Publish plots from Analysis
Scientific Dataset Plot reads the canonical variables in the Session. Prepare at least one active series for an XY plot. Set the source and coordinate bindings for an XYZ plot.
Import data and enable the module
- Open a Session. In Acquisition, choose the generic CSV reader, add the file, and check the delimiter, header row, and Dataset ID. In Variables, assign units and roles to the columns and import the source.
- In Configuration → Modules → Analysis & Services, select Scientific Dataset Plot. If Enable module appears, enable it. Find the corresponding tab in Analysis.
- Choose the Dataset ID for the primary source. The
primary.nomebindings point to that source. The Source ID field displaysprimary. Remove is disabled because this source is required. To change the source, use Dataset ID. For XY plots, each row in Graph Series also has its own Dataset and X/Y bindings. If you change Primary and Run reports a binding still tied to the old Dataset, realign all listed fields or use auto where available. The check can also flag a previously used configuration for a plot output that is currently disabled.
Choose the plot outputs
In Graphs offered by module, choose the outputs to calculate. Enable all enables them and Disable all disables them. Check the prerequisites for each enabled row before running the analysis.
- Scientific dataset 2D
- Standard XY plot. Open Series and register at least one active series. Configure… controls titles, overall style, and layout. The base file is
01_dataset_xy.png. - Scientific dataset 2D – rectangle selection
- XY plot with rectangle selection. Set its series separately. If no series is active, Run may report
graph plot.dataset.xy_region has no active Graph Series. Add a series or exclude this output from the run. The base file is02_dataset_xy_region.png. - Scientific dataset 3D
- Plot X, Y, and Z as a line, point cloud, or surface, among other types. Bind the three coordinates in the module. Select C or Family when the plot type and Dataset support them. The base file is
03_dataset_xyz.png.
Start and monitor Run
Enable Run / recalculate now for the module. Open Run, use Refresh plan, and check which modules will run. Run enabled analyses starts the enabled analyses. An incompatible or missing input can block preparation. The job log identifies the output and the failed requirement. When you see Selective analysis completed, open Plots and check the new row and plot. For an existing Plot Dataset row, also check Use. In the XYZ test, the job returned PASS with Use set to NO and the output enabled, but the old PNG remained. After setting Selection → Toggle to YES, a new Run produced the expected PNG. If a PNG was already present, compare the title, axes, and timestamp to identify the current render.
In Execution plan, SKIPPED indicates that the module is excluded from the run. BLOCKED signals a missing prerequisite, such as a Primary source without a Dataset ID. PENDING means the module is ready for the initial job check. PASS confirms that the calculation succeeded, and FAILED directs you to the diagnostics in the same panel. Copy log copies the log to the clipboard. During calculation, the message above the progress bar identifies the running module. In the Scripts & Jobs… group, Script Runner… opens the script panel, Job Manager (local / remote)… opens the job view, and Execution help shows execution help. Stop is enabled while a calculation is running. In the test, the state became SKIPPED with reason Run stopped, and the progress bar showed Analysis interrupted.

Reduce the displayed points
The calculation configuration offers Large-dataset presentation reduction, Target display points (approximately, per graph), Auto reduction threshold [valid rows], and Dataset streaming chunk rows. The initial values are 6,000 points, a threshold of 12,000, and a block size of 5,000 rows. auto chooses a method based on the threshold. none keeps every sample in the plot. stride reduces the number of samples at a fixed stride. minmax retains the extrema of each block where the plot type supports it. Set the target based on the useful display density. Compare the rendering with the source table when an extreme feature matters. Display reduction preserves the canonical rows in the Dataset.
Check the point count in the plot and Dataset
Download serie-riduzione.csv (ZIP), a synthetic signal with 14,001 samples. In the series, use time_s in s and level_V in V. With a target of 1,200 and a threshold of 12,000, none kept 14,001 points in the view. stride and minmax each kept 1,168 points. In these conditions, auto selected minmax. The order and choice of points depend on the method. The Dataset retains all 14,001 rows.