From the Zenith Flash-Matic remote control to the historical measurements of the 2D21 thyratron: a research path through experiments, mathematical models and problems that are still open.

When I started studying the receiver of the 1956 Zenith Flash-Matic, I asked myself a question: would it be possible to reconstruct how it worked through an electronic simulation?

I decided to take on this work for two reasons. The first is that, searching the technical and scientific literature, I did not find a mathematical model of the 2D21 thyratron that was documented and complete enough for what I wanted to do. There are studies, models and many experimental measurements, but none of the ones I examined fully solved my problem. I described this literature search in the article The 2D21 Thyratron: From Historical Curves to SPICE Models.

The second reason concerns the history of remote controls. I would like to simulate the original Flash-Matic receiver, because I have not found a reconstruction of its operation through a circuit simulation. I think the story of how we got to modern remote controls deserves to be explored in depth, not only by describing how the first devices were built, but also by trying to understand and reproduce their behavior.

So I started from the characteristic curves in the General Electric datasheet of the 2D21. I digitized them, turning simple printed graphs into numerical data, and looked for a first mathematical relationship able to represent them. I described this work in the article 2D21 Thyratron: From GE Datasheet Curves to a Level-1 Compact Model.

The first result was encouraging. I noticed that the characteristics, although different, showed similarities: by suitably changing the scale and position of the curves, much of their shape could be traced back to a common mathematical structure. This gave me a first empirical model, called Level-1, able to describe the control-grid current during tube conduction fairly well, especially for anode currents between 25 and 200 mA.

Not all the characteristics were represented with the same accuracy, in particular the 300 mA one. But above all, that first model described only one aspect of how the thyratron works: it did not yet explain when the tube fires, how it behaves during a pulse, and how long it takes to recover the ability to block a new discharge.

To get closer to simulating the Flash-Matic, I therefore had to tackle these problems as well.

How does the 2D21 thyratron work?

The 2D21 is a particular kind of electron tube called a thyratron. Unlike ordinary thermionic tubes, which work in a vacuum, it contains a small amount of xenon gas at low pressure. The gas is essential, because it makes it possible to start a controlled electrical discharge.

To better understand how it works, let us look at a drawing of its internal structure.

Inside the envelope we find the cathode (6), heated by an element called the heater (5). When it reaches operating temperature, the cathode emits electrons. The anode (7) is the electrode the electrons travel toward when the tube conducts.

The control grid G1 (2) is an internal structure that adjusts the electric field in the region the electrons pass through, and therefore controls the conditions under which the discharge is triggered.

The shield grid G2 (3) is shown as an outer metal structure, visible on both sides of the electrode assembly. The two labels with the number 3 refer to the same grid. The voltage applied to G2 also affects the conditions needed to fire the thyratron.

The drawing also shows the anode insulators (1) and the connection of the cathode to its base pin (4).

The xenon gas is not shown: it fills the free space inside the envelope.

Now let us see how these elements work together.

When the cathode is hot and we apply a positive voltage to the anode, the electrons emitted by the cathode tend to move toward it. However, the two grids can oppose this motion and prevent a significant discharge from developing in the gas.

In particular, by keeping the control grid G1 sufficiently negative with respect to the cathode, we can hold the thyratron cut off, that is, off. The voltage applied to the shield grid G2 also affects the firing conditions.

What happens, instead, when we want to fire it?

By suitably changing the voltage of G1, for example with a positive pulse, we allow more electrons to cross the grid region. If the conditions are sufficient, some electrons, accelerated by the electric field, strike xenon atoms with enough energy to knock out further electrons.

This process is called ionization: each ionizing collision produces an additional electron and a positive ion. The freed electrons can cause new collisions, rapidly increasing the number of charged particles in the gas.

At this point an electrical discharge develops and the current between cathode and anode rises abruptly.

But something very important also happens: the positive ions produced by the discharge change the electric field in the control-grid region, reducing its ability to stop the current.

This is why, once fired, the thyratron can keep conducting even after we remove the pulse that fired it. And this is where the thyratron shows a peculiar feature.

Once the discharge has started, the grid loses most of its ability to control the current. Even if the pulse that fired it is removed, the tube can keep conducting as long as the circuit maintains a sufficient anode current.

To turn it off, then, it is normally not enough to bring G1 back to its initial voltage: the anode current must be reduced or interrupted, so that the discharge can no longer sustain itself.

