Lines, Markers, Steps, and Uncertainties
GX-TXT P011-bis · Scientific Dataset Plot 4.4.2
In Analysis → Series… → Provider extension set Representation before editing Series style and the auxiliary variables. Save the series, start the new render and check which property changed the drawing.
Shapes and quick check
- Representation
auto- Procedure on the observations Dataset
- Leave the automatic representation and try Trace style → line or scatter in Configure.
- Result to look for
- The series follows the figure’s representation setting.
- Representation
line- Procedure on the observations Dataset
- Use
position_sandobservation_V, left axis. - Result to look for
- The samples are connected in the chosen order.
- Representation
scatter- Procedure on the observations Dataset
- Select marker
diamond, fillfull. - Result to look for
- Distinct filled diamonds, not connected.
- Representation
line_marker- Procedure on the observations Dataset
- Set
dashedand markersquare. - Result to look for
- Dashed line and squares on the points.
- Representation
step- Procedure on the observations Dataset
- Try
pre,mid,postin Step mode. - Result to look for
- The vertical transition moves to the start, the middle or the end of the interval between two samples.
- Representation
errorbar- Procedure on the observations Dataset
- Set Y error mode → symmetric and Y error →
v0009. - Result to look for
- Deviations of 0.2 V above and below each center value.
- Representation
band- Procedure on the observations Dataset
- Set Band lower →
v0007and Band upper →v0008. Toggle Draw center series with band. - Result to look for
- Area between the two limit columns. The checkbox adds or removes the center trace.
- Representation
bar,histogram,box_whisker- Procedure on the observations Dataset
- Follow the examples in the next chapter.
- Result to look for
- Bars for precomputed values or a derived distribution.
To redo the same series in several variants or with both renderers, run publication_lifecycle.py (ZIP) from Python Scripts. The recipe produces separate references and reports the step at which each case ends.
Per-series style
- Exact field
- Color
- Values and behavior
- Enter a hexadecimal RGB
#RRGGBBor open Choose color…. Automatic asks the renderer to differentiate the colors. Inherit reuses the inherited setting. The effect is visible when the plot is updated.
- Exact field
- Line style
- Values and behavior
autolets the renderer choose,inheritinherits,soliddraws a solid line,dasheddashed,dotteddotted,dashdotdash-dot,nonesuppresses the line. The scatter shape uses the marker.
- Exact field
- Line width
- Values and behavior
- Line width. Try 2.5 by entering
2.5. Inheritance uses the figure value. A positive width affects the drawn lines.
- Exact field
- Marker
- Values and behavior
auto,inherit,none,circle,square,diamond,triangle_up,triangle_down,plus,x,star. Choose a shape that is visible in scatter or line_marker.noneremoves the symbol.
- Exact field
- Marker size
- Values and behavior
- Positive size of the symbols. With a line without markers this setting is not visible.
- Exact field
- Marker fill
- Values and behavior
auto,inherit,noneorfull. Withcirclecompare a hollow and a filled shape.
- Exact field
- Opacity
- Values and behavior
- Opacity value between 0 and 1. To compare overlaps, use
0.5on a band and keep a center line.
X/Y errors, bands and limits
The section Auxiliary variable IDs (same dataset) lists the canonical IDs. For each axis, none omits the error. symmetric uses the same positive amplitude on both sides and requires the variable X error or Y error. asymmetric uses the columns X/Y error lower and X/Y error upper as amplitudes toward the two sides. For errorbar, set at least one of the two axes. The sample serie-filtri-errori.csv (ZIP) contains separate columns for the nine X/Y combinations. Look for the amplitude pair in the names xerr_low_s/xerr_high_s and yerr_low_mV/yerr_high_mV.
For band choose the two absolute limits, with units compatible with Y. For bar you can choose Bar X lower and Bar X upper for the exact width of each interval. Check that the limits are in the right order and that the domain is compatible with a logarithmic scale. If the fields do not share the same source, first register a Dataset with the required columns. For a legacy output with a right axis to be valid, at least one left-axis series must be active.
Test results