Dual Active Bridge Design Calculator: Power, ZVS, Loop

V1 Q1 Q2 Q3 Q4 A B L n : 1 Q5 Q6 Q7 Q8 C D C2 Rbat Vbat V2
The dual active bridge. Both bridges run at 50 % and put a square wave across the transformer; the phase shift φ between the two waves sets how much power flows through L, and its sign sets the direction. L includes the transformer leakage. The magnetising inductance Lm is across the primary and is not drawn.

Introduction

The dual active bridge is the bidirectional isolated converter: two full bridges, one per side, tied by a transformer and an inductance. It sits between the DC bus of a PFC or an inverter and a battery, in electric-vehicle chargers and storage systems. Unlike the phase-shifted full bridge the secondary is also made of driven MOSFETs, and current can flow both ways without changing the circuit. With single phase shift (SPS) modulation each bridge makes a 50 % square wave, and the only control is the phase shift between the two.

The starting example is Texas Instruments’ reference design TIDA-010054 (TIDUES0): 700 to 800 V bus, 350 to 500 V battery in SPS, 10 kW at 100 kHz, Wolfspeed SiC MOSFETs, turns ratio 1.6 and 35 µH in series. The tool computes power, currents and zero-voltage switching with the SPS formulas, checks them with a switching simulation of the two bridges with dead times and Coss, winds the transformer and the inductance on the cores of the inductor calculator and designs the loop on the battery current with the method of the control loop calculator.

WhatFormula
Power\( P = \dfrac{n\,V_1 V_2\,\varphi\,(\pi-|\varphi|)}{2\pi^2 f_s L},\qquad P_{max} = \dfrac{n\,V_1 V_2}{8 f_s L}\ \ (\varphi = \pi/2) \)
Voltage gain\( d = \dfrac{n\,V_2}{V_1},\qquad I_{base} = \dfrac{V_1}{\omega L} \)
Currents at the edges\( I_a = \left[d\,|\varphi|+(1-d)\tfrac{\pi}{2}\right] I_{base},\qquad I_b = \left[|\varphi|-(1-d)\tfrac{\pi}{2}\right] I_{base} \)
RMS current\( I_{rms} = \sqrt{\tfrac{1}{3}\left[I_a^2+I_b^2+\left(1-\tfrac{2|\varphi|}{\pi}\right) I_a I_b\right]} \)
ZVS, sign\( \varphi > \left(1-\tfrac{1}{d}\right)\tfrac{\pi}{2}\ \ \text{primary},\qquad \varphi > (1-d)\,\tfrac{\pi}{2}\ \ \text{secondary} \)
ZVS, dead time\( \dfrac{2\,C_{o(tr)}V}{I} \le t_d \le \dfrac{2\,C_{o(tr)}V}{I}+\dfrac{I}{|di/dt|} \)
Battery current\( \dfrac{\partial I_o}{\partial\varphi} = \dfrac{n\,V_1\,(\pi-2|\varphi|)}{2\pi^2 f_s L},\qquad \dfrac{i_{bat}}{\varphi}(s) = \dfrac{\partial I_o}{\partial\varphi}\,\dfrac{1+sC_2R_{esr}}{1+sC_2(R_{esr}+R_{bat})}\,e^{-1{,}5\,sT_s} \)

Card 1 — Power, currents and ZVS range

Transformer and inductance
MOSFETs, output and battery
V1V2dPφI at the edge: pri · secIrms: pri · secZVS priZVS sec

The inductance L, which includes the leakage, is the link: it sees the difference between the two square waves, and the current through it carries the power. Power grows with the phase shift up to 90°; beyond that it no longer grows and only the current circulating without doing work increases. So L is chosen so that rated power passes at the worst corner, minimum V1 and V2, with a reasonable phase shift. TI picks 35 µH, which at 800 V and 500 V lets up to 22.9 kW through and gives 10 kW at about 23°.

Zero-voltage switching depends on the gain d = n·V2/V1. With d = 1 the two waves have the same amplitude and both bridges switch at zero voltage down to low loads. With d < 1, a discharged battery, the current at the secondary edge changes sign at partial load and the secondary switches hard; with d > 1 the primary does. The map colours the regions from the formulas; the squares come from the simulation, twelve points at three voltages and four loads.

The dead time: too short or too long

The current sign is not enough. In the dead time the current at the edge must carry the leg node from one rail to the other, that is charge and discharge the two Coss: with Co(tr), the charge-equivalent one, the time needed is 2·Co(tr)·V/I. But right after the edge the voltage across L changes, and the current starts to fall: if it reverses before the MOSFET turns on, the body diode turns off and the node swings back, and switching becomes hard precisely because the dead time is too long. The tool checks both conditions; the table gives the cause as “sign”, “charge” or “reversal”.

This second limit depends on the power direction: after one bridge’s edge, the current falls fast if the other bridge has not yet switched and the two voltages add across L. That is why with the battery at 350 V the secondary loses ZVS at full load when power flows from the battery to the bus, and keeps it the other way. At very light load, with phase shifts of a few degrees, the dead time itself weighs as much as the phase shift and the ideal formulas are no longer enough: there the simulation is what counts.

