In this guide, we reconstruct two scientific curves from the same image: the gain and phase responses of an RC low-pass filter. We will configure a logarithmic X axis, assign the curves to two different Y axes, extract points using assisted tracing, and publish them as Datasets ready for further analysis.

We will work with a synthetic graph so that the results can be compared with a known mathematical model. The same steps apply to a graph taken from a paper, a scan, or an experimental image, provided the axis scales are known.

By the end, we will have: a Digitalizer configuration, two curves with 100 points each, two Datasets with different physical units, an optional Dataset Group, an uncertainty declaration, and the identifiers needed to trace every point back to the raster image.

1. Prepare the Graph and Read the Axes Correctly

The original graph shows the frequency response of a first-order RC low-pass filter. The blue line is gain in decibels; the red line is phase in degrees. Both depend on frequency, but they have different units and must not be interpreted against the same vertical axis.

Pink semilog graph showing the blue gain curve and red phase curve of an RC low-pass filter.
Starting graph: gain and phase of an RC low-pass filter with a logarithmic frequency axis.
AxisQuantityRangeScale type
XFrequency (Hz)10 – 100,000Logarithmic
Y1Gain (dB)−40 – +5Linear
Y2Phase (°)−100 – +10Linear

The reference circuit has a resistance of \(R=10\,\mathrm{k}\Omega\) and a capacitance of \(C=10\,\mathrm{nF}\). Its theoretical cutoff frequency is:

$$f_c=\frac{1}{2\pi RC}\approx1591.55\,\mathrm{Hz}$$

The two functions we want to reconstruct are:

$$G_{\mathrm{dB}}(f)=-10\log_{10}\!\left[1+\left(\frac{f}{f_c}\right)^2\right]$$

$$\varphi(f)=-\arctan\!\left(\frac{f}{f_c}\right)\frac{180}{\pi}$$

You do not need these equations to operate the Digitalizer, but they help you interpret the result: gain approaches 0 dB at low frequencies and decreases above the cutoff frequency, while phase gradually changes from 0° toward −90°.

2. Import the Image into the Session

Open a GX-TXT Session and use the standard acq.image_binary acquisition workflow to import the PNG image. This creates an Image Dataset, rather than leaving the image disconnected from the Session data.

Before continuing, check that the correct image has been imported, that it has not been accidentally cropped or resized, and that the axes are readable. The example image is 1600 × 900 pixels.

GX-TXT interface showing the graph image imported as a Dataset and available to Curve Digitalizer.
Importing the raster graph into the GX-TXT Session.

Open Viewers → Curve Digitalizer, create a configuration, and select the newly imported Image Dataset as the source. Selecting the source from the Session catalog preserves the link between the image and the numerical results.

3. Configure X, Y1, and Y2

Go to the Calibration tab. First define the physical meaning of the coordinates. Enter the ranges from the table above and select the scale type for each axis:

  • X: Frequency, unit Hz, minimum 10, maximum 100000, log scale.
  • Y1: Gain, unit dB, minimum −40, maximum +5, linear scale.
  • Y2: enable the second axis, Phase, unit deg, minimum −100, maximum +10, linear scale.
Curve Digitalizer axis settings with logarithmic frequency X, linear gain Y1 and linear phase Y2.
Defining the physical scales and units of the three axes.

Important: when setting up a logarithmic axis, enter the actual values, not their logarithms. For frequency, enter 10 and 100000, not 1 and 5. The Digitalizer applies the logarithmic transformation.

Y1 and Y2 represent two physical interpretations of the same vertical position in the raster: a point at a given height may correspond to a value in dB or degrees, depending on the axis assigned to the curve.

Select the Four Corners

In the calibration section, identify the four corners of the plotting rectangle in the order specified by the interface: BL (bottom-left), BR (bottom-right), TL (top-left), and TR (top-right).

In the reference image, the plotting-region corners are near pixel coordinates BL (180, 755), BR (1400, 755), TL (180, 100), and TR (1400, 100). In the interface, select the points on the visible image rather than blindly copying coordinates from a table: a different scan may have different dimensions or margins.

