From RCA’s 1957 plots to two questions about grid control

In the Zenith Flash-Matic receiver, two small 2D21 thyratrons drove the solenoids for the latching power and sound controls. The schematic shows the 6BX7-GT doing a different job: it drives the tuning motor relays. I wanted to understand what happens between a grid pulse and the discharge inside the thyratron. How long does the pulse have to last to fire the tube? Once the anode current has stopped, how soon can the same grid prevent it from firing again? The Flash-Matic receiver and its schematic.

I traced both stages through the experiments J. A. Olmstead and M. Roth published in 1957. The RCA test circuits let them vary voltage, pulse duration and peak current under defined conditions. In the television receiver, drive impedance and the inductive load also matter. The 5 and 12 A figures below are peak currents from the RCA tests. The Zenith coil current and actuation times still need to be established. Olmstead and Roth, RCA Review, June 1957, pp. 272–284.

A pulse to fire the tube, a probe to test for refiring

In Figure 1, the anode supply feeds a 60 Hz chopper and reaches the anode through 8 kΩ. The same chopper synchronizes the grid pulse generator. A delay places the positive rectangular G1 pulse in the high half-cycle of the anode waveform, starting from a negative grid bias. The oscilloscope monitors G1 at the pin and the loaded anode voltage, both with respect to cathode K. The G2 screen grid connects to its own supply through 1 kΩ. Olmstead and Roth, RCA Review, 1957, Figures 1–2, p. 274.

In Figure 2, I follow the leading edge of the G1 pulse, its dashed tail, and finally the fall in anode voltage. At first, the pulse promotes ionization. Once the ions screen the G1 field sufficiently, cutting the pulse short can no longer prevent the discharge from starting. The authors detect conduction from the voltage drop at the loaded anode. The leading edge, loss of grid control, onset of conduction and its appearance on the anode trace are distinct events. The dashed tail can be omitted. The critical pulse width can therefore be slightly shorter than the ionization time Ti as RCA defines it. The authors considered this difference negligible for the 2D21 under their test conditions. Figure 2, p. 274.

The recovery test uses a different circuit. In Figure 6, an oscillator drives the first grid pulse and the main anode pulse. The discharge lasts long enough to establish the test conditions. A second, delayed anode circuit then reapplies a positive voltage as a probe. The interval from the end of the main anode current to the leading edge of the probe is Tr. With the previous peak current, delay and probe voltage fixed, the experimenters adjust G1 until the probe just fails to refire the tube. G2 returns to ground through 1 kΩ. The grid can already prevent refiring while it is still collecting ions. I followed both measurements to see how they are related. Figure 6, p. 280.

What can the model predict from the published plots?

I worked in four steps. The scan preserves the original axes, labels and traces. The digitized points record the calibrated readings. PCHIP, a piecewise cubic interpolant, connects the nodes of each curve within its domain. The empirical equations use a small number of coefficients and have to predict points set aside from fitting. The six quantitative figures, numbered 3, 4, 5, 7, 8 and 9, contain ten panels, 53 reviewed traces and 2,443 digitized points. Ten Curve Fitter workspaces hold the accepted interpolants, which supplied 5,335 values for numerical readings and plots.

A nearly zero PCHIP residual at a node shows that the interpolant passes through that point. Line thickness and calibration still affect points from the same scan. The polyline that joins the resampled values has its own spacing, so on nearly vertical stretches, a reading from the polyline can differ from a direct evaluation of the PCHIP. In Figure 9, the saved 12 A interpolant uses t(M) because the time coordinate briefly runs backward by 0.02064 µs along the 131-point trace. The current regression instead uses the original pairs with t as the independent variable. Figure 9, p. 282.

How to identify the PCHIP for the 12 A trace

The fourth input series in Curve Fitter contains 131 points. The plot overlays the nodes and the interpolants. Select the fourth series in Residuals to see the time error on the vertical axis and current magnitude on the horizontal axis. Under Parameters & Statistics, the model is listed as X = f(Y), with a nodal RMS residual of about 9.7 × 10−18 µs. This is numerical agreement at the nodes. The decay test below instead measures the current error on held-out points.

