Select the source, overlay, and plot
Select the spectrum and check the metadata
In NMR source, choose the Dataset. Check Nucleus, Frequency [MHz], Solvent, and Reference below the selection. They show the observed nucleus, frequency, solvent, and chemical shift reference metadata. Compare them before overlaying two traces. Source type gives the original file’s domain, Processing describes how the trace was prepared, and Source SHA-256 gives the hash of the original. Acquiring the same JCAMP file with different settings can produce distinct Datasets with the same source hash.

Overlay two compatible traces
In Compatible overlay, leave the selection blank to show only the primary spectrum. To overlay another spectrum, choose its ID. The list shows other Datasets for the same nucleus. Switching the primary to ¹³C removes an incompatible ¹H overlay. The list filters by nucleus. Check frequency, provenance, chemical shift reference, phase, range, and intensity scale separately.
Before comparing two processing runs on the same FID, you can run the same analysis over the same ranges. The relative scale of the processed traces depends on each Dataset’s normalization. Any Detected peaks markers belong to the primary spectrum.
Choose the ppm axis direction
In ppm direction, reverse puts higher values on the left, following the NMR convention. normal shows increasing values to the right. Changing direction affects the figure while preserving the ppm coordinates and numerical results. Create a new variant with Open persistent NMR graph to see the change.
Create and reopen the persistent plot variant
- Choose the source, overlay, and direction. Click Open persistent NMR graph. GX-TXT creates a
plot.dataset.xy/pNNNNvariant and opens PlotSpec v2 Series. The title shows the variant number. - In the editor, check the series using Dataset, X, Y, Kind, and Label. A single trace shows
spectral_x,spectral_y, andline. After analysis,scattermay appear for peaks in the primary spectrum. Traces can point to.nmr.displayif the analysis published it. The plot uses that display series. The integral was calculated on the analysis Dataset. - To view the figure, open Plots in the main window. Use Refresh if needed, select Plot pNNNN, and open Graph → Open PNG 1:1. In the image window, use Fit to fit both axes. Zoom + and Zoom – change the zoom. Reset returns to 1:1. Drag with the left mouse button to draw a rectangle, then use Fit area to fit the selection. Without a rectangle, the viewer displays Select an area first. Show annotations toggles any annotations on the figure. The variant belongs to the session and remains accessible after closing the NMR viewer. Reopening the viewer from its tile in the same session restores the source, overlay, and direction used for the plot.

Reopen the viewer after switching sessions
Reopen Viewers → NMR Spectrum after each session switch. In the tested version, a viewer left open can continue to show sources and overlays from the previous session. Trying to plot in an empty session gives Dataset … is not an acquired NMR spectrum. Reopening the viewer from its tile shows the correct state and disables the plot button. In a session with spectra, check the ID and metadata in the new window before plotting.
