14. The 2D21 in objects, schematics and catalogs

What can be established by looking at a specimen, following the wiring of a television set or reading a manufacturer’s plate? The sources collected here make it possible to move from the physical identification of the tube to the electrical conditions under which its curves were plotted.

Sources examined on this page

Zenith and Giux-Lab. Following the light to the solenoid

The Zenith manual describes the remote control from the point of view of whoever has to adjust or repair the television. The block diagram makes it possible to follow the four sensors separately. Illuminating PC-1 brings in V1 for the power supply, while PC-4 acts on V2 for muting. Both are 2D21s. The other two photocells drive the sections of the 6BX7GT to select the direction of the motor. The designations of the schematic can be found in the photograph of the chassis. This correspondence unambiguously identifies the two tubes whose firing has to be explained.

The reconstruction on Giux-Lab adds a reading of the electrical path. The cadmium sulfide sensor varies its resistance and the sensitivity control sets the resting bias. To calculate the margin between ambient light and command one therefore needs the current that the grid draws from the sensor and the position of the threshold with the shield connected to its network. The switching observed on the television proves that the whole chain worked. On its own it leaves undetermined which voltage G1 reached.

Zenith, operating and service manual, pp. 4–9 · Giux-Lab, reconstruction of the receiver

Eric Barbour’s photograph and the two museum specimens

Barbour’s photograph places the miniature bulb beside a GE hydrogen thyratron for pulse service. The difference in scale helps in reading the following pages: both belong to the thyratron family, but an experimental figure acquires meaning only once the type has been identified. The Australian record holds precisely an RCA 2D21, notes its 6.3 V indirect heating and gives the dimensions of the object. The photograph makes it possible to recognize bulb and pins when the tube is mounted in a chassis.

The Smithsonian item answers a chronological question. Besides the military designation JRC-2D21 there is the packaging with US Navy acceptance in April 1945. This is a documented date for a particular specimen. It makes it possible to place the type before the Zenith receiver without attributing to the acceptance date the meaning of a date of invention.

Eric Barbour, photograph record · Museums Victoria, ST 28272 · Smithsonian, 1986.0794.056

Museo Edelpro. How to follow the 2D21 in industrial listings

The record links the 2D21 to the 2050 as an all-glass miniature version and indicates two distinct registrations. It attributes the 2D21 to RCA, RMA release 378 of April 1944, and to GE the registration 1031 of the high-reliability version 5727. It also records the designations 2D21W, CV797 and EN91. These cross-references explain why a search limited to the string “2D21” misses part of the British documentation and of the industrial versions. The record is a secondary source for the registrations. The reference to the RMA release makes it possible to trace the primary document.

Museo Edelpro, record 5727/2D21W

General Electric. What a curve of the family represents

In the conduction plate you choose an anode current and follow the trace as the G1 voltage with respect to the cathode changes. The reading therefore describes the current demanded of the grid source while the anode load fixes the state of the discharge. One way to compare two curves is to choose the same G1 voltage and read the vertical gap. Another is to look, for each one, for the voltage at which the net current changes sign. The first comparison measures a change in current, the second a shift in voltage.

The GE 5 mA curve extends the documentation towards currents lower than those of the Sylvania family reproduced here. In the quantitative analysis on page 12 it is precisely this section that stands out after normalization. A law proportional to anode current must therefore also be checked at the low end. The capacitance between G1 and anode given in the same data sheet serves instead to interpret fast edges. Good agreement with the static curves leaves the capacitive contribution to be checked.

General Electric, 2D21 Engineering Data

Sylvania. The meaning of the four 2D21 plates

Pages 2 and 4 both describe firing, but change the circuit and the question. On page 2 the anode is on DC, the grid resistance is 1 MΩ and the curve parameter is the shield voltage. On page 4 the manufacturer moves to AC, fixes the shield at zero and draws bands for two resistances of the control network. The reader can therefore look on one plate for the shift of the average threshold produced by G2, and on the other for the operating range to be expected for their own source impedance.

Pages 3 and 5 give the current at the terminal. Before firing, the anode voltage distinguishes the curves and each one stops at firing. Once the discharge has started, the parameter becomes the anode current, from 25 to 300 mA. Moving from one to the other changes both the current scale and the physical condition. In a simulation of the Flash-Matic this determines how much the sensor is loaded before the command trips and how much current can flow through the same network afterwards.

Sylvania, Engineering Data Service, pp. 2–5

Mullard and Philips. The grids in industrial handbooks

On the same EN91 page, Mullard brings together three tests that could be mistaken for sections of a single surface. In graph 117 one looks for the critical voltage with an imposed shield voltage. In 118 one reads the control current while the anode blocks. In 119 one measures current collection while the anode conducts. To move from the end point of a curve in 118 to a curve in 119 one also needs to know the load, which will determine the current after firing.

Philips explains the practical meaning of the small grid current of the PL2D21. A vacuum photocell can drive it directly, but the leakage of the socket must stay small compared with the current to be detected. On AC the wiring capacitance between anode and grid also matters. Section 7 describes the rare-gas tetrode, the indirectly heated cathode and a preheating of about 20 s. Among the typical characteristics are the nominal control ratios of 250 and 1000, measured with specific conditions on the other grid. The handbook thus links geometry, mounting and the actual sensitivity of the circuit.

Mullard, EN91, graphs 117–119 · Philips, Thyratrons for Modern Industry, ch. 7

Schure. From the construction drawing to the critical characteristic

The RCA drawing reproduced in figure 27 makes it possible to locate the shield around the cathode and the control grid and to follow the path through the baffles. Figure 18 changes the scale of observation and sets the critical characteristic of an 884 beside the average one of a 2D21. On the second graph the handbook specifies 2 MΩ in the grid network. Before deriving a slope, both axes of each panel must be read in volts. A tangent on the 2D21 changes along the curve. A control ratio derived at one point therefore has a local domain. The CiNii record identifies the monograph, while the drawing and curves come from the pages of the handbook.

Schure, Gas Tubes, fig. 27 · Schure, §§ 22–23 and fig. 18 · CiNii catalog, identification of the edition

Wisconsin. The same tube as an electron-scattering chamber

The university handout that preserves the 2D21 data also proposes a use very different from relay control. It varies the energy of the electrons in the xenon and compares the collected currents to reconstruct how the transmission probability changes. The transmission maximum signals a minimum in scattering. The analysis also requires a correction for the contact potential difference. On the pages devoted to the experiment the reader thus finds an atomic physics experiment. The control ratios cited on page 5 of this review come from the attached technical data. Using the two parts of the document for their respective observables avoids mistaking the transmission maximum for a firing threshold.

University of Wisconsin, Physics 407, Ramsauer–Townsend Effect

#2D21 #characteristic curves #electron tube #Flash-Matic #GE datasheet #General Electric #grid current #SPICE #thyratron #vacuum tubes

Other steps of this project