But even after turn-off, the gas does not return instantly to its initial conditions. Charged particles remain for some time, and are gradually neutralized or collected by the electrodes.

This means that the tube temporarily retains the effects of the previous discharge. Its ability to prevent a new firing is restored gradually: this is the phenomenon we call recovery of grid control.

We can therefore picture the thyratron as an electronic switch that is turned on by a command, stays on as long as the current allows it, and, after turning off, needs some time to fully recover its operating conditions.

It is precisely this sequence of events — firing, conduction, turn-off and recovery — that we must be able to represent if we want to simulate the Zenith Flash-Matic receiver correctly.

A concrete example of how the 2D21 works can be found in an experiment published on Hackaday in 2019 by microwavemont.

The author built a simple relaxation oscillator using a 2D21 thyratron and photographed on the oscilloscope the voltage produced by the circuit. The waveform shows the gradual charging of the capacitor and its rapid discharge when the thyratron starts conducting.

The experiment is particularly interesting because it shows the behavior of a real device, not the result of a simulation.

Thyratron experiment — microwavemont, Hackaday (2019)

Why is the 2D21 hard to simulate?

So far the thyratron might look like a rather peculiar electronic switch: a pulse turns it on, the anode current keeps it conducting and, when that current falls below the value needed to sustain the discharge, the tube turns off.

But if I want to reproduce its behavior in a simulation, this information is not enough.

For example, how long must the pulse applied to the grid last to fire the tube? And how long does the tube actually take to fire?

Then there is a second problem. We have seen that, after turn-off, the gas keeps some charged particles for a while. How does the thyratron’s behavior change if I try to fire it again immediately, instead of waiting longer?

To answer these questions, knowing the tube’s circuit diagram is not enough. We need experimental measurements describing its behavior over time.

That is why I began searching the scientific literature not only for the electrical characteristics of the 2D21, but also for experiments on its firing and on its recovery after turn-off.

The 1957 measurements: firing and recovery of the 2D21

Searching the scientific literature, I found a particularly interesting paper published in June 1957 in RCA Review. The article, titled Pulse-Firing Time and Recovery Time of the 2D21 Thyratron, is by J. A. Olmstead and M. Roth.

The two researchers had tackled precisely some of the problems I was interested in: how long does the 2D21 take to fire, and how much time must pass after turn-off before the grid can once again prevent a discharge?

To study firing, they had built an experimental circuit that applied electrical pulses to the control grid G1, varying their voltage and duration. They could also change the anode voltage and the supply of the shield grid G2.

This allowed them to answer a very concrete question: if I apply a pulse of a given duration to the grid, what voltage is needed to fire the tube?

They had observed that the two factors are linked. A very short pulse generally requires a higher drive voltage, while a longer pulse can fire the tube even with a lower voltage.

The second group of experiments concerned what happens after the tube turns off.

The researchers let the thyratron conduct, interrupted the anode current and, after a preset time interval, applied a voltage to the anode again. By adjusting the voltage of grid G1, they determined the value needed to prevent the thyratron from firing again.

They repeated these tests varying both the time elapsed since turn-off and the anode current that had flowed through the tube before the interruption.

The result is particularly interesting, as the original graphs of the experiment show.

To understand what the curves mean, consider an example: 120 microseconds after turn-off, with 200 V reapplied to the anode, a grid voltage of about −68 V is needed if the previous discharge had reached 12 A, while about −38 V is enough if it had reached 5 A.

This tells us something important: the thyratron’s behavior after turn-off also depends on how intense the previous discharge was. Knowing the elapsed time is therefore not enough to tell whether the tube is ready to be controlled again.

But the experiments also provided another piece of information: the researchers had measured the residual ion current that kept reaching the grid after the discharge was interrupted.

Looking at this second graph we can notice two things. The first is that the residual current decreases over time. The second is that the higher the anode current before turn-off, the higher the residual current under the measured conditions.

I had therefore found two complementary pieces of information: how the residual current decreases, and how the grid recovers its ability to prevent a new firing.

At this point I wondered whether it would be possible to find mathematical equations able to represent these behaviors and, above all, to predict them under conditions different from those used to derive them.

To try, I first had to turn the historical graphs into numerical data.

But how accurate does our model need to be?

At this point I asked myself a question: do I need a mathematical model able to describe the behavior of the 2D21 under any condition, or is it enough to represent it correctly under the conditions in which it is used in the Zenith Flash-Matic receiver?

