Publishing the Dataset

Use this flow when you want to store the curve as data that can be used in the Session. The Workspace keeps the preparation of the work and is saved from the dedicated menu.

Result Dataset ID

At the bottom of the Builder replace built_curve with a new ID, for example profilo_livello_2d. It is the identifier with which you find the result in Datasets and plot windows. Use ASCII letters, numbers, points, dashes or underscores. The . and .. values are reserved. The spaces on the margins are removed. If the ID is empty or is already used, correct it and try again. The publication does not replace the existing Dataset.

Display name

The initial descriptive name is Built curve. Enter a readable description to identify the result in metadata or leave the blank field. The descriptive name may contain spaces and is independent of the ID.

Open Plot Dataset overlay after publication

The checkbox is selected by default. Leave it selected to open the result plot immediately. Uncheck it to save the Dataset without opening the plot. Either way, the result is available in the Session’s Dataset browser.

2D overlay
The standard editor Plot Dataset opens. Search for the derived Built curve series and compare it to the sources shown according to Options. The variant uses the XY representation, also for a parametric planar contour.
3D view
The interactive Native 3D representation of the standard line3 chart on X, Y and Z opens. The scene shows the derived line. Drag with the left button in the model window to rotate the path and use the wheel to approach or remove it.
Plot Dataset after publishing a 2D curve
The standard Plot Dataset window shows the result series along with the sources.
Parametric line in Native 3D after publication
Model window in Native 3D after publication of a parametric fit with the line method.

Publish as Dataset

  1. Mark rows and calculate a valid Preview.
  2. Fill Result Dataset ID and, if useful, Display name.
  3. Decide whether to open the chart and press Publish as Dataset.
  4. Check Published Dataset … in the status bar. Find the ID in the Session. After reopening, use that Dataset for further charts or analysis.

If Preview the selected curve before publishing. or Curve settings changed; preview again before publishing. appears, repeat Preview. If the source Dataset or schema has changed after preview, reload rows, mark again and repeat Preview. If the plots window fails after writing, check whether the ID exists in the Session before repeating the publication, because the opening of the chart follows the writing.

Dataset variables and provenance

An ordinary 2D result contains x and y. A parametric planar contour also contains t. A 3D result contains t, x, y and z. Units follow the source variables, with the curvilinear parameter using the common axis unit. The Dataset records the calculation type, degree, parameter mode, sample values, Dataset and variable identifiers, row ordinals, filters and processing order. It also stores the statistical results for statistical results.