From digitized points to the 12 A interpolant

Curve Fitter overlays the nodes and interpolants from Figure 9, with the 131-point series selected.
Nodes overlaid on the accepted curve. Workspace idoc_4918864081895173, Figure 9. The 12 A input series is selected. Both axes are linear in this view. Plot p0040 uses a logarithmic vertical axis to show the current over several orders of magnitude.
The residual in interpolated time is plotted against current magnitude, with the nodal values listed below.
Residuals at the nodes, in µs. The native panel uses observed minus interpolated. The predictive models in this article use predicted minus digitized.
The PCHIP statistics show the X = f(Y) orientation and 131 observations.
Which variable the interpolant predicts. X is time in µs and Y is current in mA. The predictive test in mA measures a different error.

Before estimating the coefficients, I held out the entire 5 µs firing-threshold curve and the entire 120 µs recovery-threshold curve in each relevant family. In the other curves, I held out the contiguous block from fractional rank 0.43 to 0.56 after sorting by the independent variable. Each curve had the same total weight in least squares. I profiled candidate shape parameters and rotated three contiguous blocks for internal model selection. A more complex form had to improve the internal RMSE by at least 10%. In the final evaluation, each in-domain point contributed once to the external metrics. I define the residual as prediction minus the digitized value.

For a prediction between two pulse durations, I use the intersection of the anode-voltage ranges of the neighbouring training curves. The protocol does not evaluate predictions outside that common range. Values quoted in the RCA text provide a cross-check against the same experiment. Holding out an entire peak-current family tests whether the model carries over to a different discharge history.

GX-TXT records. The curve families are rca.2d21.1957.fig{k}.measurement_1.curves, the interpolants fit.2d21.rca1957.fig{k}.curve-famiglie, and the results dyn.2d21.rca1957.fig{k}. Here {k} identifies a panel such as 7b. The counts come from the final report 2d21-fitting/rca-1957. The 2d21-modello-dinamico dossier records the rules, domains and checksums in protocollo.md, domini.tsv and integrita.tsv.

One firing time, two thresholds

To read the original charts, I start at the anode voltage Va on the vertical axis and follow the trace for Ti to Vg1 on the horizontal axis, the actual G1-to-cathode voltage. Figure 3 gives the maximum required voltage to fire within the indicated time. Figure 5 gives the minimum voltage at which firing can occur. The plots give no frequency data from which to estimate quantiles or probabilities, and no cycle on a single tube from which to measure hysteresis. In both cases Rg1 is approximately zero. The labels 0 and +9 V refer to Ecc2, the supply upstream of the 1 kΩ resistor. The instantaneous G2 voltage depends on the screen current, which is unavailable. Figure 3, p. 275 · Figure 5, p. 277.

z = 200 V / Va − 1  ·  u = (5 µs / Ti)q
Vg1 = b0 + b1z + (b2 + b3z)u

Here z and u are dimensionless, and the coefficients b are in volts. The product zu lets the effect of pulse duration vary with anode voltage. A free asymptotic delay failed the selection criterion. Setting T∞ = 0 is a convention for this formula over the fitted domain. Solving for Ti requires Vg1 above the asymptote, and the result becomes sensitive near that boundary. In panel 5a, q = 0.25 reaches the lower bound of the search and rises as high as 0.40 when a training block is omitted. This test circuit supplies no static threshold measurement to pin down the asymptote.

Predicted voltage at 5 µs, with the entire duration held out
Panel and criterionqb₀, b₁, b₂, b₃ (V)In domain / totalRMSE (V)
3a, maximum, 0 V0.70−3.845 · 8.261 · 19.786 · −2.94929/301.280
3b, maximum, +9 V1−3.328 · 7.112 · 10.871 · −1.55830/322.038
5a, minimum, 0 V0.25−18.642 · 6.032 · 26.351 · −1.21356/570.904
5b, minimum, +9 V1−7.972 · 3.662 · 3.671 · 035/510.711

In the next plot I fix Va = 200 V and start with the upper curve. What does the model lose when I omit the entire 5 µs family? For the maximum I get 15.94 / 17.115 / about 17 V. For the minimum I get 7.71 / 7.905 / about 8 V. Each triplet gives the prediction with 5 µs held out, the accepted PCHIP reading from the full chart, and the value quoted in the RCA text, in that order. The residual panel compares the prediction with each in-domain digitized point. Maximum-threshold example, p. 275 · Minimum-threshold example, p. 277.

Two 5 µs firing thresholds at a 0 V screen supply, with residuals plotted against anode voltage.
The two thresholds at 5 µs. Plot Dataset export p0035 uses RCA panels 3a and 5a. Points are readings from the plots and lines are predictions. The lower panel shows the residual in volts for points within the model domain. The legend may show a dash even where plotted markers are circles.