The second option seems more reasonable to me. My goal, after all, is not to build a universal model of the 2D21, but to simulate the operation of one specific historical device.

For example, the RCA experiments used previous anode currents as high as 5 and 12 amperes. But if the currents in the Zenith receiver were much lower, would it really make sense to try to reproduce with extreme accuracy the tube’s behavior after such intense discharges?

This does not mean we can settle for a rough model in every situation. Conditions close to firing and turn-off are particularly important, because even a small error in the voltage needed to trigger the discharge could make the difference between a remote control that responds and one that does not work.

So I need to understand the original circuit better, identify the voltages, currents and times actually involved, and decide which characteristics of the tube must be reproduced with greater accuracy.

In other words, I do not necessarily need to describe perfectly everything the 2D21 could do, but I must be able to predict well enough what it will do in the circuit I want to simulate.

From printed graphs to numerical data

So I had found some very interesting experimental measurements, but there was a practical problem: how could I use the graphs from a 1957 publication to build and test a mathematical model?

Today I am used to working with numerical data that I can import into a program, process and plot. In the paper by Olmstead and Roth, however, the results were available mostly as printed curves.

To recover this information I used GX-TXT, the software I am developing to organize and process scientific data.

The first step was digitizing the curves with the Curve Digitalizer module. The procedure consists of loading the image of the graph, setting the axis scales and selecting points along the experimental characteristics. The program then converts the positions of the points on the image into the corresponding numerical values of voltage, current or time.

Of course, this takes care. The original curves have a thickness, some are very close to each other and in places they overlap. So I checked and corrected the acquisitions, trying to represent the characteristics reported by the authors as faithfully as possible.

In the end I obtained 2,443 digitized points, spread over 53 experimental curves.

At this point I finally had numerical data to work on. But I still had only a set of points: to obtain a continuous representation of the characteristics I used another GX-TXT tool, the Curve Fitter.

This allowed me to reconstruct mathematically the shape of each curve, including between the digitized points.

Note, however: I had not yet found a model of how the 2D21 works. I had simply turned the historical characteristics into a numerical representation that I could query and compare.

The real search for the mathematical model would begin in the next step.

From experimental curves to a mathematical model

Once the experimental characteristics were reconstructed, I faced a new problem: how to go from a collection of curves to a mathematical model of the tube’s behavior?

The difference may seem minor, but it is actually fundamental.

With the Curve Fitter I had obtained curves passing through the digitized points, reproducing the original graphs very faithfully. However, this did not mean I had found a law able to predict what would happen under different conditions.

For example, I could reconstruct the characteristic of the 2D21 for a drive pulse lasting 10 microseconds. But would I have been able to predict the voltage needed to fire it with a 5-microsecond pulse, without using the measurements for that duration?

To answer this question I looked for relatively simple mathematical equations, able to describe not only the individual curves, but also how they change when the experimental conditions vary.

These equations contain some numbers, called parameters, which must be determined from the experimental data. This operation is called fitting: I look for the parameter values that bring the equation as close as possible to the measurements.

But how could I know whether the equation I had found really worked?

I used a procedure that is fairly easy to understand: I set aside part of the experimental data, without using it to determine the model parameters.

For the study of firing, for example, I excluded the characteristics for 5-microsecond pulses. I built the model using the other durations, and only afterward asked it to predict the results at 5 microseconds.

I followed a similar procedure for the recovery of grid control, holding back the measurements taken 120 microseconds after turn-off.

At that point I could compare the predictions of the equations with the data I had set aside.

This was the most interesting test of the whole work. An equation can reproduce very well the data used to build it, yet behave differently when asked to predict something it has not already seen.

And that is exactly what I observed: for some phenomena I obtained very convincing results, while for others differences emerged that deserve further study.

To make clearer what I mean, it helps to look at two concrete examples.

In the first case I obtained a very convincing result. In the second, the model showed limits that I still consider important.

The mathematical equations I used

How did I choose the equations to use? Did I find them in the scientific literature, or did I simply try formulas until I found one that seemed to work?

The answer is that I started from the shape of the experimental data and from some mathematical functions commonly used to describe physical phenomena.

The 1957 paper by Olmstead and Roth gave me the measurements, but not the empirical equations I present here. So I had to look for mathematical relationships suitable for representing them.

For example, looking at the graph of the residual ion current, I noticed that the curves become almost straight lines when the current is plotted on a logarithmic scale and time on a linear scale. This behavior suggests an exponential decay, a mathematical law that often appears in the description of relaxation phenomena.

