references to native results from which the parameters were transcribed.
  3. Define two functions with output g*m^-3: p_hp*x and -p0*expm1(-k_hl*x)/k_hl. The first represents H_P with no loss, the second H_L with effective loss. For each choose explicit and enter seven times: 2.3743325716139645, 4.803864691450635, 7.3490888169938176, 9.894312942536994, 12.439537068080183, 14.869069187916853, 19.843825433296708 min.
  4. Use Plot / Refresh to inspect both branches, then Save model and Publish Graph with new identifiers. Historical Datasets have prefix hal_100rpm_no_n_conditional_prediction_01 and historical graph is p0022. These are seven theoretical query times, rather than chlorine measurements: lines connect samples without adding intermediate calculations.
Two conditional functions
Historical Workspace with the two nitrogen-free branches: parameters, domain and functions are editable. · Retained original GX-TXT/ELEC documentation image; source and hash in metadata. Atrashkevich et al. (2025), DOI 10.1016/j.watres.2025.123732 for any publication pixels. View at full resolution

Initial pH sensitivity

  1. Separately open Initial pH formation sensitivity - 25 C, owner idoc_2643434209909857 revision 7, and save a variant. The historical model contains nine native components, separate from the two functions in the preceding image. Check pH domain 6–12, 61 samples, X unit 1, k=3.07e6 [dm^3*mol^-1*s^-1], pKaC=7.537, pKaN=9.251 and initial unchlorinated nitrogen 10 [mg*dm^-3].
  2. Inspect functions and units with the retained field table. Use the saved configuration to see every definition before editing; publish any reproduced components under a new prefix. Historical prefix is ph_formation_initial25c_sensitivity_01. Dedicated editable fraction plots were incomplete.
  3. A dm^3 is exactly one litre. Converting 10 mg N/L to molarity uses nitrogen molar mass 14.0067 g/mol with consistent units, rather than the whole NH₃ molecule’s mass. Scenarios γ=1 and γ=0.78 are distinct, rather than an uncertainty band. τ_F concerns free chlorine under frozen conditions, rather than N-signal removal time. Do not extrapolate the kinetic model beyond the declared domain.

Working materials

Figure 3 digitized datasets (CSV) · Model and constraint datasets (CSV) · ELEC working files (ZIP)

#Electrochemistry #GX-TXT #Mathematics Explorer #pH

Other steps of this project