Next I set Va = 125 V. Putting all four conditions on the same time axis shows that changing the screen supply shifts both thresholds. I obtained the descriptive cross-sections by intersecting the family PCHIPs with Va = 125 V within their respective domains. Transferring the model from 0 to +9 V and back gives RMSEs of about 6.45–7.06 V for the maximum (265 and 230 points) and 11.68–11.71 V for the minimum (248 and 293 points). In 5b, some traces cross locally by 0.041–0.081 V, while one pixel corresponds to about 0.13 V in the digitization. The local ordering near those crossings is therefore sensitive to scan resolution.

Two ways to read the data at 125 V on the anode

Four curves show the grid voltage required at different pulse durations with 125 V on the anode.
A cross-section at fixed anode voltage. Plot Dataset export p0036 shows the maximum and minimum criteria at both G2 supply settings. The lines are the four empirical equations over their covered ranges.
At 125 V anode voltage, symbols show the intersections read from the interpolants, with duration vertical and grid voltage horizontal.
Pulse durations read back from the charts. In Plot Dataset export p0037, each marker pairs a duration with the G1-to-cathode voltage read from the PCHIP of the full chart. Here the intersections are plotted with duration on the vertical axis.

GX-TXT records. dyn.2d21.rca1957.fig3a, .fig3b, .fig5a, .fig5b and .sezioni. Tables: parametri.tsv, metriche.tsv, sezioni.tsv, stabilita.tsv, trasferimento.tsv and controlli.tsv. domini.tsv lists the anode-voltage ranges and actual pulse durations for each family.

The grid pin needs 17 V. What must the driver supply?

In Figure 4, current rises with the G1 voltage. The quantity plotted in mA is the peak current drawn during the positive drive pulse before firing. GE’s quasi-static G1 characteristic for an unfired tube is in µA and was measured under different conditions. For the pulsed characteristic I used x = Vg1 / (1 V) and Ig1 / (1 mA) = b0 + b1 max(x − h, 0)1.25. Both h values lie below the lowest voltage on the respective curves. The equation describes the observed rise. The physical emission threshold remains undetermined. Figure 4, p. 276.

Positive grid current before firing, Figure 4
Ecc2b₀b₁hObserved Vg1 (V)
0 V−0.015510.006436−5−2.577…43.121
+9 V0.173520.005575−12−7.869…30.961

Across the two held-out blocks, 27 points in total, the model gives 0.00154 mA RMS and a maximum absolute error of 0.00330 mA. The table interpolated using the training points alone gives 0.000738 mA RMS on the same points. The lower panel keeps the residual scale in mA so the error can be read separately from the rise in current.

Peak grid current before firing and residuals in milliamps for the two screen-supply settings.
The current drawn from the pulse generator. Plot Dataset export p0038 is based on Figure 4. The horizontal axis is G1-to-cathode voltage. The legend gives the G2 supply setting upstream of 1 kΩ.

The +17 V point is useful for reading Figure 10. For Ecc2 = 0 V the equation gives +0.2912 mA. RCA uses +0.29 mA. Taking conventional current into the tube as positive gives Vs1 = Vg1 + Rg1Ig1. The 46.5 kΩ resistor in the example drops about +13.485 V using RCA’s rounded value. The driver therefore has to reach about +30.485 V during the pulse. From a −75 V bias, that is a swing of 105.485 V, or about 106 V. Using the current predicted by the equation gives 105.54 V. The pulse amplitude specified at the driver alone tells us little about the voltage at the grid pin. The resistor and bias are those in the RCA example. Figure 10, p. 282 · Driver calculation, p. 283.

GX-TXT records. dyn.2d21.rca1957.fig4, parametri.tsv, metriche.tsv, domini.tsv and controlli.tsv.

Four nearly parallel lines after the discharge

When the anode current stops, ions continue to reach G1. In Figure 9, time is plotted on a linear axis and the positive magnitude M, in mA, on a logarithmic axis. In the plot below I follow the 12 A trace. Equal vertical distances on this scale represent equal ratios of current. The trace is almost straight. Can one slope per trace predict the segment I left out?

M(t) = M0 exp(−t/τ)

I fitted ln(M/1 mA) as a linear function of t. The slope is −1/τ in natural logs and −1/(τ ln 10) in base-10 logs. M0 is the intercept converted back to current at t = 0. The first usable points already lie after zero. Figure 9, p. 282.