For the recovery of grid control, the situation was more complicated. I had to describe a voltage that changes both with the time elapsed since turn-off and with the applied anode voltage. So I tried combining a dependence on anode voltage with a function describing how recovery evolves over time.

I did not stop at the first equation. I compared several mathematical forms, including some more complex ones, to check which were actually able to represent the data. I tried not to add parameters when they did not produce a significant improvement in the tests.

The equations I present are therefore empirical models: they describe the regularities observed in the experiments, without claiming to fully reconstruct all the microscopic processes taking place in the gas.

Let us see which relationships I used and what results I obtained.

The residual ion current

The first model concerns the residual current that keeps reaching the grid after the discharge is interrupted.

Looking at the experimental curves, I noticed that this current decreases rapidly over time. So I tried to represent it with an exponential decay law:

\[ M(t)=M_0\,e^{-t/\tau} \]

The formula contains only two parameters to be determined from the experimental data:

  • \(M_0\) is the residual current predicted by the model at the initial instant, immediately after the anode current is interrupted.
  • \(\tau\) is a time constant describing how fast the decay is.

The variable \(t\) is the time elapsed since turn-off, in microseconds, while \(M(t)\) is the absolute value of the residual current, in milliamperes.

The meaning of the formula is quite simple: the current decreases progressively, and how fast it decreases depends on the value of \(\tau\).

I determined the parameters separately for the four previous anode currents considered in the RCA experiments: 0.5, 1, 5 and 12 amperes.

For example, after a discharge with a peak anode current of 12 A, I obtained:

\[ M_0=25.958\ \mathrm{mA} \qquad \tau=23.178\ \mathrm{\mu s} \]

By substituting these values into the equation, I can calculate the predicted residual current at a given instant.

After 120 microseconds I get about 0.147 mA, very close to the 0.15 mA reported by the authors.

This is an example of how a simple equation can represent a set of experimental measurements. The parameters, however, change with the previous anode current: I did not find a universal time constant valid for every discharge.

The recovery of grid control

Describing how the grid recovers its ability to prevent a new firing turned out to be a more complex problem.

In this case, knowing the time elapsed since turn-off is not enough. The critical grid voltage also depends on the anode voltage that is reapplied and on the intensity of the previous discharge.

So I tried a mathematical relationship with more parameters:

\[ B=b_0+b_1z+(b_2+b_3z) \exp\left(-\frac{T_r-100\ \mathrm{\mu s}}{h}\right) \]

where:

\[ z=\frac{V_a-200\ \mathrm{V}}{100\ \mathrm{V}} \]

In this equation:

  • \(B\) is the critical voltage between grid G1 and cathode, in volts, marking the limit beyond which refiring can occur.
  • \(V_a\) is the anode voltage reapplied during the test.
  • \(T_r\) is the time elapsed since the previous anode current was interrupted.
  • \(b_0,b_1,b_2,b_3\) are coefficients determined by fitting the experimental data.
  • \(h\) is a time parameter governing how the critical voltage changes during recovery.

The quantity \(z\) simply expresses the anode voltage relative to a 200 V reference, which makes the model easier to build. Likewise, the 100-microsecond reference in the exponential is a mathematical choice for parameterizing the curves.

The equation therefore combines the effect of the anode voltage with that of the recovery time.

Here too I determined different parameters for the different previous anode currents.

To understand the result, let me take a concrete example.

After a 5 A discharge, with a test anode voltage of 200 V and a recovery time of 120 microseconds, the model predicts:

\[ B_{\mathrm{model}}\approx -45.26\ \mathrm{V} \]

The RCA measurements, instead, indicate a value of about:

\[ B_{\mathrm{RCA}}\approx -38\ \mathrm{V} \]

The difference is more than 7 V.

This is not necessarily a negligible error: if the circuit’s operation depended precisely on the grid’s ability to prevent refiring, a deviation of this size could change the outcome of the simulation.

What do these equations tell me?

The two formulas are built with the same criterion: choose a mathematical relationship, determine its parameters from the measurements and check how well it describes the experimental results.

But they did not give equally satisfactory results.

The decay of the residual current is represented very well by a simple exponential. The recovery of grid control, on the other hand, is harder and still needs further work.

This difference becomes evident in the comparison graphs between the points taken from the RCA publication and the curves predicted by my models.

A case where the model works well

The first example concerns the residual ion current after the thyratron turns off.

