Run, Plot Status, and Data Reduction

GX-TXT P011-bis · Scientific Dataset Plot 4.4.2

The product specifies the desired output. The Run plan determines which modules are recomputed. Plots shows the rows and the state Use of the outputs. Check these three levels at the first rendering.

Plan, execution and state

  1. From Analysis, enable Run / recalculate now for Scientific Dataset Plot; then select the XY base, the rectangle base or both if they are configured.
  2. In Run, update the plan with Refresh plan. Check the selected module, current Dataset, products and dependencies. A disabled option indicates an input or a command that is not eligible in that context.
  3. Press Run enabled analyses. Follow the loading and rendering diagnostics. If an error appears, read the module’s first message. A row with no active series, a missing variable or an incompatible distribution blocks the corresponding output.
  4. In Plots, check that the row is YES in Use for the paths that require it, open the preview and check date and size. A previous PNG can stay visible across failed attempts. Changing the row selection displays the plot, while ticking the product determines what Analysis will request.

A local Rerender regenerates an already defined figure. When the Dataset or the module composition changes, repeat the Run and check which artifacts are new. In the menu Render distinguish the current action from the options for other plots or from the state not yet produced.

Reducing a large presentation

Mode
auto
Use
Leaves the choice to the renderer, with an initial threshold of 12000 valid rows.
Check
Compare the indications source_rows, valid, display and reduction in the summary.
Mode
none
Use
Requests the admitted data without presentation reduction.
Check
The display count follows the valid samples and the rules of the shape.
Mode
stride
Use
Selects points at index intervals, according to the target.
Check
A peak between two sampled points may not appear in the PNG.
Mode
minmax
Use
Chooses the local extremes of sample windows.
Check
Suitable for visual comparison of peaks when the series order allows it.

Target display points uses 6000 by default, Dataset streaming chunk rows uses 5000. The block determines the size of the reads. Missing or invalid rows can be discarded depending on type and mode. Check dropped before interpreting the figure. A calibrated selection compares the canonical data of the series and keeps the original ordinals even when the PNG is reduced.

Comparison on the same source

In the reproducible sample of 14,001 samples (ZIP), with target_points=1200, voltage source in V and abscissa in s, the diagnostics report 14,001 valid rows. With none all of them are used in the presentation. With auto, stride or minmax the test reported 1168 displayed points. Compare the effective mode in the diagnostics: the same count does not imply the same set of points.