Exercises with downloadable data

Reproduce these exercises in the Session. The sensor and grid data are synthetic. The NPL exercise uses a published measurement.

Temperature and power on the same X axis

Download sensori-temperatura.csv (ZIP). Import time in seconds, temperatures in degrees Celsius, power in W, and the dimensionless cycle. In the Scientific dataset 2D row, create a series with time_s and measured_degC on the left axis. Add time_s and heater_W on the right axis. Start Run. In Plots, check that the two Y axes show different units.

The Plots tab shows an XY chart with temperature on the left axis and power on the right axis.
The Plots tab shows an XY chart with temperature on the left axis and power on the right axis.

Rectangle selection and Dataset reuse

Use the same CSV. Enable Scientific dataset 2D – rectangle selection. Bind only measured temperature to the left Y axis. Start Run and draw a rectangle from about 5.4 to 14.6 s and 23.5 to 25.2 °C. Publish the members with Select data… → Graphical area → Keep selected → Create Dataset. The example returns the six samples from 6 to 11 s. In Canonical table, columns v0001 and v0003 retain time and measured temperature. Add a series with those two variables to overlay the derived samples on the original curve. Rerun and check that the segment matches.

The rectangle selects both a time interval and a temperature interval.
The rectangle selects both a time interval and a temperature interval.
The synthetic Dataset table shows the six rows selected by the rectangle.
The synthetic Dataset table shows the six rows selected by the rectangle.

XYZ grid with a color quantity

Download superficie-reticolo.csv (ZIP). Import the three coordinates in mm and the intensity_V column in V. In Scientific dataset 3D, bind X, Y, Z, and C to the four columns. scatter3 produces 25 points. Create a variant and open the 3D preview. Change the camera and use Save High-Resolution Image as Dataset… to save the view as a PNG.

Attenuator S21 measurement