Forward Converter Design Calculator: Reset, Transformer, Inductors and Loop

reset Vin Q1 Np Df1 Dr1 L1 C1 Vout1 Df2 Dr2 L2 C2 Vout2 TL431 + opto peak current
The forward: while Q1 conducts, primary and secondaries have the same polarity (the dots), the forward diodes Df conduct and each secondary feeds its inductor, as in a buck. When Q1 opens, the freewheeling diodes Dr carry the inductor current, and the core has to be reset before the next cycle: that is the reset network’s job.

Introduction

The forward is a buck with a transformer in front: the transformer isolates and scales the voltage, and energy reaches the output while the switch conducts, not afterwards as in the flyback. That is why the transformer has no gap, the output current is continuous and the forward handles more power with less ripple. The price is reset: every cycle the flux rises for D·Ts, and if it does not return to zero before the next turn-on the core walks towards saturation. How it is brought back decides the MOSFET voltage, the maximum duty cycle and where the magnetising energy ends up.

The tool covers DC input, one to three outputs with separate or coupled inductors, diodes or synchronous rectifiers, and four reset networks. The transformer is wound on ungapped TDK N87 cores; the output inductors are designed with the engine of the inductor calculator; the loop is the peak-current one with TL431 and optocoupler from the control loop calculator. Finally a switching simulation, with leakage, reset, drain capacitance and every output, checks the numbers.

Vin Drs Np Nr Q1
Reset winding: the magnetising current returns to the input; VDS = Vin·(1 + Np/Nr), D < Np/(Np + Nr).
Vin Q1 Q2 D1 D2
Two switches: the diodes return the magnetising current to the input; each MOSFET sees only Vin, D < 50 %.
Vin Q1 Dc Rc Cc
RCD clamp: Rc sets the reset voltage; magnetising and leakage energy end up as heat.
Vin Q1 Qc Cc
Active clamp: Qc conducts while Q1 is open and Cc settles at Vin·D/(1 − D); the magnetising current reverses and the flux becomes bipolar. D can exceed 50 %.
WhatFormula
Output\( V_{out} + V_F = D\,\dfrac{N_s}{N_p}\,V_{in} \)
Reset: equal volt-seconds\( V_{in}\,D = V_r\,D_r \le V_r\,(1-D) \)
Maximum duty with reset winding\( D_{max} = \dfrac{N_p}{N_p+N_r} \)
MOSFET voltage, active clamp\( V_{DS} = \dfrac{V_{in}}{1-D} \)
Flux swing\( \Delta B = \dfrac{V_{in}\,D}{f_s\,N_p\,A_e} \)
Duty loss from leakage\( \Delta D = \dfrac{L_{lk}\,I_{L,min}\,f_s}{V_{in}}\,\dfrac{N_s}{N_p} \)

Card 1 — Specifications, reset and power stage

Outputs (the first is the regulated one)
Vout (V)Iout (A)VF diodes (V)C (µF)ESR (mΩ)
1
Reset and stage
VinL1 modeDReset limitIpkMOSFET RMS IVDSOther outputs

The design starts from the duty cycle at minimum Vin, which sets the turns ratios; at maximum Vin the duty drops in the same proportion. The limit comes from reset: with a 1:1 reset winding and with two switches the core resets only if D stays below 50 %, so 40–45 % at minimum Vin is the usual choice; with a reset winding with fewer turns than the primary you can go higher, but the MOSFET sees more. With the RCD the clamp voltage is chosen, and the tool sets it to the minimum that resets at minimum Vin times kc. With the active clamp the duty can exceed 50 % and VDS is lower, but the clamp capacitor resonates with Lm.

The output inductor ripple is largest at maximum Vin, and that is where the tool sizes them. Above a ratio of 2 the inductor runs in discontinuous conduction: the voltage of the unregulated outputs then depends on the load. Leakage is the one measured on the primary with the secondaries shorted; at turn-on the secondary current has to rise through it, and for that time the output sees zero volts: that is the duty loss, which the control recovers on output 1 but not on the others.

