Read and adjust contours
Adjust the contour floor, level count, and sign. Navigate the map and select a sample to read its coordinates.
Read the axes and marginal profiles
In the F1/F2 plane, F1 is vertical and F2 is horizontal. Both axes show chemical shift in ppm. Their ranges and ordering come from the NMRPipe header. On the supplied data, the chemical-shift scales run in decreasing order. The dashed orange lines cross at the selected sample. The blue profile above the map is the row along X at the selected Y coordinate. The blue profile on the right is the column at the selected X coordinate. The gray trace shows the maximum along the other axis of the displayed plane.
In Slice coordinates, move the axis slider and release it. The ppm value corresponds to the nearest sample. Clicking the map sets the coordinates on both displayed axes. Selected shows the sample and its Intensity, which can be positive or negative. To inspect a maximum listed in the table, use its coordinates to locate it on the map and click it.

Adjust Contour floor and Levels
Contour floor (fraction of max) starts at 0.08. Levels starts at 8. The floor sets the minimum contour level. The calculation uses a fraction of the absolute maximum of the plane, with a minimum scale of 1. The level count determines how many geometrically spaced levels are proposed between the floor and the maximum. A contour appears only where the matrix reaches its level.
Use the field arrows or type a value. The arrows allow 0.005–0.9 for the floor and 2–20 for the levels. After setting the values, click Apply contours. Lower values reveal weak detail and may also show background structure. Higher values retain mainly the strongest peaks. For HSQC, the table goes from 25 rows at 0.005 to 1 at 0.9.
If NMR worker returned malformed output appears after Apply contours, check the case of a slice with no positive maxima above the floor before treating the map as updated.


Show positive or negative contours
Positive and Negative are both enabled when the viewer first opens. Positive shows blue contours and Negative shows red contours. Each click redraws the plane. When both checkboxes are off, the background and profiles remain. The sign of the intensity depends on the experiment and phase. Check the phase and provenance before assigning chemical meaning to a negative signal.
Cross-peaks above contour floor lists up to 25 positive local maxima above the floor, ordered by intensity. Its columns are X ppm, Y ppm, and Intensity. Toggling blue or red contours does not change the table’s selection criterion. The table may include diagonal maxima or background features. For a targeted check, identify the point by its coordinate on each axis.

Zoom, pan, and return to the full plane
Place the pointer inside the plot. Scroll up to zoom in around the pointer and down to zoom out. Right-drag to pan the visible range. Reset view restores the full range on both axes and retains the point indicated by the cursors. Left-click to select a sample. These actions change the display and selected coordinates. The recorded samples remain in the matrix.