Explore the Plots tab
Plots lists the graphs produced by analyses and the clones saved in the Session. Select a row to see its preview. Use Use to mark the plots you want to include in batch operations.
Open the tab
Open Plots in the main window. The list is empty until you open a Session that contains plots. Use New Session to start or Open Session to resume saved work. Press Refresh to reload the list from the Session when an analysis generates new plots.
Module identifies the provider. plot.dataset is Scientific Dataset Plot, and core.plot_clones is a detached clone. Other modules have their own IDs. Plot is the row title. Use the horizontal scrollbar below the list for long titles and the vertical scrollbar to reach off-screen rows. The preview on the right fits the available space. Select another row to change the image, title, and summary. Double-click the image to open the PNG window.

Set Use and order the rows
- Selection → All
- Set Use to YES for every row. Start here to export or rerender all compatible plots in one operation.
- Selection → None
- Set Use to NO for every row. The current row can still be highlighted and visible in the preview.
- Selection → Toggle
- Flip YES to NO or NO to YES for the current row. Double-clicking a row in the table also changes Use. Select the row first and check the first column after the change.
- Selection → Up / Down
- Move the current row one position in the list. Up on the first row and Down on the last leave the order as it is.
The Session stores Use for registered plots. With Scientific Dataset Plot, a plot output configured in Analysis can be excluded from Run if its row in Plots has Use set to NO. In the test, the job finished with PASS and left the previous XYZ PNG in place. After switching Use back to YES, the same Run updated the plot. Check Use if a successful job leaves the expected figure unchanged. A clone retains its own Use setting. For a PNG available only as a file, the setting applies to the current browser. Clone the PNG to save it as a Session object.

Rerender a plot
- Render → Rerender acts on the current row. Use it after changing presentation settings if the module still has the prepared data it needs.
- Render → Rerender selected starts from the rows with Use set to YES. If every row is set to NO, select at least one plot in the Use column. A provider can also update its related outputs while processing.
- Render → Rerender module starts from the module that produced the current row. Use it when you need to update several plots from the same module.
Check the final message and preview after rerendering. If a new plot type or binding invalidates the cache, run the module from Run to prepare the data again. An earlier PNG can remain available after an error. Check the title, axes, and Graph → Graph info… to identify which render produced it.

Commands when no plots are available
With no plots, Selection leaves the list empty. Rerender requires a row, Rerender selected requires at least one row marked in Use, and Rerender module requires a plot from the module. Select data… is disabled. Row-specific commands may ask you to select a plot first or have no effect. Graphics… and Plot controls help… open even in this state. Import Graph ZIP… requires a Session. Import conf… can already open the JSON file picker. Export conf… requires a loaded presentation draft.