Phase-Shifted Full Bridge Design Calculator: ZVS, Magnetics, Loop
Introduction
The phase-shifted full bridge is the isolated converter for a few hundred watts to a few kilowatts, after a PFC, when the output is low voltage and high current. The four MOSFETs switch at zero voltage without a proper resonant network: the energy to charge and discharge the Coss comes from the reflected load current and the series inductance. Regulation is at fixed frequency, as in a forward, and the duty cycle shows up as a phase shift between the two legs. Unlike the LLC the input voltage and load range is covered without moving the frequency; in exchange ZVS is lost at light load, and part of the period goes into reversing the primary current.
The tool follows the design of TI’s application note on the UCC28950 (SLUA560) and Andreycak’s note on zero-voltage switching (SLUA107): turns ratio, output inductor, series inductance, dead times, magnetising inductance. It covers the centre-tapped rectifier, the current doubler and the bridge, with diodes or synchronous rectifiers. Then a cycle-by-cycle simulation of the circuit, with the Coss, the leakage, the clamp diodes, the rectifier capacitance with its snubber and peak current-mode control, checks what the formulas do not see: where each leg loses ZVS, the duty loss, the voltage on the rectifiers. The transformer and the inductors are wound on the cores of the inductor calculator; the loop is designed on Ridley’s model and the TL431 with the method of the control loop calculator.
| What | Formula |
|---|---|
| Turns ratio | \( n = \dfrac{N_p}{N_s} = \dfrac{V_{in,min}\,D_{max}}{k\,(V_{out}+V_F)},\quad k = 1\ \text{centre tap, bridge},\ k = 2\ \text{current doubler} \) |
| Effective duty cycle | \( D_{eff} = \dfrac{k\,n\,(V_{out}+V_F)}{V_{in}} \) |
| Output inductor | \( L_o = \dfrac{V_{out}\,(1-D_{eff})}{\Delta I_L\cdot 2f_s} \) |
| Duty loss | \( \Delta D = \dfrac{2\,L_t\,(I_a+I_b)}{V_{in}\,T_s},\quad I_{a,b} = \dfrac{k_I\,(I_{out}-\Delta I_L/2)}{n} \pm I_{m,pk},\quad L_t = L_r+L_{lk} \) |
| Lagging-leg ZVS | \( \tfrac{1}{2}\,L_t\,I_{lag}^2 \ge \tfrac{1}{2}\,C_r\,V_{in}^2,\quad C_r = 2\,C_{oss}+C_{tr},\quad t_{lag} = \dfrac{\pi}{2}\sqrt{L_t\,C_r} \) |
| Leading-leg ZVS | \( t_{lead} \ge \dfrac{C_r\,V_{in}}{I_{lead}},\quad I_{lead} = \dfrac{k_I\,(I_{out}+\Delta I_L/2)}{n}+I_{m,pk} \) |
| Peak current mode (Ridley) | \( m_c = 1+\dfrac{S_e+R_i V_{in}/L_m}{S_n},\quad Q_p = \dfrac{1}{\pi\,(m_c D’-0.5)} \) |
Card 1 — Specifications, turns ratio and duty cycle
| Vin | Deff | ΔD | reversal t | Dcmd | ΔIL | |
|---|---|---|---|---|---|---|
The secondary sees Vin/n only while the two legs are on opposite rails; for the rest of the half period the two high MOSFETs, or the two low ones, are on together, the primary is shorted and the current freewheels. The rectifier and output filter are those of a buck switching at 2·fs, with duty cycle Deff. The turns ratio is chosen so that Dmax is enough at minimum Vin: SLUA560 uses 70 %, to leave room for the duty loss and for transients. In the current doubler the secondary sees Vin/n in both half periods but each inductor carries half the current, and the turns ratio halves.
The duty loss is the price of ZVS. When the lagging leg changes rail, the primary current must go from −Ia to +Ib through Lt, with slope Vin/Lt; until it is done, all rectifiers conduct and the secondary stays shorted. The command Dcmd must then exceed Deff by ΔD, and ΔD grows with load and with Lr. The ΔD formula here is derived from that slope; the check in card 5 compares it with the simulation.
Card 2 — Zero-voltage switching
| Load | EL/EC | tdead/tcharge | Residual, lagging | Residual, leading |
|---|
The two legs do not switch the same way. The leading leg opens at the end of the power transfer, when the primary carries all the reflected load current, held up by the output inductor: the node moves fast and a short dead time is enough. The lagging leg opens during freewheeling, when the secondary is shorted: only the energy in Lt is left to move the node, and it must be enough to charge and discharge Cr up to Vin. Andreycak says it plainly: this is the hard leg. Its dead time is a quarter of the resonant period of Lt and Cr. The tool computes the leading-leg dead time as a constant-current charge of Cr, with the valley reflected current at load x and a 20 % margin: it stays conservative, because in that transition the node also moves capacitances the formula does not count.
With computed Lr, the tool picks the inductance that gives lagging-leg ZVS at maximum Vin from load x upward. The energy balance is that of SLUA560 equation 40; the current, though, is the one actually flowing when the leg opens, at the end of freewheeling and at load x, with the ripple valley plus the magnetising current. More Lr means ZVS from a lower load, but also more duty loss and a longer dead time. Coss is the energy-equivalent one, which some datasheets give as Co(er); the transformer capacitance adds to it. The “minimum, control” Lm is SLUA560’s equation 8: the magnetising current ramp stays below half the one reflected from the output inductor, so peak current-mode control sees the load and not the transformer.
