Parameters & Statistics: read estimates and uncertainties
A regression provides numerical coefficients, but the scientific significance of the result depends on their units, standard errors, assumptions about experimental errors and the statistical relationship between parameters.
Reference interface: GX-TXT DEV112-P011 · Dataset Curve Fit.
From the curve to the estimated coefficients
We consider eleven synthetic observations of a voltage U as a function of time t. Open the c17_linear_calibration dataset, select X = Time (s) and Y = Voltage (V), then load the curve with Add Dataset curve.
In the model panel set Y=f(X), Model = linear, Fit points = all and Output domain = source. Press Preview fit and select the Parameters & Statistics tab.
In the range examined, the function obtained is:
U(t) = a + b · t, with a ≈ 0.250000 and b ≈ 0.150000 V/s.
The table identifies the intercept as intercept and the slope as slope. These names should not be confused with the order in which another model may require initial values: the meaning of the coefficients is always defined by the expression of the current model.
Interpret the columns of the table
The table has the Parameter , Estimate, Unit, Standard error, Confidence interval and Role. These are six distinct aspects of the result.
Estimate is the numerical value of the coefficient obtained from the fit; Unit specifies the physical dimension; Standard error quantifies the uncertainty of the estimate within a statistical model; Confidence interval reports an inferential range at a stated level; Role indicates whether the parameter was estimated freely or held fixed.
The slope is in V/s because it describes a change in voltage per unit time. The intercept is in V, since it is the predicted voltage at t = 0 s. It is not correct to give both the same unit.
The free role indicates that each coefficient was determined from the data. For a fixed parameter, by contrast, it is not appropriate to report a standard error as if it had been freely estimated by the regression.
What the standard error tells you
In our example, the standard error of the intercept is about 0.009017 V, while the slope error is about 0.001524 V/s. These values do not represent the scatter of the individual points around the curve: they represent the statistical variability expected for the respective estimates under the model assumptions.
For an ordinary two-parameter linear regression, an estimate of the error variance is:
s² = Σ rᵢ² / (n − 2),
where rᵢ are the residuals and n is the number of observations. The standard errors of the coefficients depend on both this variance and the distribution of the X values. For example, concentrating the observations in a narrow range can increase the uncertainty of the slope.
In the eleven-point series, the value RMSE = 0.014460 V describes the root-mean-square scatter of the residuals. It should not be confused with the standard error of a single estimate, nor with the uncertainty of a future observation.
State the statistical assumptions for intervals
The default configuration of Curve Fitter uses the Unspecified — no interval claim assumption. In this condition the Viewer can show numerical estimates and covariance information, but does not automatically assign a confidence interval to the coefficients.
To declare the error model, open Fit → Measurements and uncertainty → Statistical assumptions and intervals….
For the linear example, choose Measurement error assumption = Independent Gaussian — estimated variance, set Confidence level = 0.95 and leave Training measurement role = No measurement weighting and Response interval = No response interval.
Press Apply, close the settings window and run Preview fit again. The program recalculates the result, now also using the declared statistical assumptions.
The Gaussian choice must be consistent with what is known about the experimental errors: selecting it in the menu does not by itself show that the real data satisfy the assumptions of independence, common variance and normal distribution.
Read a 95 % confidence interval
For the eleven observations, the linear model estimates two coefficients and leaves 9 residual degrees of freedom, n − 2. Assuming independent Gaussian errors with variance estimated from the residuals, marginal intervals for the coefficients can be obtained from Student’s t distribution:
CI = estimate ± t 0.975;9 × standard error.
| Parameter | Estimate | Standard error | Confidence interval 95 % |
|---|---|---|---|
| intercept (V) | 0.250000 | 0.009017 | 0.229601 – 0.270399 V |
| slope (V/s) | 0.150000 | 0.001524 | 0.146552 – 0.153448 V/s |
The correct frequentist interpretation is not that the fixed parameter has a 95 % probability of lying in this particular interval. Rather, the construction method, repeated on samples obtained under the same conditions and under the stated assumptions, would produce intervals containing the true value in the nominal proportion of cases.
These are marginal intervals for individual coefficients, not a simultaneous region guaranteeing joint coverage of intercept and slope.
Inspect a parameter and its units
Select the slope row in the table. Below the list a description appears with its unit, the standard error, the confidence limits and, where applicable, the reason why a result is unavailable.
The number of decimal places shown does not reflect the actual precision of the estimate. When reporting a result, round it consistently with its uncertainty and state the confidence level if you quote an interval.
Understand the correlation between coefficients
The parameters of the same regression are not necessarily estimated independently. For a straight line, if the slope increases the intercept can decrease to keep the curve close to the observed points. This compensation is reflected in the covariance matrix.
From the Results → Measurement and uncertainty results → Parameter correlation… menu you can read the correlation matrix of the free coefficients.
The matrix is symmetric, with diagonal elements equal to 1. The negative correlation in this example also depends on where the time origin is placed: centering the time coordinate on its mean can change the correlation between the new intercept and the slope without changing the predictions of the line.
When parameters are strongly correlated, marginal intervals may not adequately describe the joint uncertainty region. For simultaneous comparisons, or to propagate uncertainty to a derived quantity, the full covariance must be taken into account.
What changes at 90 %
Statistical assumptions and intervals… : reopen this window and set the confidence level to 0.90, keeping the Independent Gaussian — estimated variance assumption unchanged.
Confirm with Apply, close the window and request a new Preview. The intercept and slope estimates and their standard errors stay the same, because the fit and the data have not changed. The intervals, on the other hand, become narrower.
| Parameter | CI 90 % | CI 95 % |
|---|---|---|
| intercept (V) | 0.233470 – 0.266530 V | 0.229601 – 0.270399 V |
| slope (V/s) | 0.147206 – 0.152794 V/s | 0.146552 – 0.153448 V/s |
A narrower interval does not mean that the model has become more accurate: a different confidence level was requested. For a correct comparison between results, always state the level used.
Do not confuse parameter uncertainty with predictive capability
The uncertainty of the intercept or slope is not the same as the prediction uncertainty of a voltage measured in the future. Confidence interval for a coefficient, Confidence interval for average response and Prediction interval for a future observation answer different questions.
For the latter, the variability of the new observation counts in addition to the uncertainty of the coefficients. The statistical settings tab therefore distinguishes the types of response interval and lets you declare any known experimental uncertainties.
Likewise, the availability of a standard error does not by itself guarantee that the uncertainty is realistic for the phenomenon: errors correlated in time, heteroscedasticity, a wrong mathematical model or non-independent observations can invalidate the assumptions of ordinary inference.
For this reason, before presenting an interval as a scientific result, check the quality of the fit, the distribution of the residuals and the plausibility of the error model. The Residuals and Parameters & Statistics tabs complement each other.