Axes, Scales, Limits, and Ticks

GX-TXT P011-bis · Scientific Dataset Plot 4.4.2

Open Axes… from the Analysis Configure window or from Plots → Presentation → Axes…. Check the output or PNG name at the top before saving.

Axes on the base plot. Scroll to reach the actions and the lower options.
Axes on the base plot. Scroll to reach the actions and the lower options. Enlarge
Field
Use plot-specific configuration
Values and check
Enables the overrides for the current plot. Inherited values follow the general configuration or the representation.
Field
Display unit
Values and check
inherit keeps the current setting. A compatible unit converts the displayed coordinates. Check the limits, the label and the ticks in the new units.
Field
Min / Max
Values and check
Blank keeps the automatic limit. Enter finite limits in the display unit. The requested range and the range actually used can differ because of layout or aspect.
Field
Step
Values and check
Explicit positive value in the displayed units on a linear scale. On native log branches and on the shared X axis the step represents decades. Blank uses the automatic choice.
Field
Format
Values and check
inherit delegates the format. An accepted numeric format such as %.2f changes the generated caption. The field is checked before rendering, with a single numeric conversion at limited precision. X ticks with explicit text take precedence.
Field
Scale
Values and check
inherit, linear or logarithmic depending on the selector. A log scale requires positive coordinates in the domain. The Y sides are independent when configurable.
Field
Minor grid
Values and check
Enables the subdivisions according to the mode. Automatic logarithmic minor ticks follow the scale.
Field
Direction
Values and check
Uses normal or reversed order where the control is available. Reversal changes the visual direction while keeping the references and numeric limits.
Field
2D XY axis aspect
Values and check
Uses automatic mode or equal numeric aspect where allowed: the same pixel distance for one numeric X/Y unit. For a physical comparison, check the units separately. Branches with log or two Y scales do not allow this condition.
Field
Level scales…
Values and check
Opens the level settings for the supported physical quantities, with reference and zero handling. Use a consistent quantity and amplitude base. It is separate from the logarithmic tick scale.

Grid, position and alignment

In Grid and labels, Align Y labels use inherit, 1 or 0. It takes effect when the panels show several Y captions. X+Y grid offers both, vertical, horizontal, none, inherit. Y grid source chooses the side left, right, none or inheritance. A missing side provides no ticks for the grid. Grid color customizes the color of the active grid.

Format offers inherit, auto, %g, %.0f, %.1f, %.2f, %.3f and %.4f. The modes %.nf show n decimals. Use %g for the general numeric format. 2D XY axis aspect offers inherit, auto and xy_equal. Switch to auto if you want a logarithmic scale. The box 3D view, Z axis, Colormap / colorbar and the related scalar are present in the shared dialog. The ordinary XY figure uses X and the Y sides.

Units and domains

To compare s and ms, keep the source column in seconds and choose ms as the X display unit. A limit of 0.5 s corresponds to 500 ms. The same references let you trace back to the rows in the calibrated selection. An incompatible conversion requires another unit or another axis. After manually changing the X unit, check the explicit range. shared_x_axis_set converts the saved ticks, while the numeric Min and Max values need a separate update to keep the same physical extent. Set positive limits before Log, especially with ranges or uncertainties that reach zero.

Text X ticks

  1. Open Edit pairs…. Position is an X coordinate. Caption is single-line text.
  2. Add pair adds a row. Select a pair to use Update selected and Remove. Move up and Move down change the order in the dialog. Clear / automatic prepares the removal of the pairs. An empty list re-enables automatic numeric ticks.
  3. Use pairs transfers the content to the Axes draft. Cancel closes the editor without applying the pairs draft. In Axes, Save registers the configuration, Save and rerender plot registers and regenerates the file, Restore automatic returns the plot to automatic behavior, Cancel discards the editor changes.

The corresponding PlotSpec fields are tick_positions and tick_labels, both strings separated by semicolons. Enter them together with 1–1024 pairs and finite numeric positions in the display unit. The same numeric position repeated is rejected, even when written in different formats. A caption requires non-empty single-line text, up to 256 characters and 1024 UTF-8 bytes, and cannot contain a semicolon. A tick outside the saved limits can stay in the specification and be out of view. A log scale requires positive positions. Histogram and box plot have derived axes and reject the X pairs of the bar exercise.

A complete example is available with five aggregated frequencies and a second example with non-equidistant positions. Shared X ticks must be consistent across panels.

Level scales

From Axes, open Level scales…. The relevant rows depend on the output and on the active Y sides. Choose linear for linear values, dB for a relative logarithmic measure, dBFS for decibels relative to full scale, or FS to express the linear ratio to full scale. Quantity distinguishes amplitude and power. For amplitude, specify the base, for example peak or rms. Enter a positive reference and a consistent unit. missing and negative_infinity change how zeros are represented. Save, or save and regenerate, to check the level transformation.

Level scales configuration with dBFS on the signal side.
Level scales configuration with dBFS on the signal side. Enlarge