Graph in Curve Digitalizer showing the four BL, BR, TL and TR calibration reference points.
Selecting the four corners of the plotting area.

Check that all four markers sit at the intersections of the plot boundaries, not at the center of a curve stroke. Accept the calibration when the geometry is consistent.

Check a Known Grid Point

Before placing curve guides, open Calibration verification and select a grid point whose physical coordinates are known. Choose the intersection at 1000 Hz, −10 dB gain, and approximately −26.667° phase.

In the frequency field, you can enter 1e3, meaning 1000. The verification panel shows the values calculated by the geometric transformation; compare them with the reference values.

Curve Digitalizer verification panel comparing expected and calculated coordinates on X, Y1 and Y2.
Checking physical coordinates after calibration.
CoordinateReferenceExample calculated value
X1000 Hz1000.035 Hz
Y1−10 dB−10.00194 dB
Y2−26.667°−26.6714°

Small differences in this check indicate that the selected point is consistent with the calibration. If a value is substantially different, first check the positions of the corners, then the axis limits and scale types. Do not start digitizing with an obviously incorrect calibration.

4. Create and Digitize the Gain Curve (Y1)

Open Curves and add a new curve named Gain. Select Y1 as its vertical axis: this determines which physical scale is used to convert pixel positions into decibels.

For a frequency response progressing from left to right, set Monotonicity → Monotonic in X and Point ordering source → Sort by X. The first constraint prevents unwanted backward steps along the frequency axis; the second orders extracted points by X, even if the guides were placed in a different order.

Digitizer settings showing Monotonic in X and Sort by X for curve point ordering.
Configuring monotonicity and point ordering along X.

These settings are not suitable for every graph: closed curves or paths that move back to the left require a different tracing behavior.

Place the Guides

Activate Add guide and place a few well-spaced reference points along the blue line. You can start near 100 Hz, 1 kHz, 10 kHz, and 50 kHz, then add guides near the endpoints. Guides indicate the path to follow; they do not need to represent every final point.

RC filter graph with guides placed on the blue gain curve for assisted tracing.
Placing guide points along the Gain curve assigned to Y1.

Click Propose to generate the suggested trace. Pay particular attention where the curve changes slope, approaches grid lines, or crosses other lines: in these regions, the algorithm may choose an unintended path.

Adjust Step and Corridor

The proposal also depends on the search parameters. In this example, keep Step = 2 px and compare two Corridor values: 1 px and 4 px.

Gain curve tracing proposal using Corridor set to 1 px and Step set to 2 px.
First tracing proposal with Corridor = 1 px.
Gain curve tracing proposal using Corridor set to 4 px and Step set to 2 px.
Second tracing proposal with Corridor = 4 px.

A narrow corridor keeps the search close to the guide path; widening it gives the algorithm more room to follow the raster line. However, an overly wide corridor may include unwanted elements, such as grid lines or the second curve. No single Corridor value is optimal for every image: inspect the result and choose the value that follows the target line most closely.

Correct the Proposal Before Accepting It

If part of the path drifts away from the blue line, use Edit proposal to add the required correction points. Regenerate or update the proposal, then inspect the entire path. Correcting a few guide points is easier than manually editing a hundred already-published points.

Curve Digitalizer in Edit proposal mode while manually correcting the proposed tracing path.
Correcting the path before accepting the points.

When the trace looks satisfactory, set Output points (Accept) = 100 and click Accept. The curve is recorded as Gain / Y1 / 100 points.

Curve Digitalizer showing the Gain curve assigned to Y1 with 100 accepted digitized points.
Gain tracing result: 100 accepted points.

The number of points defines the sampling density along the accepted trace. It does not directly measure accuracy: adding more points will not fix a poorly followed curve.

5. Digitize Phase (Y2) and Use Undo

Add a second curve named Phase and assign it to Y2. The workflow is the same: place guides along the red line, generate a proposal, inspect it, and select an output of 100 points.

Checking the endpoints is especially important here: phase approaches −90° at high frequencies, while gain uses a completely different scale. A curve mistakenly assigned to Y1 might appear correctly positioned on the raster yet have incorrect physical coordinates.

