Five exercises with real spectra
1. Open the first entry and identify a processed spectrum
Select guida-cambridge-nmr and click Open library. Check main_3_3a_0_0, nucleus ^1H, and the frequency of about 400.33 MHz. The sample is YP80F dosed with 8.8 psi of ¹³CO₂. Look for already_processed in the provenance. The 131,072-sample trace spans about 24.94 to −25.02 ppm. The dominant signal in the data is near 2.29 ppm. The plot scale provides an approximate reading.

2. Open a specific entry and check the FID processing
In the same library, open main_3_3a_0_22 with Entries → Open entry. This is a second ¹H measurement at about 400.33 MHz, using deionized water and sample 307. The 8,192-sample trace comes from the FID. Scroll through the provenance to fid_fft, then check the parameters and the change in Reference. The largest absolute value in the derived real component is near 0.62 ppm. Sample shows the change in sample.

3. Compare two nuclei in the same sample
From the second entry, open main_4_4a_0_22 with Open entry. Compare Sample, which still identifies sample 307 and its preparation, with Nucleus and Frequency. The nucleus is now ^13C, and the frequency is about 100.67 MHz. The range extends from about 358.27 to −138.33 ppm. The largest absolute value of the derived trace is near 119.76 ppm. The difference in range and frequency is visible even at the same window width.

4. Identify the solvent and sample preparation in a titration
In Entries, open si_s8_8b_4_82_x_10_3. Check the reported sample 20uL 0.5M HCl, solvent CD3CN, and ¹³C frequency of about 150.90 MHz. The original is in the SI/S8 supplementary data folder. The trace has 32,768 samples, with the largest absolute value near 160.14 ppm. Check Solvent against the reference for sample 307 before comparing peak positions.

5. Find the DSS reference in a different repository
Prepare and install guida-bmrb-etanolo as described in the chapter on data sources. Select bmse000297-1h and click Open entry. Verify Nucleus ^1H, the frequency of about 400.13 MHz, solvent D₂O, and Shift reference DSS. Look for the ethanol groups near 1.17 and 3.64 ppm. The trace contains 32,768 samples. The signal with the largest absolute intensity is near 4.81 ppm. Identifying ethanol groups requires more than finding the strongest signal in the trace.
Select and copy the text in the provenance pane. Check the BMRB archive and the Bruker 1r path. All five examples were opened again in an isolated profile without an active session. Browse the reference library to inspect spectra. Acquiring a numerical Dataset is a separate procedure.