Circuits and frequency response
Series RLC
Open Study → Series RLC frequency response…. Fill in Resistance (Ohm), Inductance (H), Capacitance (F), Frequency unit and Frequency samples. Enter positive physical values. Choose Hz for cyclic frequency or rad/s for angular frequency. The frequencies must be positive, distinct and increasing. With 100 Ω, 0.01 H and 1e-6 F the ideal resonance is 10,000 rad/s, about 1,591.55 Hz.
With the angular frequencies 100, 1,000, 10,000 and 100,000 rad/s and with the physically equivalent frequencies in Hz the review gave the same summary, from −39.956791 to +0.043209395 dB. A list that is duplicated, decreasing or contains 0 is rejected. Use Review response to read the magnitude of the input impedance, the gain 20 log10(|Vc/Vin|) and the continuous phase in degrees. With the initial list 10 30 100 300 1000 3000 10000 Hz the test gave from −31.818627 to +1.1857519 dB. To publish, enter a free New Dataset ID and Graph title, then Publish Graph. The test created math_guide_rlc and plot.dataset.xy/p0001. The Dataset includes complex quantities as real and imaginary columns. Use Plots to reopen magnitude and phase.





Parallel RLC
Open Parallel RLC current response…. The resistance, inductance, capacitance and frequency fields follow the same units. The source is a current and the gain concerns Ir/Iin, the ratio between the current in the resistor and the input current. With 100 Ω, 0.01 H, 1 μF and 100 1000 10000 100000 rad/s, the test shows an impedance from 1.00005 to 100 Ω and a gain from −39.999566 to 0 dB. To compare the same point in Hz use f=ω/(2π).


Transfer functions
Open Continuous transfer response…. Stage A numerator coefficients and Stage A denominator coefficients contain lists in decreasing powers of s. Use proper stages, up to order 2 per stage, with valid denominators. Combination governs the presence of the B coefficients:
| Choice | Response |
|---|---|
| Single stage (A) | Computes A on its own. |
| Cascade (A then B) | Multiplies the responses. |
| Ideal parallel sum (A + B) | Adds the responses. |
| Ideal parallel difference (A − B) | Subtracts B from A. |
| Response quotient (A / B) | Divides A by B. Swap the inputs if you need B/A. A zero divisor prevents a quotient at that point. |
For the combinations also enter Stage B numerator coefficients and Stage B denominator coefficients. Give 2–512 increasing positive frequencies in Hz or rad/s and use Review response. Read poles, zeros, DC gain and the conditions reported. The roots are reported before cancellations. A pole on the evaluation axis, a degenerate denominator or an undefined quotient require you to inspect the diagnostics.
For the notch at 7 rad/s, enter numerator 1 0 49, denominator 1 4 49 and frequencies 1 4 7 10 20. The test shows H=0, gain −∞ and undefined phase at 7 rad/s. The Graph represents the finite observations, while the table output keeps the point and qualifies it with the validity flag. Publishing produced math_guide_notch and plot.dataset.xy/p0007. In the Dataset at 7 rad/s the values are transfer_real=0, transfer_imaginary=0, gain_db=-Inf, transfer_phase=NaN and bode_defined=0. Fill in New Dataset ID and Graph title, then use Publish Graph after the review.