Suppose you accept a proposal and then notice that the final section does not follow the red line correctly. The following image shows the type of error to look for.

Phase curve tracing showing an incorrect final section that requires correction.
Identifying an incorrect section in the Phase tracing path.

Use Undo to restore the state before acceptance, then return to Edit proposal. Add or reposition the necessary guides, inspect the new path, and click Accept again.

Curve Digitalizer after Undo, with the Phase tracing proposal being edited.
Restoring and correcting the Phase tracing path.

The curve list should now show Gain / Y1 / 100 points and Phase / Y2 / 100 points: 200 points in total, representing two distinct physical quantities.

Graph showing digitized Gain and Phase curves with a total of 200 accepted points.
Both digitized curves: 100 Gain points and 100 Phase points.

6. Publish the Curves as Scientific Datasets

Open the Publish tab and select the calibration you have just used. To create the first pair of Datasets, choose the Separate layout and leave Group published Datasets disabled for now.

Enter a new base identifier for this publication. This makes the outputs easy to identify and prevents confusion with any existing Datasets.

The publication produces two separate results:

  • Gain Dataset (Y1): frequency in Hz and gain in dB, 100 rows.
  • Phase Dataset (Y2): frequency in Hz and phase in degrees, 100 rows.
GX-TXT showing two separately published Datasets for Gain on Y1 and Phase on Y2.
Publishing Gain and Phase as separate Datasets.

The Datasets also contain traceability information, including the logical axis y_axis_id, the curve name and identifier, the point index and identifier, and the pixel coordinates pixel_x and pixel_y. Publishing makes the points available to other GX-TXT tools without having to read the image again.

Why two Datasets? The quantities use different units. Keeping dB and degrees separate prevents a single unit from being mistakenly assigned to both ordinates.

7. View the Results in Dataset Preview

Select the Gain Dataset in the catalog and open Dataset Preview. To display the curves with the configured physical scales, use the Curves tab and Load curves. Repeat the procedure for the Phase Dataset.

GX-TXT specialized Preview displaying Gain against logarithmic frequency with gain expressed in dB.
Gain curve displayed in the specialized Preview.
GX-TXT specialized Preview displaying Phase against logarithmic frequency with phase expressed in degrees.
Phase curve displayed in the specialized Preview.

Check three things: frequency must use a logarithmic scale; the first Dataset must use dB; and the second must use degrees. A curve that looks plausible is not sufficient if the physical axis is wrong.

The interface may also provide a generic Plot tab and other views. For this exercise, explicitly select Curves, which displays the curves using the scales declared by the calibration. The Canonical Data tab lets you read the numerical row values directly.

8. Group Gain and Phase Without Mixing Units

If you want to keep both results together, return to Publish, choose a new base identifier, and enable Group published Datasets. Keep the Separate layout and publish the curves again.

You will obtain a Dataset Group with two members: one for Gain/Y1 and the other for Phase/Y2. The group is a logical container: it does not place decibels and degrees into a single column, change curve values, or remove the identity of its member Datasets.

GX-TXT Preview of a Dataset Group containing the Gain Y1 and Phase Y2 Datasets.
Grouping the two Datasets without combining incompatible physical units.

This feature is useful when several quantities belong to the same experiment or image and need to be found and inspected together.

9. Declare Digitization Uncertainty

So far, we have converted positions identified on an image into physical coordinates. Locating the center of a raster line and the grid corners is not perfectly precise: to describe this limitation quantitatively, we can add an explicit uncertainty model.

Open Publish → Uncertainty… and select pixel_calibration. For this exercise, use the rectangular_full_width distribution, two total widths of 2 px, and the following calibration standard uncertainties:

FieldValue to enter
Error modelpixel_calibration
Pixel scale meaningrectangular_full_width
Pixel X/Y widths2 2
8 corners + 6 axis endpoints0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0 0 0 0 0 0
Physical X/Y1/Y2 standard uncertaintiesLeave blank for the selected model

The first eight numbers specify the standard uncertainties of the four corners’ pixel coordinates, in the order BL X/Y, BR X/Y, TL X/Y, TR X/Y. The final six numbers describe the physical minimum/maximum endpoints of X, Y1, and Y2. In this synthetic example, these endpoints are treated as exact by construction.

