GX-TXT-v3: IR Remote Control Tester – Circuit Schematic and Assembly

PCB GX-TXT-v3 del ProvaTelecomando IR assemblato e pronto per la caratterizzazione

GX-TXT-v3 is a compact IR remote control tester with adjustable gain and sensitivity, 20-second auto-off, PCB layout, and assembly details.

#2N3904 #analog electronics #BAT54 #circuit schematic #circuit testing #Darlington transistor #DIY electronics #electronics project #GX-TXT #GX-TXT V3 #HOLD circuit #infrared detector #infrared remote control #IR receiver #IR Remote Control Tester #IR tester #LTspice #NE555 #PCB assembly #PCB design #remote control testing #sensitivity control #transistor amplifier

Published by giux · No comments

GX LII-2 – Lab Log: Bode Measurement Campaign on Resistive Dividers

Quaderno di laboratorio con frequenze, valori di Vgen e acquisizioni A/B della campagna di misure Bode sui partitori resistivi.

GX LII-2 resistive-divider campaign: Bode measurements, A/B compensation, injection transfer, and FFT analysis in GNU Octave.

#A/B compensation #Bode measurements #calibration bench #common-mode noise #DUT impedance #FFT analysis #frequency response #GNU Octave #GX LII-2 #harmonic analysis #injection transfer #injection transformer #Loop Gain #LTspice #measurement residual #oscilloscope measurements #resistive dividers #spectral analysis

Published by giux · No comments

GX LII-2 – Lab Log: Bode Measurements and GNU Octave Processing

GX LII-2 lab log: Bode measurements, A/B compensation, harmonic analysis, clipping diagnostics, and GNU Octave automation.

#A/B measurement #Bode measurements #clipping detection #frequency response #gain crossover frequency #GNU Octave #GX LII-2 #harmonic analysis #injection transformer #Loop Gain #LTspice #measurement automation #oscilloscope measurements #phase crossover frequency #THD #waveform distortion

Published by giux · No comments

Self-Built Injection Transformer: First Loop Gain Measurements and Calibration Test Bench

Self-built injection transformer for Bode and loop-gain measurements, with calibration bench, GNU Octave processing, and LTspice comparison.

#analog electronics #Bode plot #calibration bench #control loop #DIY transformer #EE13 core #electronics measurement #feedback loop #ferrite transformer #frequency response #frequency response measurement #function generator #injection transformer #laboratory instrumentation #Loop Gain #loop gain injection #loop gain measurement #LTspice #oscilloscope measurement #PC40 ferrite #power supply stability #signal injection #SPICE simulation

Published by giux · No comments

Ethical Eating in the City: Choices, Sustainability and Science

Ethical eating in the city: sustainable choices, local food, biodiversity, minimal packaging and emerging alternatives from science.

#animal welfare #biodiversity #conscious consumption #cruelty-free food #cultivated meat #environmental impact #ethical eating #ethical food choices #farmers markets #food packaging #food sustainability #legumes #local food #low-impact food #microalgae #mindful cooking #mycoprotein #plant proteins #plant-based diet #precision fermentation #seasonal food #sustainable agriculture #sustainable diet #sustainable food #sustainable living #urban sustainability #vegetarian diet #whole grains #zero waste

Published by Sarci Vincentini · No comments

The Stolen Identity Card

A stolen identity card, old photographs and a clerk’s unexpected decision become a brief reflection on memory and identity.

#aging #bureaucracy #civil registry #COVID era #everyday stories #identity card #identity theft #life stories #memory and identity #Milan #Municipality 3 Milan #nostalgia #passport photos #personal identity #personal memories #personal reflection #public administration #stolen documents #stolen identity card #Via Sansovino

Published by Sarci Vincentini · No comments

High Fidelity or Placebo? The Mystery of Frequencies We (Maybe) Can’t Hear

High-resolution audio goes beyond the CD standard, offering sample rates of up to 192 kHz and 24-bit depth. While some listeners praise its greater naturalness and detail, others question the practical value of frequencies above 20 kHz. Scientific studies and psychoacoustic tests have produced conflicting results, fueling an ongoing debate over perceived quality, the limits of human hearing, and possible technical distortions.

#192 kHz audio #20 kHz #96 kHz audio #ADC #audio bandwidth #audio engineering #audio measurements #audio reproduction #audio sampling #audiophile audio #DAC #digital audio #electronics #frequency response #hearing range #hi-res audio #High-resolution audio #human hearing #Nyquist theorem #psychoacoustics #sample rate #sound perception #ultrasonic audio #ultrasonic frequencies

Published by giux · No comments