Single exponential: errors on the held-out blocks
Previous peak currentDigitized time window (µs)M₀ (mA)τ (µs)NRMSE (mA)RMSE (decades)
0.5 A0.191–70.9954.83118.311120.004040.00317
1 A0.249–88.3187.57020.435140.004070.00212
5 A0.045–112.45514.33722.648140.005220.00182
12 A0.119–128.92625.95823.178170.023640.00477

To look for curvature, I tested a stretched exponential, ln(M/1 mA) = b0 + b1(t/50 µs)β. It failed to meet the internal improvement criterion in all four families. For the 17 held-out points at 12 A, the RMSE is 0.00477 decades for the single exponential and 0.01466 decades for the stretched exponential. Leaving out different training blocks changes τ from 23.04 to 23.28 µs on the same scan. That range shows sensitivity to the points available. Measuring how τ varies between tubes would require a separate set of specimens. A double exponential remains to be fitted.

At 120 µs after a 12 A peak, the model gives 0.1465 mA, close to the 0.15 mA that the RCA authors read from their plot. I then held out the entire 5 A curve. I interpolated ln(M/1 mA) between the 1 and 12 A predictions, linearly in ln(Ipeak/1 A). The prediction covers 84 of the 109 points. I calculated two separate RMSEs on those same 84 points. The differences in current give 0.735 mA RMS, a measure of absolute current error. The differences in base-10 logarithms give 0.0505 decades RMS, a measure of error in the ratio of predicted to digitized current. The mean signed error is +0.481 mA. The prediction lies above much of the data. The four individual decay curves are described very precisely, but the prediction is less certain when the preceding peak current changes. Figure 9, p. 282 · Reading at 120 µs, p. 281.

Residual current within a trace and across peak currents

Four ion-current decay curves on semilogarithmic axes, with the candidate models compared on the 12 A trace.
One slope for each discharge history. Plot Dataset export p0040, from RCA Figure 9, shows linear time and logarithmic current magnitude. The digitized window at 12 A is 0.119–128.926 µs. On the 17-point held-out block, the single exponential gives 0.00477 decades RMS and the stretched exponential gives 0.01466.
Digitized 5 A decay data and a prediction from the 1 and 12 A curves, on a logarithmic current axis.
What happens when the 5 A curve is held out. Plot Dataset export p0042 shows the current-magnitude test. The prediction uses the 1 and 12 A curves over their common range.

GX-TXT records. dyn.2d21.rca1957.fig9, group 2 of .prova5a, metriche-candidati-congelati.tsv, diagnostica-locale.tsv, controlli.tsv and predizioni-corrente-esclusa.tsv. Here prova5a refers to 5 amperes.

When the grid regains control

I now turn to Figures 7 and 8. RCA plots the critical G1-to-cathode voltage on the horizontal axis and the reapplied anode probe voltage on the vertical axis, with one Tr per trace. The previous peak current determines which panel to use. With Rg1 approximately zero and the screen grid grounded through 1 kΩ, the response B is the actual G1-to-cathode voltage at the threshold of refiring. The model here predicts a voltage. The values of τ above describe the decay of a current. Figure 7, p. 280 · Figure 8, p. 281.

z = (Va, probe − 200 V) / (100 V)  ·  u = exp[−(Tr − 100 µs)/h]
B = b0 + b1z + (b2 + b3z)u

I profiled h over a grid of candidate values. It is a time scale in the model for the voltage needed to prevent refiring. When the entire 120 µs family is held out, the results depend strongly on the previous peak current.

Blocking voltage at 120 µs, with the entire duration held out
Peak currenth (µs)b₀, b₁, b₂, b₃ (V)In domain / totalRMSE (V)Mean signed error (V)
0.5 A40−2.564 · −0.464 · −26.548 · −1.15942/433.213−3.19
1 A25−3.043 · −0.993 · −24.567 · −0.63330/324.956+4.94
5 A40−2.622 · −1.129 · −70.302 · −0.49944/467.895−7.85
12 A40−2.937 · −0.867 · −50.012 · −2.2090/43UnavailableUnavailable

At a probe voltage of 200 V, I follow the 5 A trace. At 120 µs the candidate, fitted with that entire duration held out, calls for −45.26 V. The PCHIP from the full plot gives −37.939 V, and the RCA text gives about −38 V. The difference, about −7.3 V at this operating point, means the candidate calls for a more negative grid voltage than was necessary in the experiment. In the lower panel the residuals against the individual digitized points stay negative for the 5 A panel, with a mean of −7.85 V. That mean uses all 44 in-domain points. The −7.3 V difference compares two values at 200 V. Figure 7b, p. 280 · 5 A example, p. 279.