If point-position uncertainty is modeled by a rectangular distribution of total width \(w\), its standard uncertainty is:

$$u_{\mathrm{pixel}}=\frac{w}{\sqrt{12}}$$

A total width of 2 px corresponds to approximately 0.577 px. This is a declared assumption, not a quantity measured automatically by the software. For an experimental graph, select and justify the model according to the actual acquisition conditions.

In the Evidence / reason field, briefly describe the assumptions and click Apply and save declaration.

Curve Digitalizer Uncertainty dialog showing the pixel_calibration model and declared uncertainty parameters.
Configuring the pixel and calibration uncertainty model.

Publish and Read Standard Uncertainties and Covariance

The declaration does not retroactively change previously published Datasets. To obtain tables that include uncertainty, return to Publish and use a new base ID. Publish both curves again with the uncertainty model enabled.

Open Canonical Data in the Preview of the new Datasets. You will find three additional numerical columns:

  • sigma_x: frequency standard uncertainty, in Hz;
  • sigma_y: gain standard uncertainty in dB or phase standard uncertainty in degrees;
  • covariance_xy: covariance between frequency and the ordinate of the same row, expressed in the product of their units.
Phase Dataset Canonical Data table showing Sigma X, Sigma Y and Cov XY columns with numerical values.
Published standard uncertainties and X–Y covariance in the Phase Dataset.

The preceding screenshot shows the uncertainty columns of the Phase Dataset (Y2). As a further example, the first row of the Gain Dataset (Y1) contains the following numerical results:

QuantityValue
Frequency X10.05395227 Hz
Gain Y1−0.04282468 dB
σX0.05547460 Hz
σY10.05033129 dB
Cov(X,Y1)5.38250 × 10−5 Hz·dB

These numbers must be interpreted correctly: the calibration is shared by all points on a curve, so it may introduce correlations between different points. The uncertainty columns of a single row are not equivalent to a complete covariance matrix for all observations.

10. Trace Numerical Points Back to the Image

To check the origin of a value, open Canonical Data → Point traceability and load the table. You will find the curve identifier, the unique Point ID, the Calibration ID, and the original raster coordinates.

Point traceability table showing point identifiers, Calibration ID and pixel coordinates for the Gain Dataset.
Original identifiers and raster coordinates of digitized points.

These fields answer practical questions: Which curve produced this row? Which raster point was digitized? Which calibration was used to calculate its physical coordinates?

The table also provides pagination and selectable numerical precision. Changing the number of displayed digits does not alter the values stored in the Dataset.

11. Final Checks and Reusing the Datasets

Before using the results in another script or plot, check that the work is complete:

  • The two curves are assigned to the correct axes: Gain → Y1 and Phase → Y2.
  • The calibration uses a logarithmic X scale, and the physical ranges match the original graph.
  • Each published Dataset contains 100 rows, without mixing degrees and decibels.
  • The Curves Preview displays the axes correctly, while Canonical Data shows the values.
  • The uncertainty-enabled tables contain sigma_x, sigma_y, and covariance_xy, and the rationale for the model is saved.
  • Point IDs, calibration identifiers, and raster coordinates are available in the traceability section.

Save the Session using the standard GX-TXT commands. When you reopen the work, you can retrieve the Digitalizer configurations and published Datasets from the Session catalog.

You can use the Datasets to compare results with the RC model, create further Plot Dataset visualizations, process values through Script Bridge, or perform other scientific operations available in the framework. Digitization does not merely produce another drawing: it produces numerical values with units, identities, and provenance.

#Curve Digitalizer #curve tracing #data traceability #Dataset Group #dual Y-axis #graph digitization #GX-TXT #logarithmic calibration #Plot Dataset API v4 #RC low-pass filter #Scientific Datasets #scientific graph digitization #uncertainty propagation