Time-Dependent FFT
GX-TXT DEV112 P011-bis
Follow how the spectrum changes over time with successive windows and compare the results obtained with different resolution settings.
Enable the module and choose a Session
In Configuration → Modules → Analysis & Services select Time-Dependent FFT (analysis.time_dependent_fft 1.3.3 in the P011-bis test). With Health Available and state CORE / OFF uses Enable module. In Analysis select Run / recalculate now to include the module.

Use the procedure FFT Example to generate a Session with the Generator fft_example 1.0.0, acquire fft_example.csv as guida.fft.misura and assign seconds to time_s and unit 1 to signal. In Preview check the 1024 samples. Follow the Window Set procedure to save Quattro finestre FFT, size and step 256 samples, Drop. The lab produces four consecutive windows and uses the same grid for the time-frequency comparison.

Configure analysis, axis and representation
In Dataset sources choose guida.fft.misura as primary. For that role the command Remove is disabled. In Input variable bindings bind primary.time_s to Time / temporal variable and primary.signal to Signal variable. The selectors show auto and the available variables. The time must be uniform and consistent with the Window Set. For Temporal Window Set choose tset_001 — Quattro finestre FFT. None leaves the required set missing.
- Control
- Run mode
- Choices and effect
auto, the default, decides based on the cache.recalculaterebuilds the results.render_onlygenerates plots and exports from a compatible result. If mismatch_parameter_fingerprint, userecalculateorautoappears for the new parameters. After the dB computation, a Run with identical scientific parameters andrender_onlyreused the cache.
- Control
- FFT weighting window
- Choices and effect
rectangularapplies a constant weight,hann, the default, tapers the ends,hammingkeeps a residual weight at the ends,blackmanattenuates the side lobes further,blackman_harrisincreases side-lobe suppression with a wider main lobe,flat_topfavors the amplitude estimate near the peak.
- Control
- Pre-FFT detrend / DC handling
- Choices and effect
nonekeeps the signal,mean, the default, removes the mean per window andlinearsubtracts the estimated trend.
- Control
- NFFT mode / Explicit NFFT
- Choices and effect
autoderives the number of points from the windows.explicituses the number entered, proposed as 4096. Specify a number that contains all the samples of the window. In the lab 256 produces 129 bins at 4 Hz, 512 produces 257 bins at 2 Hz through zero-padding.
- Control
- Spectral representation
- Choices and effect
amplitude, the default, uses the unit of the signal.psduses its square per Hz.amplitude_dbuses a logarithmic representation of the amplitude with the reference given in the report. The choice applies to the Dataset created and to the view.
- Control
- Parallel workers
- Choices and effect
auto, the default, delegates the choice,serialuses the serial path, a positive integer requests an explicit number. The report distinguishes request, effective workers and state.
- Control
- Separate per-window data export
- Choices and effect
none, the default, avoids separate numerical files.selected_windowsuses the same choice as Window spectrum plots.all_windowsrequests one file per window. The main Dataset still contains the whole grid.

Open the result and tell it apart from the views
In Run check the Dataset in the plan and start the Analysis. Wait for Selective analysis completed and open guida.fft.misura.tdfft.v0002.tset_001 from Dataset → Preview. Use Open Dataset → Canonical table. With amplitude and NFFT 256 you get 516 rows, 129 frequencies for four windows. time is the midpoint of the first and last coordinate of the window, in seconds. frequency is in Hz, window_index numbers the windows and amplitude gives the spectral value. The value columns and their units depend on the representation. In Metadata and Technical details read origin, contract table.generic, identity and shape of the table.
The Datasets with .display. in the name are used by the plots. Display limits and any dense reduction do not reduce the main table. In Results read time_dependent_fft_report.txt for effective parameters, window_plot_index.txt for any separate plots and split_export_index.txt for the separate numerical files.

Choose map, surface and per-window spectra
In Graphs offered by module the separate checkboxes select Time-frequency overview (map with X time, Y frequency, color value) and Time-frequency 3D surface (height Z as value), both on at first, and Window spectrum plots, initially off. Use Enable all or Disable all to change all the checkboxes. Configure… opens the parameters of the selected plot. Module graphics… concerns the common style. Variants… and Series… are the controls for the variants and for the series of the individual plots.
For map and surface, Plot title sets the title. X-axis label and Y-axis label use auto for time and frequency in the display units. Colorbar label on the map and Z-axis label on the surface use auto for quantity and unit. Write a text label to replace it.
- Temporal scope
all, the default, uses all windows for the view.selecteduses those chosen in Window spectrum plots.- Maximum displayed time windows / Maximum displayed frequency bins
- Maximum displayed per dimension. 0 keeps all samples of the dimension. The map starts from 256 and 2048, the surface from 128 and 1024.
- Display reduction for dense grids
peak, the default for the map, preserves the local maximum.mean, the default for the surface, shows the group mean.- Additional output format
none, the default, leaves the PNG,pdforsvgadd a file.