At 12 A, RCA Figure 7a contains 43 readings at 120 µs. At 200 V the full-plot PCHIP gives −67.615 V, while the RCA text says about −68 V. Once 120 µs is held out, the shortest duration available for fitting is 150 µs. All 43 readings are therefore outside the prediction domain for this test. Plot p0039 shows only the 0.5, 1 and 5 A peak currents. The 12 A points remain in Figure 7a. The predictive table built using only the training durations is also distinct from the PCHIP based on the full curve.

Upper panel: measured and predicted blocking voltages for 0.5, 1 and 5 A peaks. Lower panel: residuals in volts.
Where the prediction calls for too much negative bias. Plot Dataset export p0039 shows the points and predictions for 0.5, 1 and 5 A in the upper panel. In the lower panel, the 5 A residuals are negative. All 43 readings at 12 A and 120 µs in Figure 7a lie outside the prediction domain and are omitted from the plot.
Open the GX-TXT view of the 120 µs test
GX-TXT shows the plot controls and both panels for the 0.5, 1 and 5 A blocking tests at 120 µs.
The same test in the GX-TXT window. The screenshot shows the view controls and both panels of p0039. The legend lists the three peak currents shown: 0.5, 1 and 5 A.

I also tried predicting the voltage when the entire 5 A peak-current family was held out. Interpolating the voltage predictions at 1 and 12 A against log peak current gives 1.63 V RMS on 58 of 143 points, at 200 and 500 µs only. Plot p0041 shows this test. The earlier test in mA used a different response, a different axis and 84 points. To reproduce a documented curve, I use its own interpolant. The prediction tests are still insufficient to support a blocking-voltage surface for arbitrary discharge histories.

The predicted blocking voltage for a 5 A peak is compared with the RCA points at 200 and 500 µs.
Transferring the voltage prediction. In Plot Dataset export p0041, the horizontal axis is the anode probe voltage. Only the two durations with a common prediction domain are shown.

GX-TXT records. dyn.2d21.rca1957.fig7a, .fig7b, .fig8a, .fig8b and group 1 of .prova5a. Tables: parametri.tsv, metriche.tsv, domini.tsv, diagnostica-locale.tsv and trasferimento.tsv.

Ions shift the grid voltage. How much does that explain?

I return to the Figure 10 resistor at a different point in the cycle. With current into the tube defined as positive, Ig1 = −M during recovery, so Vg1 = Vs1 + Rg1M. With a bias of −75 V, 46.5 kΩ and a current magnitude of 0.15 mA, the grid pin rises to about −68 V. This follows from the external circuit. To see whether M explains the tube’s blocking threshold B, we would have to vary M and measure the resulting change in the threshold under otherwise comparable conditions. Figures 9–10, p. 282 · Calculation on p. 283.

Aligning the measurement windows yields 116 points for B, but the probe voltage varies at only three combinations of previous peak current and delay: 12 A at 120 µs (43 points), 5 A at 100 µs (36) and 1 A at 80 µs (37). There is no overlap at 0.5 A. Each combination supplies just one value of M. The probe voltage varies, but M is constant within each peak-current group. Adding it to the three peak-specific intercepts and the anode-voltage term gives five regression columns and rank four. The intercepts account for its entire contribution. The baseline without M gave 1.64 V RMS on the 116 points.

This design leaves the separate contribution of M unidentified. To resolve the physical relationship, we would need several common delays at each peak current and probe voltage, repeated across multiple peak currents. In 1959, Adati and Sawa found that prior bias mattered most for the shortest firing pulses. The repetition period may affect the response to the next command even after the recovery time defined by the blocking test. Their results broaden the question. They were not used in the regression on the RCA data. Adati and Sawa, pp. 590–596.

GX-TXT records. Blocking-voltage datasets dyn.2d21.rca1957.fig7a, .fig7b, .fig8a and .fig8b, and current dataset .fig9. The comparison is in legame.tsv and controlli.tsv.

What I would put into a four-terminal model

Back at the receiver schematic, I can now identify what remains to be measured at each terminal. A is the anode, G1 the control grid, G2 the screen grid and K the reference cathode. The meaning of the G1 current changes over the cycle. The sources use different G2 conditions. Documenting those conditions next to each submodel keeps the original test circuits and operating regimes explicit.