The graph comes from the simulation at maximum Vin, nine loads: the voltage left across the MOSFET when it turns on, as a percentage of Vin. Below, the formula ratios: ZVS is there when they exceed 1.
Clamp diodes, and why ZVS comes earlier than the formula
When the transfer starts, the leakage and the rectifier capacitance ring, and the rectifier voltage climbs well above Vin/n. With Lr separate from the transformer, the two diodes on node X between Lr and the primary cut the ringing: as soon as X tries to leave 0…Vin, a diode conducts and the primary voltage stays put. The excess energy goes back to the input instead of into a snubber. The result shows in the card 5 table, on the reverse-voltage row.
There is one more effect, which the energy formula does not contain. While a clamp diode conducts, Lr sees almost no voltage, and its current stays at the value it had when the diode turned on, higher than the reflected load current. When the lagging-leg dead time comes, Lt carries more current than the formula assumes, and ZVS arrives at lower loads. The simulation shows it; the formula remains the conservative figure.
Card 3 — Transformer, series inductance and output inductor
| Winding | N | Conductor | Irms | Rdc | FR a fs | Loss |
|---|
The transformer flux is a trapezoid: it rises for Deff·Ts/2 while the secondary conducts, stays flat during freewheeling, falls in the opposite half period. The swing comes from the volt-seconds of the simulation at minimum Vin and full load, and core losses from the iGSE on N87 with that waveform. With a 12 V output the secondary has few turns, and the minimum integer decides everything else: the primary follows from the turns ratio, and peak B often stays below the limit. The gap is only there to bring Lm to the card 2 value.
Copper losses are computed with Dowell’s model on the harmonics of the simulated currents. With the primary split into two halves around the secondary, each portion sees half the magnetomotive force and the equivalent layers halve: it is the normal arrangement in a full bridge, and here it matters a lot. The fill counts the cross-section of insulated wires, or for foil the whole layer with 0.05 mm of insulation; each winding gets a share of the fill in proportion to the copper it needs. With a centre tap each half of the secondary conducts for half a period, plus freewheeling, where it carries about half the current.
The series inductance carries the primary current, with no DC, and its B follows the current: the peak comes from the simulation. The output inductor is designed as in the inductor tool, with the output current, the ripple at maximum Vin, where it is largest, and frequency 2·fs; in the current doubler each inductor carries half the current at fs.
The leakage Llk used in card 2 is not computed: it depends on how the transformer is wound, and must be measured on the first sample with the secondary shorted. The ETD 44 and ETD 49 cores come from TDK datasheets; the others are those of the inductor tool.
Card 4 — Peak current-mode loop
| Part | Position | Computed | Standard |
|---|
| f | |G| model | |G| simulation | ∠G model | ∠G simulation |
|---|
In peak current mode the leading leg opens when the primary current, read by a current transformer, reaches the level the voltage loop asks for. Seen from the output, the full bridge is a buck switching at 2·fs, with input voltage Vin/(k·n) and inductance Lo/k; the sensor sees the inductor current referred to the primary, plus the magnetising current. On this equivalent buck the tool uses Ridley’s model: one pole set by the load and Co, the ESR zero, and a pole pair at half the sampling frequency.
The magnetising ramp already acts as compensation: Ri·Vin/Lm adds to the external ramp. With the high Deff of a full bridge compensation is still needed, otherwise the half-frequency poles become poorly damped. If you leave Se empty, the tool picks it so that at minimum Vin, where D′ is smallest, Qp equals 1. The TL431 with the optocoupler is sized with the K factor, as in the loop tool.
The physical check of the model: the stage is also measured on the simulation, by modulating the current level at three frequencies and reading the output response; then the loop is closed with the TL431 and the loop gain at fc is measured by injecting a signal, as on the bench.
Card 5 — Switching check
| Quantity | Calculation | Simulation |
|---|
| Losses | P |
|---|
* From card 3, at minimum Vin and full load.
The first graph is a zoom over two periods. The voltage between the legs shows the ±Vin stretches, the freewheeling at zero and the dead-time ramps; the primary current does not go to zero during freewheeling, because it carries the reflected output current, and it reverses with the slope of Lt at the start of each transfer. The rectified voltage starts with the delay of the duty loss, and the spike at the start of the transfer is what the clamp diodes and the snubber have to contain.
The simulated Deff is somewhat higher than the formula’s. During the transfer the output inductor current rises, and the primary current with it: Lt, referred to the secondary as Lt/n², forms a divider with Lo, and the rectified voltage stays a few percent below Vin/n. To get the same Vout the control lengthens the transfer. With a large Lr the effect is visible; the formula, like SLUA560’s, does not contain it.
The table compares the formulas with the simulation at the chosen point. The losses combine MOSFET conduction, the energy lost if a leg switches hard, the clamp diodes, the snubber, the rectifiers and the card 3 magnetics. The load step runs in closed loop with the TL431 from card 4.
In the simulation the MOSFETs are switches with RDS(on) and constant Coss on the node; synchronous rectifiers are diodes with their resistance, diodes have a fixed drop and return Qrr by conducting backwards; the transformer is Lm plus leakage, with the rectifier capacitance referred to the primary. Gate drive, synchronous-rectifier switching losses, start-up and no-load operation are not simulated. Sources: TI, Phase-Shifted Full Bridge DC/DC Power Converter Design Guide (SLUA560); L. H. Andreycak, Designing a Phase Shifted Zero Voltage Transition Power Converter (SLUA107); R. B. Ridley, A New, Continuous-Time Model for Current-Mode Control, IEEE Transactions on Power Electronics, 1991; P. L. Dowell, Effects of eddy currents in transformer windings, Proceedings of the IEE, 1966.