When the discharge stops, the gas inside the tube does not immediately return to its initial state. Charged particles remain for some time, and their presence shows up as a residual current that gradually decreases.

To describe this phenomenon I looked for a fairly simple mathematical law, then compared the curve predicted by the model with the data taken from the historical measurements.

In this case the result was particularly good. The curve predicted by the model follows the data well, showing that at least this aspect of the 2D21’s behavior can be represented convincingly.

For me this was an important result, because it shows that the residual ion current does not behave arbitrarily, but follows a regularity that the model captures fairly well.

A case where the model works less well

The second example concerns the recovery of grid control after turn-off.

Here too the starting idea was simple: look for a mathematical law able to describe how the grid voltage needed to prevent the thyratron from firing again changes over time.

After determining the model parameters, I compared the predicted curve with the experimental data in this case as well.

Here the result was less satisfactory. The model follows the general trend fairly well, but under some conditions it deviates significantly from the experimental values.

This means the model is not useless: it still describes part of the phenomenon. But it also means that, at least in this form, it cannot yet represent all aspects of grid-control recovery with sufficient accuracy.

And it is precisely this contrast that makes the overall result of the research interesting. In one case the model shows good descriptive and predictive ability; in the other it reveals that the real behavior of the 2D21 is more complex than the equation can yet represent.

For my goal — a credible simulation of the Zenith Flash-Matic receiver — this distinction is fundamental.

How I plan to continue the research

The work I have described so far is only a first phase of the research. I have managed to reconstruct numerically many experimental characteristics of the 2D21 and to obtain some promising mathematical models, but I cannot yet consider the work finished.

My next goal will be to look for more experimental information on the 2D21, especially in scientific publications and technical documentation of the period.

I am particularly interested in other graphs, oscillograms and measurements that could help me better understand firing, turn-off and recovery of grid control. I would also like to find experiments carried out under conditions different from those studied by Olmstead and Roth, to check whether the models I obtained can describe them.

A photograph of an oscilloscope screen, for example, can contain valuable information about how a phenomenon evolves over time. If I can find images that are legible enough and accompanied by the necessary experimental information, I will try to extract new data from them with the GX-TXT tools.

With a larger set of measurements I can try to improve the existing equations or look for different mathematical relationships, always comparing their predictions with the experimental results.

Of course, there is no guarantee that I will obtain a sufficiently accurate general model. The behavior of a gas thyratron depends on several physical phenomena, and it may be hard to reconstruct them all using only the measurements available in the historical literature.

If I reached that limit, I would still not consider the research finished.

I would then go back to my original goal: simulating the receiver of the 1956 Zenith Flash-Matic.

I will study the original circuit in more depth to identify the voltages, currents and characteristic times at which its two 2D21 thyratrons operate. This will let me establish which aspects of the tube’s behavior really matter for the receiver’s operation.

At that point I could build a simpler empirical model, limited to the operating conditions I am interested in, giving up on describing phenomena that play no part in the device’s operation.

Of course, this model will also have to be verified, and it will be important to distinguish the characteristics confirmed by experimental data from those I can only estimate.

If I manage to obtain a sufficiently reliable representation of the 2D21, the next step will be to integrate it into the simulation of the complete receiver, to study how the pulses generated by the photocells fired the thyratrons and actuated the solenoids that controlled the television set.

This is the result I would like to reach: reconstructing, with today’s tools, how one of the first wireless remote controls in the history of television worked.

For now I will keep looking for documentation, recovering data and testing the models. I will publish the results as the research progresses, including the difficulties and the solutions I manage to find.

Conclusion

This research is still open. I have recovered an important part of the experimental information on the 2D21 and used it to build and test some mathematical models. The results are encouraging, but they also show how hard it is to fully reconstruct the behavior of a gas tube starting from historical documentation.

I will therefore keep looking for new sources and testing the equations I have obtained, with the final goal of a reliable simulation of the 1956 Zenith Flash-Matic receiver.

For readers who want to go deeper into the scientific and mathematical side of the research, I have also published a technical article presenting in detail the 1957 measurements, the digitization procedure, the equations used, the fitting results and the comparisons between experimental values and predictions.

Firing and Recovery in the 2D21 Thyratron – From the 1957 RCA Tests to Mathematical Models

#2D21 #discharge recovery #GX-TXT #historical electronics #pulse firing #thyratron #Zenith Flash-Matic

Other steps of this project

Leave a Reply

Your email address will not be published. Required fields are marked *