Available submodels and quantities still to be measured
Operating regimeAvailable description and test conditionsWhat remains to be determined
Quasi-static off stateGE G1 current with G2 tied to the cathode, at anode voltages of 25, 200, 400 and 600 V. The GE static threshold is specified at the G1 source with 100 kΩ in series.Interpreting the source threshold requires the specified drive circuit and the corresponding grid current.
Grid driveRCA current and firing envelopes for rectangular pulses, with two G2 supply settings through 1 kΩ.Arbitrary pulse shapes and instantaneous screen current still need to be characterized.
On stateG1 current during sustained discharge, over the Level-1 model’s domain.Anode current and on-state voltage drop are needed to reconstruct the discharge history imposed by the load.
ExtinctionThe observed end of the anode current sets the origin of Tr.Holding current and self-extinction require their own test conditions.
RecoveryTwo outputs, M and B, with different domains in peak current, delay and probe voltage.The relationship between the two outputs and the actual operating conditions of the Zenith coil remain open.

In Zabb’s macromodel, G2 is tied to K. Its RC network is a pre-existing circuit choice. The RC time constant and the values of τ from Figure 9 describe different things. In this analysis, a single exponential describes decay accurately within each discharge history. The 5 A, 120 µs result shows how far a blocking-voltage formula can still miss. I would carry that distinction back to the Flash-Matic coil, once the actual currents, waveforms and margins of the receiver circuit are known. Level-1 model for sustained discharge · Review, especially Chapters 7–9 and 16–17.

Tracing the calculation and its sources

The model identification is stored in Octave Script Workspace as session:id-dinamica-2d21-rca. The completed job script-20261123T032746Z-2783801-1795404466014798 preserves the script that ran and its tables. The source SHA-256 is 5087557b6c96d9aba015b11a4dc01536cbdad3729b570856eafcc57a86c845c7. The comparison of the previously fitted forms uses session:valutazione-candidati-2d21-rca. In the results datasets, split identifies training points (0), a held-out block (1) or an entirely held-out duration (2). supported flags predictions within the evaluation domain. The prediction and residual have the same units as the response. Out-of-domain values are left missing. The dataset note identifies the RCA panel and the quantity digitized.

The saved script and completed job

Octave Script Workspace shows the script identifier and the lines that hold out blocks and entire durations.
How the script partitions the data. In Octave Script Workspace, fractional ranks from 0.43 to 0.56 define the held-out block. The following lines hold out all observations at 5 or 120 µs in the relevant families.
Session Files lists the analysis artifacts and the Octave report with the PASS result and the script checksum.
The archived computation. The job report lists GNU Octave 9.4.0, the script reference, its checksum and a PASS result. Its artifacts include the executed script, the ten panel tables and the metrics.
Trace a prediction to its row in Figure 7b

In the Figure 7b table I follow the rows at 120 µs. The flag split = 2 marks the entire duration as held out. In row 39 the probe is about 56.73 V, the residual is −9.89 V and supported = 1. Rows 37–38 have the same delay and lower probe voltages. They fall outside the domain and have no residual. The 200 V comparison above uses a different probe voltage.

From the Figure 7b table to its dataset note

The table shows probe voltage, G1 voltage, the 120 µs delay, prediction, residual, split and support flag.
Checking the prediction row by row. Dataset dyn.2d21.rca1957.fig7b. The highlighted row is within the evaluation domain at 120 µs in the family with a previous peak current of 5 A.
The dataset note cites the RCA source and explains blocking voltage and the validation split codes.
The accompanying note. In Session Files, the note cites Olmstead and Roth, identifies the anode probe and G1 pin voltages relative to the cathode, and states the convention for residuals in volts.

Plots p0035–p0042 are native Plot Dataset exports. The screenshots show the plot window, interpolant, data table and details of the saved computation. The original 1957 circuits and graphs can be consulted in the issue at the pages and figure numbers cited above.

  • J. A. Olmstead and M. Roth, Pulse-Firing Time and Recovery Time of the 2D21 Thyratron, RCA Review XVIII, no. 2, June 1957, pp. 272–284. Original issue.
  • Adati and Sawa, Pulse-firing Characteristics of 2D21 Thyratron, 1959, pp. 590–596. DOI 10.11499/sicejl1951.9.590.

#2D21 #discharge recovery #grid current #GX-TXT #historical electronics #pulse firing #thyratron

Other steps of this project

Leave a Reply

Your email address will not be published. Required fields are marked *