For Window spectrum plots, Plot title, X-axis label and Y-axis label describe the spectra with frequency on the abscissa. auto derives quantity and unit. For Windows to plot/export choose a mode:
alluses all windows.index_rangeuses the first index in First window index (1-based, default 1) and the last in Last window index (0 up to the end, default value).explicit_listuses Explicit window list. Enter a list such as1,3or ranges such as1,5,12-20.time_rangeuses Start time and End time in the source unit. An empty field means an open end.
Maximum displayed frequency bins starts from 8192, 0 uses all available bins. Stable preview artifact offers first_selected, the default, or overlay_selected to overlay the selected spectra. Legend labels offers none, index, time and index_time. Write one separate plot file per selected window, initially on, creates one file per chosen spectrum. Individual plot format accepts png (default), pdf or svg. Individual plot basename starts from fft_window. In Individual title template uses {index}, {member_id} and {time} to include the window data. Additional preview output format uses none, pdf or svg. Close closes the dialog. Recalculate, or use the cache when compatible.
To repeat the test, enable the per-window plots, choose explicit_list with 1,3, overlay_selected, index_time, individual files svg and numerical export selected_windows. The computation with PSD and NFFT 512 produced two SVGs and two CSVs, registered in the indexes, besides the map with the updated title. A second run with amplitude_db, all_windows and auto produced all four CSVs. In Plots open the plot row to inspect the view.


Adjust axes, projection and color
Configure… → Axes… opens Axes / grid / 3D / color. Use plot-specific configuration applies overrides to the current view. The axes available in the dialog are X, Y Left, Y Right and Z. Fields that concern an axis or a view type that is absent have no effect.
- Display unit
inheritinherits,autouses the automatic choice andsourcedisplays in the source unit. Limits are expressed in the unit shown.- Min / Max / Step
- Empty inherits or leaves the automatic value. Enter lower limit, upper limit and tick step consistent with the scale.
- Format
inheritinherits,autochooses the format,%guses significant digits and%.0fto%.4fforce zero to four decimals respectively.- Scale / Minor grid
inherit,linearorlog; for log use positive coordinates.Offleaves the minor grid off,Autodelegates the subdivisions when the plot type supports it.- Z label / Z grid
- Z-axis label and grid
inherit,onoroffin the relevant view. - 2D XY data aspect / 3D view
inheritinherits,autofits andxy_equaluses the same spatial scale on X and Y. In 3D Azimuth and Elevation orient the camera, Projection selectinherit,orthographicorperspective. Aspect addsdata_equalfor all dimensions andmanualfor the three ratios in Manual X;Y;Z.- Colormap / Colorbar
- Colormap names the palette, initially
inherit. Colorbar usesinherit,0to hide or1to show. Color unit inherits, usesautoorsource. Label replaces the text and CLim min and CLim max set the interval represented by the palette. - Plot background
- Choose with Choose…, restore inheritance with Inherit or select Transparent. The export format determines how transparency appears.
- Align Y labels / XY grid
- Alignment
inherit,1or0. Gridboth,vertical,horizontal,noneorinherit. Select Y grid sourceinherit,left,rightornone. Grid color sets the color.
Save stores the configuration, Save and rerender plot also requests a new rendering, Restore automatic returns to the automatic proposals, Cancel exits without applying the draft. Level scales… concerns the level scale available for the active plot type.

In Level scales…, choose the relevant Axis row, for example Y1 or Y2 for a view with two ordinates. In Scale, linear keeps the quantity, dB refers it to an explicit value, dBFS uses the level in decibels relative to full scale and FS uses the ratio to full scale. In Quantity enter amplitude for the 20 log formula or power for the 10 log formula. Basis distinguishes peak from rms. Empty fields are the initial state of the linear row. Reference and Reference unit declare a consistent value and unit, required to use an explicit reference. In Zero choose missing, the default, to treat zero in the log as missing data, or negative_infinity to represent it with the logarithmic limit. Use Save or Save and rerender. The change concerns the representation. If the column already contains amplitude_db, keep the linear scale to read those levels.