The starting MOSFETs are those of TIDA-010054. For the primary C3M0075120K the Wolfspeed datasheet (C3M0075120K) gives Co(tr) = 96 pF and Co(er) = 67 pF from 0 to 800 V and typical RDS(on) 100 mΩ at 150 °C. For the secondary C3M0030090K (C3M0030090K) Co(tr) and Co(er) are not given: the tool uses Coss = 144 pF at 600 V, which underestimates the charge at low voltage and makes the secondary ZVS somewhat optimistic; typical RDS(on) 41 mΩ at 150 °C. VSD = 4 V is the typical value at 150 °C in both datasheets.

Card 2 — Transformer and series inductance

WindingNConductorIrmsRdcFR a fsLoss

The primary sees a ±V1 square wave at fs, so peak B is V1/(4·Np·Ae·fs) and does not depend on load: turns are set at maximum V1. Ns is the first integer that, with the turns ratio, gives enough primary turns. The gap brings the magnetising inductance to the card 1 value: TIDA-010054 uses 720 µH. Currents come from the simulation at the worst point, maximum V1 and minimum battery at maximum power or current, and copper losses from Dowell’s model on their harmonics, with the same fill criterion as the phase-shift tool.

At 10 kW and 100 kHz a transformer wound on an E core dissipates tens of watts, and in natural convection it runs too hot: the tool shows the thermal resistance needed to stay within the limit, next to the still-air estimate. With forced air or a cold plate, enter the real Rth. TIDA-010054 uses a planar transformer with integrated inductance, 50 W of transformer loss and 15 W in the inductance according to TI’s design.

The ETD 59/31/22, E 65/32/27 and E 70/33/32 cores come from the October 2024 TDK datasheets; for the E cores, window and mean turn length are those of the single-set coil former. The usable bobbin width is not in the datasheet text and is estimated as in the inductor tool. The leakage included in L must be measured on the first sample.

Card 3 — Battery current loop

f|G| model|G| simulation∠G model∠G simulation

A DAB charging a battery is controlled in current: the reference comes from the battery management system, and the voltage is a slow outer loop. In the SPS averaged model the output current Io depends only on φ and V1, not on V2: the secondary bridge behaves as a current source. The battery current is the part of Io that does not go into C2, with a pole set by C2 and the battery internal resistance. The tool uses the nominal point, nominal V1 and V2 at full load.

Control is digital, as in TIDA-010054: once per period the battery current averaged over the last period is read, the new φ is computed and applied from the next period. That is one period of computation delay, half a period of hold and half a period of averaging: at 100 kHz they add up to 20 µs, which at 5 kHz cost 36° of phase, and they are what limits fc. The compensator is a PI with a pole, sized with the K factor; the tool gives Kp, Ki and the pole to put in the firmware, with φ in degrees.

Physical check of the model: the plant is measured on the simulation by modulating φ at three frequencies; then the loop is closed with the same compensator, run once per period as in firmware, and the loop gain at fc is measured by injecting a signal on the current measurement. In the simulation a change of φ is applied by half at the first edge of the period, as Krismer and Kolar suggest, because otherwise the magnetising current and the current in L pick up a DC component.

Card 4 — Switching check

Turn-off losses, from the datasheet
QuantityFormulaSimulation
LossesP

* From card 2, at the worst point for currents.

The first graph shows two periods at the chosen point. The two voltages are square waves shifted by φ; the current in L rises steeply while the two waves have opposite signs and is almost flat when they have the same sign, if d is close to 1. At the edges you read the currents that decide ZVS, and in the dead times the node ramps. In reverse the same waveforms run backwards.

The table compares the formulas with the simulation. The losses combine conduction of the two bridges, the body diodes in the dead times, the energy lost if a leg switches hard, an estimate of turn-off losses and the magnetics. Turn-off cannot be seen in a simulation with ideal switches: the tool scales the datasheet Eoff with the current and voltage at the edge, as TI does with the full value. It is an upper estimate, because the datasheet measures it with hard switching, while with ZVS the Coss acts as a snubber. The step is on the current reference, in closed loop.

In the simulation the MOSFETs are switches with RDS(on) and a constant Coss per node, body diodes have a fixed drop, the V1 bus is stiff and the battery is a voltage with its internal resistance. Gate drive, body-diode recovery, transformer capacitance and start-up are not simulated. Sources: TI, Bidirectional, Dual Active Bridge Reference Design for Level 3 Electric Vehicle Charging Stations (TIDUES0); M. N. Kheraluwala, R. W. Gascoigne, D. M. Divan, E. D. Baumann, Performance characterization of a high-power dual active bridge dc-to-dc converter, IEEE Transactions on Industry Applications, 1992; F. Krismer, J. W. Kolar, Accurate small-signal model for the digital control of an automotive bidirectional dual active bridge, IEEE Transactions on Power Electronics, 2009; Wolfspeed datasheets C3M0075120K and C3M0030090K; P. L. Dowell, Effects of eddy currents in transformer windings, Proceedings of the IEE, 1966.