Select and publish data

Use Select data… to define which source rows to keep or exclude. Save the Selection or publish a Dataset directly.

Save the selection or publish the table

Save Selection saves the selection reference and its members in the Session. Use it if you want to reuse the Selection with Dataset Extract. Create Dataset creates a new Dataset. Enter a new, readable New Dataset ID. Check the selected mode and operation before proceeding. The Created message reports the ID, row count, and member count. Close closes the dialog.

Spaces in the ID are rejected. If a name is already in use, choose another ID before repeating Create Dataset. With no selected points or no region containing rows, the warning says “Select at least one point or draw an area containing source data.” If you have changed the current row, return to the plot where you started the selection before publishing.

Select graph data uses Graphical area and Keep selected for the temperature series.
Select graph data uses Graphical area and Keep selected for the temperature series.

Open the Dataset in Dataset. In Canonical table, check the units and rows. Schema and provenance shows the structure. Compare traceability columns such as selection_member_id, selection_source_dataset_id, and selection_source_row_ordinal when present. Use the actual canonical IDs to configure the next plot.

Check members with different sources

In Individual points, clicking near a compatible sample uses its source ordinal. Repeated clicks on the same sample keep it only once. If there is no compatible sample within about 12 preview pixels, the dialog reports it. Right-click to finish picking. Of the 96 samples in the exercise, choosing two points returns two rows with Keep selected and 94 with Exclude selected.

On an XY plot with a right-axis series, the X range can extract rows for that member too. In the test, Keep selected returned 27 rows and Exclude selected returned 69. Point picking on the same curve reported that it needed a left Y-axis series with the calibrated units. For multiple members, check the summary after each click. Two clicks on ordinal 12 in two series from the same source produce two rows, one per member. Two sources with compatible X values can use the same range. In the test with Y in mV and V, picking snapped only to the series that matched the active calibration.

An X range can include more than one series. With two series from the same Dataset, each published row retains its member, even when both come from the same ordinal. For two sources with different schemas but X in seconds, publishing produced a long-format table with columns x, y, member_id, source_dataset_id, source_row_ordinal, x_unit, and y_unit. In the test, Y was in mV for one member and V for the other. Before comparing values, read the unit for each row or separate the members and convert to compatible units.

With X in s for one series and ms for the other, the plot can appear, but Create Dataset from a single area requires a conversion for each series. Use a separate selection for each source unit or prepare Datasets with the same X unit. The rectangle uses only left Y-axis series and requires units that match the calibration. If the right-axis series prevents calibration in Plots, see prepare the plot with only the left axis.

Publish a rectangle selection across multiple series

In a rectangle, both coordinates bound the selected samples. In the test, two members from the same Dataset returned 52 rows with Keep selected and 140 with Exclude selected. With two source Datasets in different Y units, mV and V, the plot showed the rectangle but publishing reported a source Y unit mismatch. The same workflow succeeded with both Datasets in mV. Choose the unit before import or convert the data to a new Dataset, then recreate the series before selecting the area.

Extract table samples from a reduced plot

  1. Import serie-riduzione.csv (ZIP). Use time_s in s for X and level_V in V for Y. In Series, set Filter variable → channel, press Refresh values, choose 1 in Filter value, and use Add/update one series.
  2. Use stride, a target of 1,200, a threshold of 12,000, and a block size of 5,000. Publish in Run. After filtering, the view shows 390 of the 4,667 samples from channel 1.
  3. In Plots, draw a range from about 0.3502 to 0.4508 min (21.01–27.05 s). Open Select data… and choose the filtered series and Graphical area. Use Keep selected to publish dense_channel_one_keep. For Exclude selected, use a second ID.
  4. Check for 201 rows with Keep and 4,466 with Exclude. All ordinals belong to channel 1. Of the 201 samples in the range, 17 were plotted and 184 were omitted by display reduction. Publishing includes those 184 samples as well, with time in s and signal in V.

Use Individual points to pick individual samples that appear in the plot. Graphical area looks up source ordinals that satisfy both the filter and the area bounds.