Exploring UV/Vis Spectra and Time Series

GX-TXT DEV112 P011-bis

Explore UV/Vis spectra and time series, compare the family members and check the published variables.

GX-TXT P011-bis · module 1.0.3. UV/Vis Spectrum and Time-Series Exploration displays and prepares a UV/Vis absorbance spectrum or a family with a time parameter. It keeps results in separate Datasets for the spectrum and the time response.

Prepare single example and family

From Session → New Session → Generate Session creates a Standalone Session with Manchester MXene UV/Vis. In Datasets check uvvis.sample.7_1 and uvvis.blank in Preview and Metadata. James Bird’s data are in nm and absorbance, CC BY 4.0. Manchester collection.

For the time branch, follow the Python Script path for the canonical family. uvvis.manchester.elapsed_demo reuses the ten spectra with a synthetic time index from 0 to 90 s in 10 s steps. The differences between samples reflect different concentrations. The time response is an exercise in using the GUI and the Datasets.

Select workflow and treatment

In Configuration → Modules → Analysis & Services search for UV/Vis Spectrum and Time-Series Exploration, read Health and press Enable module. Tick Run / recalculate now in the tab Analysis.

Workflow
single_spectrum, the default, receives the spectrum uvvis.sample.7_1. time_series receives the family uvvis.manchester.elapsed_demo and uses the time coordinate of the members.
Dataset sources
Select the spectrum or the family in primary. blank identifies the reference absorbance for the correction, for example uvvis.blank. + Add source creates additional aliases. Remove releases an input or removes the added alias. For these Runs the expected roles are enough.
Analytical wavelength [nm]
Value to read in the single response or in each time member. The default and the test value is 322 nm.
Blank correction
none leaves the ordinate as it is. subtract_blank_absorbance subtracts the blank and requires the source blank with an overlapping domain.
Baseline method
none leaves the baseline. linear corrects a line, polynomial a polynomial trend. The correction comes before normalization.
Smoothing method
none leaves the points unchanged. moving_mean computes a local mean. local_polynomial fits a local polynomial, also on non-uniform coordinates. savitzky_golay uses a polynomial filter on a uniform grid. The Manchester members allowed the test with window 11.
Smoothing window (odd)
Odd width of the treatment, initially 9. Inactive for none. Wider windows reduce fluctuations and can alter narrow peaks.
Normalization
none leaves the scale, unit_vector divides by the norm, mean_center_unit_vector first centers the values and then applies the norm. Compare the curves before interpreting differences in absolute absorbance.
Minimum peak prominence
Minimum threshold for peak prominence relative to the local background in the search. Default 0.005. Lowering it brings out weaker peaks.
time_series workflow with blank subtraction, polynomial baseline and 11-point Savitzky–Golay.
time_series workflow with blank subtraction, polynomial baseline and 11-point Savitzky–Golay.

Compare single spectrum and time response

For the first Run choose single_spectrum and none in the treatments. Select uvvis.sample.7_1, update the plan in Run and start the selective analysis. In the Dataset browser you will see .uvvis.original_absorbance, .uvvis.processed, .uvvis.peaks and .uvvis.selected_response.

For the second choose time_series and the teaching family. Try baseline linear, moving_mean, unit_vector and blank none. Then compare polynomial, local_polynomial or savitzky_golay with window 11, mean_center_unit_vector and blank subtraction. The test Runs publish .uvvis.processed_family and .uvvis.time_response. In Results open uvvis_exploration_report.md. In Datasets open Preview, Metadata and Canonical table. The response contains the individual values over time, the processed family keeps the spectral points.

Response at 322 nm for the ten members, ordered by the teaching time of each spectrum.
Response at 322 nm for the ten members, ordered by the teaching time of each spectrum.

Generate and present the plot

In Graphs offered by module enable UV/Vis processed spectrum or time response. Enable all selects the plots offered, Disable all excludes them. Configure… edits the single proposal and Module graphics… opens the module’s graphics configuration. After the Run, from Plots choose the spectrum plot or the time response. Look for the editable row Plot p… to change a title through Presentation → Title and labels…, regenerate with Render → Rerender selected and open Graph → Open PNG 1:1.

Plot of the UV/Vis response at 322 nm, with a teaching time axis.
Plot of the UV/Vis response at 322 nm, with a teaching time axis.