Card 2 — Transformer

WindingNConductorIrmsRdcFR a fsLayersLoss

The forward transformer stores no energy: primary turns come from the flux swing, which depends only on Vin·D, that is on the volt-seconds the output asks for, not on the load current. With the three passive resets the flux goes from zero to ΔB and the peak B is ΔB; with the active clamp the magnetising current reverses, the flux becomes symmetrical and the peak B is ΔB/2, so fewer turns are enough. The magnetising inductance is that of the ungapped core, AL·Np²: ferrite AL values have a 25 % tolerance, and the magnetising current and, with the RCD, the clamp power depend on Lm.

Transformer losses and temperature

Core loss follows the generalised Steinmetz equation on the real flux: it rises for D·Ts, falls during the reset time, which is shorter or longer depending on the network, and stays flat until the next turn-on; with the active clamp it falls for the whole off-time. The coefficients are N87’s at 100 °C. Copper loss is computed winding by winding with Dowell’s model on the harmonics of the real current — in the primary the reflected current plus the magnetising one, in the secondaries a trapezoid for D·Ts, in the reset winding the reset triangle — and the temperature rise with Rth ≈ 53/√Ve.

Dowell’s model here treats each winding as if it occupied the bobbin width on its own, which is the worst case; sandwiching the primary between two halves of the secondary lowers losses and leakage. The reset winding carries little current and is wound bifilar with the primary, so the leakage between the two stays small.

Card 3 — Output inductors

LCoreNGapWireRdcLossesΔTVerdict

For each output the tool picks the smallest core meeting every requirement, with the same engine and data as the inductor calculator: inductance at maximum Vin, saturation, fill and temperature. To see every candidate for one inductor, copy L, current and ripple into the inductor calculator.

With several outputs the coupled inductor is the classic choice: every winding on one core, with turns in proportion to the voltages. The outputs are tied together during freewheeling too and cross-regulation improves a lot; in exchange the currents split according to the leakage between windings, which must be kept small.

Card 4 — Loop with TL431 and optocoupler

PartPositionComputedStandard

In continuous conduction the forward is a buck: no right-half-plane zero, and with peak current control the stage has one dominant pole plus the sampling double pole at fs/2. The sense resistor sits on the primary and sees the sum of the reflected inductor currents plus the magnetising one: its Vin/Lm ramp acts as free slope compensation, and the tool adds it to the external ramp. With several separate inductors the model keeps all of them, because each one adds its share of current in the sense signal; with the coupled inductor it sees just one, with the capacitors referred.

In discontinuous inductor conduction the model is the energy one, as in the flyback: a single pole, plus the delay of the falling current. With the active clamp the average magnetising current does not return to zero every cycle but resonates between Lm and Cc, and that resonance enters the sense signal: the tool puts it in the model and keeps the suggested fc below a third of its frequency.

Card 5 — Switching check

QuantityModelSimulation

The first graph is a zoom over three periods at nominal Vin. When Q1 opens the drain rises to the reset voltage and stays there until the magnetising current returns to zero; then it rings between Lm and Cd and settles around Vin, where the secondary diodes hold it. With the active clamp the drain stays at Vin + Vc for the whole off-time and the magnetising current reverses.

The table compares the calculation with the simulation: the peak VDS, the magnetising current, the RCD clamp power, the output voltages — the unregulated ones shift because of the duty loss, which is not the same for all of them — and the loop gain at fc, measured by injecting a signal as with a network analyser. The second graph is a load step on the main output; each point is the average over one period.

In the simulation the MOSFETs are switches, diodes have a fixed drop, synchronous rectifiers are driven by the controller with no dead time, and the given leakage sits entirely on the secondaries, in parallel with each other: primary and reset winding are bifilar with no leakage between them, so the drain spike at turn-off is missing. The coupled inductor has 1 % leakage between windings: the current splits between outputs according to it, and the comparison with the model, which treats them as a single output, depends on it. With the active clamp, dead time and zero-voltage switching are not simulated. Ringing between leakage and Cd does not decay, because the simulation has no losses at tens of MHz.