Extract, verify and republish
Isolate a band of the S21 measurement, check every row in the table, and use the new Dataset as the source for a second plot. Reopen the Session afterward to check both objects.
Prepare the NPL measurement
Download npl_s21_misurato.csv (ZIP), a numeric extract from the NPL 0601 VNA measurement. It contains 201 frequencies from 2.5 to 52.5 GHz in 250 MHz steps. insertion_loss_dB is calculated as −20 log10(|S21|), with |S21| = hypot(Re(S21), Im(S21)). Loss increases as magnitude decreases. source_index counts from zero. NPL source on Zenodo, licensed CC BY 4.0.
Import the CSV in Acquisition with ID npl_s21_misurato. Assign Hz to frequency_Hz, dB to insertion_loss_dB, and 1 units to the other two columns. In Analysis → Scientific Dataset Plot, select the Dataset and enable Scientific dataset 2D. With Series, create s21 on Axis → left and bind frequency to X and loss to Y. Run the analysis and select the plot in Plots.

Select and check the band
- Use Data / Variants → Select area. Drag a range from around 9.6 GHz to around 20.1 GHz. In the example, the GUI summary showed 9.58953073–20.1049233 GHz.
- In Select data…, choose the
s21series, Graphical area, and Keep selected. Set New Dataset ID tonpl_s21_banda. - Press Save Selection to save the selection. Press Create Dataset to create the table. When finished, the dialog reports 42 rows from one member.
- Open
npl_s21_bandafrom the Dataset browser and select Canonical table.v0001retains Hz andv0002retains dB. The table begins at 9,750,000,000 Hz and ends at 20,000,000,000 Hz.

The source ordinals are 29–70 inclusive. A row-by-row check gives exactly the original measured values for those ordinals. The losses at the two endpoints are about 3.882784 dB and 3.880592 dB. These values are at the band edges. Use the whole extracted table to find the minimum and maximum.
Republish and reopen
- Return to Analysis. Enable Scientific dataset 2D – rectangle selection and open its Series.
- Create a series with Dataset
npl_s21_banda, Xv0001, and Yv0002on the left axis. Enter a recognizable label, such as “NPL S21, extracted band.” Register the series and run the analysis again. - In Plots, open the second plot. The display can convert Hz to GHz. The table retains Hz.
- Press Save Config and close the application. Restart GX-TXT, use Open Session, and reopen the Dataset in Canonical table and the plot in Plots.

Reuse a Selection with Dataset Extract
In the rectangle exercise, save the selection with Save Selection. In Configuration → Modules → Analysis & Services, select Dataset Extract and press Enable module. In Analysis, find its tab and set the source Dataset as primary.
- Rows → all
- Uses every row of Primary. The example contains 31 rows.
- Rows → selected
- Uses the rows from Dataset selection (Selected/Unselected rows only). In the test Session, the member-based Selection contains six rows from the rectangle.
- Rows → unselected
- Uses the complement of the selection. The sensor example returns 25 rows. Check which filters and members are included in the Selection.
- Variables → all
- Keeps all available source variables.
- Variables → trace
- Projects the result onto the X and Y columns of the trace. Set Trace X variable (Trace mode only) and Trace Y variable (Trace mode only) when required. A member-based Selection also carries its own source bindings.
- Output Dataset ID
- Choose a new identifier for each run. Use Run / recalculate now and the standard Run workflow.

Open rettangolo_selected_trace in the Dataset browser. v0001 retains time in seconds, and v0003 retains measured temperature in °C. Check ordinals 6–11. In Analysis, select these two columns to publish a new series in Scientific dataset 2D. Use the table and derived plot to check that the values match the original samples.
To reuse the range on filtered signal, press Save Selection in Select graph data while channel 1 is the only member. With Dataset Extract → Variables → all, selected returned 201 rows and unselected returned 4,466. Both tables retain the value 1 in v0004. The complement is calculated against the samples that already satisfy the member filter.
Reuse a range-based Selection
To reuse the legacy Selection saved automatically by Select area on a simple XY plot, set Primary to exactly the Dataset that owns the Selection. In the test with 31 samples, the X range saved as sel_001 returned 5 rows with selected and 26 with unselected. Variables → all retains all five columns. For trace, set Trace X variable → v0001 and Trace Y variable → v0003 explicitly. If you leave them blank, Run reports “Trace mode requires X/Y bindings.” When both are set, the analysis publishes the same rows using the two selected columns.